Cargando…
Intraoperative Optical Coherence Tomography-Guided Bleb-sparing Epithelial Exchange: A Modified Approach
With the advent of newer technologies, real-time anterior segment optical coherence tomography (OCT) integrated with the operating microscope has become possible. We are proposing the technique of bleb revision with greater precision under direct visualization of bleb anatomy and extent of tissue de...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
PUBLISHED BY KNOWLEDGE E
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8358750/ https://www.ncbi.nlm.nih.gov/pubmed/34394880 http://dx.doi.org/10.18502/jovr.v16i3.9447 |
_version_ | 1783737406828052480 |
---|---|
author | Angmo, Dewang Shakrawal, Jyoti Sihota, Ramanjit |
author_facet | Angmo, Dewang Shakrawal, Jyoti Sihota, Ramanjit |
author_sort | Angmo, Dewang |
collection | PubMed |
description | With the advent of newer technologies, real-time anterior segment optical coherence tomography (OCT) integrated with the operating microscope has become possible. We are proposing the technique of bleb revision with greater precision under direct visualization of bleb anatomy and extent of tissue depth allowing better localization and easy maneuvering with lesser complications. In this surgical technique, bleb revision was performed using intraoperative real-time OCT incorporated in OPMI LUMERA 700 microscope. Live surgical and OCT view were seen on a common screen together. A moderately elevated, diffuse functional bleb was noted after three months of bleb revision in both cases with controlled intraocular pressure. Intraoperative OCT-guided bleb-sparing epithelial exchange is an adjunctive technique for bleb repair surgery with an increased precision of surgery which can reduce complications, minimize surgical time and maximize surgical outcome. |
format | Online Article Text |
id | pubmed-8358750 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | PUBLISHED BY KNOWLEDGE E |
record_format | MEDLINE/PubMed |
spelling | pubmed-83587502021-08-13 Intraoperative Optical Coherence Tomography-Guided Bleb-sparing Epithelial Exchange: A Modified Approach Angmo, Dewang Shakrawal, Jyoti Sihota, Ramanjit J Ophthalmic Vis Res Surgical Technique With the advent of newer technologies, real-time anterior segment optical coherence tomography (OCT) integrated with the operating microscope has become possible. We are proposing the technique of bleb revision with greater precision under direct visualization of bleb anatomy and extent of tissue depth allowing better localization and easy maneuvering with lesser complications. In this surgical technique, bleb revision was performed using intraoperative real-time OCT incorporated in OPMI LUMERA 700 microscope. Live surgical and OCT view were seen on a common screen together. A moderately elevated, diffuse functional bleb was noted after three months of bleb revision in both cases with controlled intraocular pressure. Intraoperative OCT-guided bleb-sparing epithelial exchange is an adjunctive technique for bleb repair surgery with an increased precision of surgery which can reduce complications, minimize surgical time and maximize surgical outcome. PUBLISHED BY KNOWLEDGE E 2021-07-29 /pmc/articles/PMC8358750/ /pubmed/34394880 http://dx.doi.org/10.18502/jovr.v16i3.9447 Text en Copyright © 2021 Angmo et al. https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Surgical Technique Angmo, Dewang Shakrawal, Jyoti Sihota, Ramanjit Intraoperative Optical Coherence Tomography-Guided Bleb-sparing Epithelial Exchange: A Modified Approach |
title | Intraoperative Optical Coherence Tomography-Guided Bleb-sparing Epithelial Exchange: A Modified Approach |
title_full | Intraoperative Optical Coherence Tomography-Guided Bleb-sparing Epithelial Exchange: A Modified Approach |
title_fullStr | Intraoperative Optical Coherence Tomography-Guided Bleb-sparing Epithelial Exchange: A Modified Approach |
title_full_unstemmed | Intraoperative Optical Coherence Tomography-Guided Bleb-sparing Epithelial Exchange: A Modified Approach |
title_short | Intraoperative Optical Coherence Tomography-Guided Bleb-sparing Epithelial Exchange: A Modified Approach |
title_sort | intraoperative optical coherence tomography-guided bleb-sparing epithelial exchange: a modified approach |
topic | Surgical Technique |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8358750/ https://www.ncbi.nlm.nih.gov/pubmed/34394880 http://dx.doi.org/10.18502/jovr.v16i3.9447 |
work_keys_str_mv | AT angmodewang intraoperativeopticalcoherencetomographyguidedblebsparingepithelialexchangeamodifiedapproach AT shakrawaljyoti intraoperativeopticalcoherencetomographyguidedblebsparingepithelialexchangeamodifiedapproach AT sihotaramanjit intraoperativeopticalcoherencetomographyguidedblebsparingepithelialexchangeamodifiedapproach |