Ideal Illumination for Smartphone-based Trabeculectomy Bleb Photography
PURPOSE: Ophthalmology has seen numerous novel uses for smartphones over the years including fundus photography, telemedicine, and operative videography. However, anterior segment photography for assessing and documenting trabeculectomy bleb morphology using a smartphone has not been explored in det...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
PUBLISHED BY KNOWLEDGE E
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8358752/ https://www.ncbi.nlm.nih.gov/pubmed/34394864 http://dx.doi.org/10.18502/jovr.v16i3.9432 |
_version_ | 1783737407274745856 |
---|---|
author | Kalra, Gagan Ichhpujani, Parul Thakur, Sahil Sharma, Urvashi |
author_facet | Kalra, Gagan Ichhpujani, Parul Thakur, Sahil Sharma, Urvashi |
author_sort | Kalra, Gagan |
collection | PubMed |
description | PURPOSE: Ophthalmology has seen numerous novel uses for smartphones over the years including fundus photography, telemedicine, and operative videography. However, anterior segment photography for assessing and documenting trabeculectomy bleb morphology using a smartphone has not been explored in detail. With the current study, we aim to characterize ideal illumination for the anterior segment smartphone photography in trabeculectomy patients. METHODS: Thirty status post-trabeculectomy patients were enrolled in this study. Native camera application and FiLMiC pro camera application were used on iPhone X to compare bleb images using yellow and white pen-torches as illumination source. Measured bleb area was compared using ImageJ software from the two apps in different illumination settings by charting boxplots and using one-way ANOVA test using R software to establish consistency. Bland-Altman interoperability for repeatability of bleb-area measurements was analyzed by plotting Bland-Altman plots. Signal-to-noise ratio was calculated using ImageJ for native camera images using slit-lamp camera images as reference. Subjective rating of these images was then performed by two experienced ophthalmologists and kappa coefficient was calculated for inter-operator repeatability. Statistical analysis was performed. RESULTS: The measured bleb area from images taken from both apps showed no significant difference, thereby establishing consistency, and Bland-Altman analysis indicated good repeatability and reproducibility. It was noted that SNR was lower for images shot in close illumination as compared to the ones shot in intermediate and distant illumination. Cohen's kappa coefficient was 0.7 for images with distant illumination using white light and 0.65 for images clicked with illumination at an intermediate distance using yellow light, suggesting substantial agreement between the observers. CONCLUSION: Smartphone photography is a reliable tool for morphological assessment trabeculectomy blebs. Optimal illumination helps achieve results free from digital noise and better delineation of specific morphological features. Intermediate illumination and distant illumination provides much better results in terms of high SNR while avoiding overexposure and clipping of highlight information in the images. |
format | Online Article Text |
id | pubmed-8358752 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | PUBLISHED BY KNOWLEDGE E |
record_format | MEDLINE/PubMed |
spelling | pubmed-83587522021-08-13 Ideal Illumination for Smartphone-based Trabeculectomy Bleb Photography Kalra, Gagan Ichhpujani, Parul Thakur, Sahil Sharma, Urvashi J Ophthalmic Vis Res Original Article PURPOSE: Ophthalmology has seen numerous novel uses for smartphones over the years including fundus photography, telemedicine, and operative videography. However, anterior segment photography for assessing and documenting trabeculectomy bleb morphology using a smartphone has not been explored in detail. With the current study, we aim to characterize ideal illumination for the anterior segment smartphone photography in trabeculectomy patients. METHODS: Thirty status post-trabeculectomy patients were enrolled in this study. Native camera application and FiLMiC pro camera application were used on iPhone X to compare bleb images using yellow and white pen-torches as illumination source. Measured bleb area was compared using ImageJ software from the two apps in different illumination settings by charting boxplots and using one-way ANOVA test using R software to establish consistency. Bland-Altman interoperability for repeatability of bleb-area measurements was analyzed by plotting Bland-Altman plots. Signal-to-noise ratio was calculated using ImageJ for native camera images using slit-lamp camera images as reference. Subjective rating of these images was then performed by two experienced ophthalmologists and kappa coefficient was calculated for inter-operator repeatability. Statistical analysis was performed. RESULTS: The measured bleb area from images taken from both apps showed no significant difference, thereby establishing consistency, and Bland-Altman analysis indicated good repeatability and reproducibility. It was noted that SNR was lower for images shot in close illumination as compared to the ones shot in intermediate and distant illumination. Cohen's kappa coefficient was 0.7 for images with distant illumination using white light and 0.65 for images clicked with illumination at an intermediate distance using yellow light, suggesting substantial agreement between the observers. CONCLUSION: Smartphone photography is a reliable tool for morphological assessment trabeculectomy blebs. Optimal illumination helps achieve results free from digital noise and better delineation of specific morphological features. Intermediate illumination and distant illumination provides much better results in terms of high SNR while avoiding overexposure and clipping of highlight information in the images. PUBLISHED BY KNOWLEDGE E 2021-07-29 /pmc/articles/PMC8358752/ /pubmed/34394864 http://dx.doi.org/10.18502/jovr.v16i3.9432 Text en Copyright © 2021 Kalra et al. https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Kalra, Gagan Ichhpujani, Parul Thakur, Sahil Sharma, Urvashi Ideal Illumination for Smartphone-based Trabeculectomy Bleb Photography |
title | Ideal Illumination for Smartphone-based Trabeculectomy Bleb Photography |
title_full | Ideal Illumination for Smartphone-based Trabeculectomy Bleb Photography |
title_fullStr | Ideal Illumination for Smartphone-based Trabeculectomy Bleb Photography |
title_full_unstemmed | Ideal Illumination for Smartphone-based Trabeculectomy Bleb Photography |
title_short | Ideal Illumination for Smartphone-based Trabeculectomy Bleb Photography |
title_sort | ideal illumination for smartphone-based trabeculectomy bleb photography |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8358752/ https://www.ncbi.nlm.nih.gov/pubmed/34394864 http://dx.doi.org/10.18502/jovr.v16i3.9432 |
work_keys_str_mv | AT kalragagan idealilluminationforsmartphonebasedtrabeculectomyblebphotography AT ichhpujaniparul idealilluminationforsmartphonebasedtrabeculectomyblebphotography AT thakursahil idealilluminationforsmartphonebasedtrabeculectomyblebphotography AT sharmaurvashi idealilluminationforsmartphonebasedtrabeculectomyblebphotography |