Cargando…

Efficacy and Safety of Sutureless Trabeculectomy with Using Porous Collagen (Ologen) in Management of Glaucoma Patients

PURPOSE: This study aims to investigate the safety, efficacy and feasibility of sutureless trabeculectomy using a porous collagen matrix that contains a connected porous structure (Ologen) in the control of intraocular pressure (IOP) in glaucoma patients. METHODS: The study includes 25 eyes from 24...

Descripción completa

Detalles Bibliográficos
Autores principales: Elbably, Ahmed, Rezq, Haytham, ElDakkak, Mohamed, Sepetis, Anastasios E, Othman, Tageldin M
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Korean Ophthalmological Society 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8357608/
https://www.ncbi.nlm.nih.gov/pubmed/34162185
http://dx.doi.org/10.3341/kjo.2021.0044
_version_ 1783737165812858880
author Elbably, Ahmed
Rezq, Haytham
ElDakkak, Mohamed
Sepetis, Anastasios E
Othman, Tageldin M
author_facet Elbably, Ahmed
Rezq, Haytham
ElDakkak, Mohamed
Sepetis, Anastasios E
Othman, Tageldin M
author_sort Elbably, Ahmed
collection PubMed
description PURPOSE: This study aims to investigate the safety, efficacy and feasibility of sutureless trabeculectomy using a porous collagen matrix that contains a connected porous structure (Ologen) in the control of intraocular pressure (IOP) in glaucoma patients. METHODS: The study includes 25 eyes from 24 patients that met the inclusion criteria. All eyes underwent trabeculectomy with the Ologen implant that provides a space with a dynamic and physiological aqueous reservoir system. The operation was considered successful if IOP is <15 mmHg without need of IOP-lowering drops at 18 months of follow-up. RESULTS: The target IOP was achieved in 21 out of the 25 eyes (84%), the remaining four eyes all had an IOP of 16 mmHg at 18 months. Short-term complications consisted of seven cases of bleb leakage treated with bandage contact lens and one case of mild choroidal effusion which resolved after observation alone. CONCLUSIONS: We can conclude that this technique can provide safety, effectiveness and short learning curve for ophthalmology trainees with lower incidence of perioperative and postoperative complications. Further studies may be required to prove stability and long-term efficacy in management of glaucoma patients.
format Online
Article
Text
id pubmed-8357608
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Korean Ophthalmological Society
record_format MEDLINE/PubMed
spelling pubmed-83576082021-08-16 Efficacy and Safety of Sutureless Trabeculectomy with Using Porous Collagen (Ologen) in Management of Glaucoma Patients Elbably, Ahmed Rezq, Haytham ElDakkak, Mohamed Sepetis, Anastasios E Othman, Tageldin M Korean J Ophthalmol Original Article PURPOSE: This study aims to investigate the safety, efficacy and feasibility of sutureless trabeculectomy using a porous collagen matrix that contains a connected porous structure (Ologen) in the control of intraocular pressure (IOP) in glaucoma patients. METHODS: The study includes 25 eyes from 24 patients that met the inclusion criteria. All eyes underwent trabeculectomy with the Ologen implant that provides a space with a dynamic and physiological aqueous reservoir system. The operation was considered successful if IOP is <15 mmHg without need of IOP-lowering drops at 18 months of follow-up. RESULTS: The target IOP was achieved in 21 out of the 25 eyes (84%), the remaining four eyes all had an IOP of 16 mmHg at 18 months. Short-term complications consisted of seven cases of bleb leakage treated with bandage contact lens and one case of mild choroidal effusion which resolved after observation alone. CONCLUSIONS: We can conclude that this technique can provide safety, effectiveness and short learning curve for ophthalmology trainees with lower incidence of perioperative and postoperative complications. Further studies may be required to prove stability and long-term efficacy in management of glaucoma patients. Korean Ophthalmological Society 2021-08 2021-06-21 /pmc/articles/PMC8357608/ /pubmed/34162185 http://dx.doi.org/10.3341/kjo.2021.0044 Text en © 2021 The Korean Ophthalmological Society https://creativecommons.org/licenses/by-nc/3.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/ (https://creativecommons.org/licenses/by-nc/3.0/) ) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Elbably, Ahmed
Rezq, Haytham
ElDakkak, Mohamed
Sepetis, Anastasios E
Othman, Tageldin M
Efficacy and Safety of Sutureless Trabeculectomy with Using Porous Collagen (Ologen) in Management of Glaucoma Patients
title Efficacy and Safety of Sutureless Trabeculectomy with Using Porous Collagen (Ologen) in Management of Glaucoma Patients
title_full Efficacy and Safety of Sutureless Trabeculectomy with Using Porous Collagen (Ologen) in Management of Glaucoma Patients
title_fullStr Efficacy and Safety of Sutureless Trabeculectomy with Using Porous Collagen (Ologen) in Management of Glaucoma Patients
title_full_unstemmed Efficacy and Safety of Sutureless Trabeculectomy with Using Porous Collagen (Ologen) in Management of Glaucoma Patients
title_short Efficacy and Safety of Sutureless Trabeculectomy with Using Porous Collagen (Ologen) in Management of Glaucoma Patients
title_sort efficacy and safety of sutureless trabeculectomy with using porous collagen (ologen) in management of glaucoma patients
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8357608/
https://www.ncbi.nlm.nih.gov/pubmed/34162185
http://dx.doi.org/10.3341/kjo.2021.0044
work_keys_str_mv AT elbablyahmed efficacyandsafetyofsuturelesstrabeculectomywithusingporouscollagenologeninmanagementofglaucomapatients
AT rezqhaytham efficacyandsafetyofsuturelesstrabeculectomywithusingporouscollagenologeninmanagementofglaucomapatients
AT eldakkakmohamed efficacyandsafetyofsuturelesstrabeculectomywithusingporouscollagenologeninmanagementofglaucomapatients
AT sepetisanastasiose efficacyandsafetyofsuturelesstrabeculectomywithusingporouscollagenologeninmanagementofglaucomapatients
AT othmantageldinm efficacyandsafetyofsuturelesstrabeculectomywithusingporouscollagenologeninmanagementofglaucomapatients