Intraoperative Optical Coherence Tomography-Guided Bleb-sparing Epithelial Exchange: A Modified Approach

With the advent of newer technologies, real-time anterior segment optical coherence tomography (OCT) integrated with the operating microscope has become possible. We are proposing the technique of bleb revision with greater precision under direct visualization of bleb anatomy and extent of tissue de...

Descripción completa

Detalles Bibliográficos
Autores principales: Angmo, Dewang, Shakrawal, Jyoti, Sihota, Ramanjit
Formato: Online Artículo Texto
Lenguaje:English
Publicado: PUBLISHED BY KNOWLEDGE E 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8358750/
https://www.ncbi.nlm.nih.gov/pubmed/34394880
http://dx.doi.org/10.18502/jovr.v16i3.9447
_version_ 1783737406828052480
author Angmo, Dewang
Shakrawal, Jyoti
Sihota, Ramanjit
author_facet Angmo, Dewang
Shakrawal, Jyoti
Sihota, Ramanjit
author_sort Angmo, Dewang
collection PubMed
description With the advent of newer technologies, real-time anterior segment optical coherence tomography (OCT) integrated with the operating microscope has become possible. We are proposing the technique of bleb revision with greater precision under direct visualization of bleb anatomy and extent of tissue depth allowing better localization and easy maneuvering with lesser complications. In this surgical technique, bleb revision was performed using intraoperative real-time OCT incorporated in OPMI LUMERA 700 microscope. Live surgical and OCT view were seen on a common screen together. A moderately elevated, diffuse functional bleb was noted after three months of bleb revision in both cases with controlled intraocular pressure. Intraoperative OCT-guided bleb-sparing epithelial exchange is an adjunctive technique for bleb repair surgery with an increased precision of surgery which can reduce complications, minimize surgical time and maximize surgical outcome.
format Online
Article
Text
id pubmed-8358750
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher PUBLISHED BY KNOWLEDGE E
record_format MEDLINE/PubMed
spelling pubmed-83587502021-08-13 Intraoperative Optical Coherence Tomography-Guided Bleb-sparing Epithelial Exchange: A Modified Approach Angmo, Dewang Shakrawal, Jyoti Sihota, Ramanjit J Ophthalmic Vis Res Surgical Technique With the advent of newer technologies, real-time anterior segment optical coherence tomography (OCT) integrated with the operating microscope has become possible. We are proposing the technique of bleb revision with greater precision under direct visualization of bleb anatomy and extent of tissue depth allowing better localization and easy maneuvering with lesser complications. In this surgical technique, bleb revision was performed using intraoperative real-time OCT incorporated in OPMI LUMERA 700 microscope. Live surgical and OCT view were seen on a common screen together. A moderately elevated, diffuse functional bleb was noted after three months of bleb revision in both cases with controlled intraocular pressure. Intraoperative OCT-guided bleb-sparing epithelial exchange is an adjunctive technique for bleb repair surgery with an increased precision of surgery which can reduce complications, minimize surgical time and maximize surgical outcome. PUBLISHED BY KNOWLEDGE E 2021-07-29 /pmc/articles/PMC8358750/ /pubmed/34394880 http://dx.doi.org/10.18502/jovr.v16i3.9447 Text en Copyright © 2021 Angmo et al. https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Surgical Technique
Angmo, Dewang
Shakrawal, Jyoti
Sihota, Ramanjit
Intraoperative Optical Coherence Tomography-Guided Bleb-sparing Epithelial Exchange: A Modified Approach
title Intraoperative Optical Coherence Tomography-Guided Bleb-sparing Epithelial Exchange: A Modified Approach
title_full Intraoperative Optical Coherence Tomography-Guided Bleb-sparing Epithelial Exchange: A Modified Approach
title_fullStr Intraoperative Optical Coherence Tomography-Guided Bleb-sparing Epithelial Exchange: A Modified Approach
title_full_unstemmed Intraoperative Optical Coherence Tomography-Guided Bleb-sparing Epithelial Exchange: A Modified Approach
title_short Intraoperative Optical Coherence Tomography-Guided Bleb-sparing Epithelial Exchange: A Modified Approach
title_sort intraoperative optical coherence tomography-guided bleb-sparing epithelial exchange: a modified approach
topic Surgical Technique
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8358750/
https://www.ncbi.nlm.nih.gov/pubmed/34394880
http://dx.doi.org/10.18502/jovr.v16i3.9447
work_keys_str_mv AT angmodewang intraoperativeopticalcoherencetomographyguidedblebsparingepithelialexchangeamodifiedapproach
AT shakrawaljyoti intraoperativeopticalcoherencetomographyguidedblebsparingepithelialexchangeamodifiedapproach
AT sihotaramanjit intraoperativeopticalcoherencetomographyguidedblebsparingepithelialexchangeamodifiedapproach