Analysis of risk factors associated with flexor pollicis longus injury after volar plating of distal radius fractures

OBJECTIVE: This study was performed to analyze the risk factors associated with flexor pollicis longus (FPL) attrition or rupture after volar plating of distal radius fractures. METHODS: Three hundred thirty-eight patients with distal radius fractures were included in this retrospective study. Univa...

Descripción completa

Detalles Bibliográficos
Autores principales: Lv, Yang-Xun, Chen, Mang-Mang, Su, Chen-Xian, Ye, Hao-Nan, Yang, Jie, Li, Jing
Formato: Online Artículo Texto
Lenguaje:English
Publicado: SAGE Publications 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8358517/
https://www.ncbi.nlm.nih.gov/pubmed/34369195
http://dx.doi.org/10.1177/03000605211031438
_version_ 1783737357731627008
author Lv, Yang-Xun
Chen, Mang-Mang
Su, Chen-Xian
Ye, Hao-Nan
Yang, Jie
Li, Jing
author_facet Lv, Yang-Xun
Chen, Mang-Mang
Su, Chen-Xian
Ye, Hao-Nan
Yang, Jie
Li, Jing
author_sort Lv, Yang-Xun
collection PubMed
description OBJECTIVE: This study was performed to analyze the risk factors associated with flexor pollicis longus (FPL) attrition or rupture after volar plating of distal radius fractures. METHODS: Three hundred thirty-eight patients with distal radius fractures were included in this retrospective study. Univariate analysis and multivariate logistic regression analysis were performed to predict risk factors. RESULTS: Univariate analysis showed that sex, volar tilt, the Soong grade, the plate-to-critical line distance (PCLD), the plate-to-volar rim distance (PVRD), and the time of plate removal were significantly associated with FPL attrition or rupture. Multivariate logistic regression analysis demonstrated that decreased volar tilt, Soong grade 2, PCLD of >2 mm, PVRD of <3 mm, and plate removal at ≥1 year were the risk factors significantly associated with FPL attrition or rupture. CONCLUSIONS: Reduced volar tilt, Soong grade 2, PCLD of >2 mm, and PVRD of <3 mm appear to be risk factors that are significantly associated with FPL attrition or rupture. The findings of this study also suggest that the risk of tendon rupture is lower if a Soong grade 2 plate is removed, the PCLD is >2 mm, the PVRD is <3 mm, or reduced volar tilt is achieved earlier (at <1 year).
format Online
Article
Text
id pubmed-8358517
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher SAGE Publications
record_format MEDLINE/PubMed
spelling pubmed-83585172021-08-13 Analysis of risk factors associated with flexor pollicis longus injury after volar plating of distal radius fractures Lv, Yang-Xun Chen, Mang-Mang Su, Chen-Xian Ye, Hao-Nan Yang, Jie Li, Jing J Int Med Res Retrospective Clinical Research Report OBJECTIVE: This study was performed to analyze the risk factors associated with flexor pollicis longus (FPL) attrition or rupture after volar plating of distal radius fractures. METHODS: Three hundred thirty-eight patients with distal radius fractures were included in this retrospective study. Univariate analysis and multivariate logistic regression analysis were performed to predict risk factors. RESULTS: Univariate analysis showed that sex, volar tilt, the Soong grade, the plate-to-critical line distance (PCLD), the plate-to-volar rim distance (PVRD), and the time of plate removal were significantly associated with FPL attrition or rupture. Multivariate logistic regression analysis demonstrated that decreased volar tilt, Soong grade 2, PCLD of >2 mm, PVRD of <3 mm, and plate removal at ≥1 year were the risk factors significantly associated with FPL attrition or rupture. CONCLUSIONS: Reduced volar tilt, Soong grade 2, PCLD of >2 mm, and PVRD of <3 mm appear to be risk factors that are significantly associated with FPL attrition or rupture. The findings of this study also suggest that the risk of tendon rupture is lower if a Soong grade 2 plate is removed, the PCLD is >2 mm, the PVRD is <3 mm, or reduced volar tilt is achieved earlier (at <1 year). SAGE Publications 2021-08-08 /pmc/articles/PMC8358517/ /pubmed/34369195 http://dx.doi.org/10.1177/03000605211031438 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by-nc/4.0/Creative Commons Non Commercial CC BY-NC: This article is distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 License (https://creativecommons.org/licenses/by-nc/4.0/) which permits non-commercial use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access pages (https://us.sagepub.com/en-us/nam/open-access-at-sage).
spellingShingle Retrospective Clinical Research Report
Lv, Yang-Xun
Chen, Mang-Mang
Su, Chen-Xian
Ye, Hao-Nan
Yang, Jie
Li, Jing
Analysis of risk factors associated with flexor pollicis longus injury after volar plating of distal radius fractures
title Analysis of risk factors associated with flexor pollicis longus injury after volar plating of distal radius fractures
title_full Analysis of risk factors associated with flexor pollicis longus injury after volar plating of distal radius fractures
title_fullStr Analysis of risk factors associated with flexor pollicis longus injury after volar plating of distal radius fractures
title_full_unstemmed Analysis of risk factors associated with flexor pollicis longus injury after volar plating of distal radius fractures
title_short Analysis of risk factors associated with flexor pollicis longus injury after volar plating of distal radius fractures
title_sort analysis of risk factors associated with flexor pollicis longus injury after volar plating of distal radius fractures
topic Retrospective Clinical Research Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8358517/
https://www.ncbi.nlm.nih.gov/pubmed/34369195
http://dx.doi.org/10.1177/03000605211031438
work_keys_str_mv AT lvyangxun analysisofriskfactorsassociatedwithflexorpollicislongusinjuryaftervolarplatingofdistalradiusfractures
AT chenmangmang analysisofriskfactorsassociatedwithflexorpollicislongusinjuryaftervolarplatingofdistalradiusfractures
AT suchenxian analysisofriskfactorsassociatedwithflexorpollicislongusinjuryaftervolarplatingofdistalradiusfractures
AT yehaonan analysisofriskfactorsassociatedwithflexorpollicislongusinjuryaftervolarplatingofdistalradiusfractures
AT yangjie analysisofriskfactorsassociatedwithflexorpollicislongusinjuryaftervolarplatingofdistalradiusfractures
AT lijing analysisofriskfactorsassociatedwithflexorpollicislongusinjuryaftervolarplatingofdistalradiusfractures