Cargando…
Analysis of risk factors associated with flexor pollicis longus injury after volar plating of distal radius fractures
OBJECTIVE: This study was performed to analyze the risk factors associated with flexor pollicis longus (FPL) attrition or rupture after volar plating of distal radius fractures. METHODS: Three hundred thirty-eight patients with distal radius fractures were included in this retrospective study. Univa...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
SAGE Publications
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8358517/ https://www.ncbi.nlm.nih.gov/pubmed/34369195 http://dx.doi.org/10.1177/03000605211031438 |
_version_ | 1783737357731627008 |
---|---|
author | Lv, Yang-Xun Chen, Mang-Mang Su, Chen-Xian Ye, Hao-Nan Yang, Jie Li, Jing |
author_facet | Lv, Yang-Xun Chen, Mang-Mang Su, Chen-Xian Ye, Hao-Nan Yang, Jie Li, Jing |
author_sort | Lv, Yang-Xun |
collection | PubMed |
description | OBJECTIVE: This study was performed to analyze the risk factors associated with flexor pollicis longus (FPL) attrition or rupture after volar plating of distal radius fractures. METHODS: Three hundred thirty-eight patients with distal radius fractures were included in this retrospective study. Univariate analysis and multivariate logistic regression analysis were performed to predict risk factors. RESULTS: Univariate analysis showed that sex, volar tilt, the Soong grade, the plate-to-critical line distance (PCLD), the plate-to-volar rim distance (PVRD), and the time of plate removal were significantly associated with FPL attrition or rupture. Multivariate logistic regression analysis demonstrated that decreased volar tilt, Soong grade 2, PCLD of >2 mm, PVRD of <3 mm, and plate removal at ≥1 year were the risk factors significantly associated with FPL attrition or rupture. CONCLUSIONS: Reduced volar tilt, Soong grade 2, PCLD of >2 mm, and PVRD of <3 mm appear to be risk factors that are significantly associated with FPL attrition or rupture. The findings of this study also suggest that the risk of tendon rupture is lower if a Soong grade 2 plate is removed, the PCLD is >2 mm, the PVRD is <3 mm, or reduced volar tilt is achieved earlier (at <1 year). |
format | Online Article Text |
id | pubmed-8358517 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | SAGE Publications |
record_format | MEDLINE/PubMed |
spelling | pubmed-83585172021-08-13 Analysis of risk factors associated with flexor pollicis longus injury after volar plating of distal radius fractures Lv, Yang-Xun Chen, Mang-Mang Su, Chen-Xian Ye, Hao-Nan Yang, Jie Li, Jing J Int Med Res Retrospective Clinical Research Report OBJECTIVE: This study was performed to analyze the risk factors associated with flexor pollicis longus (FPL) attrition or rupture after volar plating of distal radius fractures. METHODS: Three hundred thirty-eight patients with distal radius fractures were included in this retrospective study. Univariate analysis and multivariate logistic regression analysis were performed to predict risk factors. RESULTS: Univariate analysis showed that sex, volar tilt, the Soong grade, the plate-to-critical line distance (PCLD), the plate-to-volar rim distance (PVRD), and the time of plate removal were significantly associated with FPL attrition or rupture. Multivariate logistic regression analysis demonstrated that decreased volar tilt, Soong grade 2, PCLD of >2 mm, PVRD of <3 mm, and plate removal at ≥1 year were the risk factors significantly associated with FPL attrition or rupture. CONCLUSIONS: Reduced volar tilt, Soong grade 2, PCLD of >2 mm, and PVRD of <3 mm appear to be risk factors that are significantly associated with FPL attrition or rupture. The findings of this study also suggest that the risk of tendon rupture is lower if a Soong grade 2 plate is removed, the PCLD is >2 mm, the PVRD is <3 mm, or reduced volar tilt is achieved earlier (at <1 year). SAGE Publications 2021-08-08 /pmc/articles/PMC8358517/ /pubmed/34369195 http://dx.doi.org/10.1177/03000605211031438 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by-nc/4.0/Creative Commons Non Commercial CC BY-NC: This article is distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 License (https://creativecommons.org/licenses/by-nc/4.0/) which permits non-commercial use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access pages (https://us.sagepub.com/en-us/nam/open-access-at-sage). |
spellingShingle | Retrospective Clinical Research Report Lv, Yang-Xun Chen, Mang-Mang Su, Chen-Xian Ye, Hao-Nan Yang, Jie Li, Jing Analysis of risk factors associated with flexor pollicis longus injury after volar plating of distal radius fractures |
title | Analysis of risk factors associated with flexor pollicis longus injury after volar plating of distal radius fractures |
title_full | Analysis of risk factors associated with flexor pollicis longus injury after volar plating of distal radius fractures |
title_fullStr | Analysis of risk factors associated with flexor pollicis longus injury after volar plating of distal radius fractures |
title_full_unstemmed | Analysis of risk factors associated with flexor pollicis longus injury after volar plating of distal radius fractures |
title_short | Analysis of risk factors associated with flexor pollicis longus injury after volar plating of distal radius fractures |
title_sort | analysis of risk factors associated with flexor pollicis longus injury after volar plating of distal radius fractures |
topic | Retrospective Clinical Research Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8358517/ https://www.ncbi.nlm.nih.gov/pubmed/34369195 http://dx.doi.org/10.1177/03000605211031438 |
work_keys_str_mv | AT lvyangxun analysisofriskfactorsassociatedwithflexorpollicislongusinjuryaftervolarplatingofdistalradiusfractures AT chenmangmang analysisofriskfactorsassociatedwithflexorpollicislongusinjuryaftervolarplatingofdistalradiusfractures AT suchenxian analysisofriskfactorsassociatedwithflexorpollicislongusinjuryaftervolarplatingofdistalradiusfractures AT yehaonan analysisofriskfactorsassociatedwithflexorpollicislongusinjuryaftervolarplatingofdistalradiusfractures AT yangjie analysisofriskfactorsassociatedwithflexorpollicislongusinjuryaftervolarplatingofdistalradiusfractures AT lijing analysisofriskfactorsassociatedwithflexorpollicislongusinjuryaftervolarplatingofdistalradiusfractures |