Cargando…
Efficacy and Safety of Sutureless Trabeculectomy with Using Porous Collagen (Ologen) in Management of Glaucoma Patients
PURPOSE: This study aims to investigate the safety, efficacy and feasibility of sutureless trabeculectomy using a porous collagen matrix that contains a connected porous structure (Ologen) in the control of intraocular pressure (IOP) in glaucoma patients. METHODS: The study includes 25 eyes from 24...
Autores principales: | Elbably, Ahmed, Rezq, Haytham, ElDakkak, Mohamed, Sepetis, Anastasios E, Othman, Tageldin M |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Korean Ophthalmological Society
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8357608/ https://www.ncbi.nlm.nih.gov/pubmed/34162185 http://dx.doi.org/10.3341/kjo.2021.0044 |
Ejemplares similares
-
Deep Sclerectomy with Porous Collagen in Open-angle Glaucoma, Short-term Study
por: Elbably, Ahmed, et al.
Publicado: (2018) -
Comparison of outcomes of trabeculectomy with mitomycin C vs. ologen implant in primary glaucoma
por: Senthil, Sirisha, et al.
Publicado: (2013) -
Unilateral surgically induced Necrotizing Scleritis after trabeculectomy with Ologen in a patient with pigmentary glaucoma()
por: Shalaby, Usama, et al.
Publicado: (2016) -
Ologen implant versus mitomycin C in combined trabeculectomy and phacoemulsification
por: Paul, Chandrima, et al.
Publicado: (2022) -
Ologen implant versus mitomycin-C for trabeculectomy: A meta-analysis
por: Song, De-Sheng, et al.
Publicado: (2019)