Variables that Influence Platelet Function Analyzer-100™ Closure Times in Healthy Algerian Adults

CONTEXT: The Platelet Function Analyzer (PFA-100™) assesses primary hemostasis in vitro under high shear stress to simulate the conditions to which platelets are exposed at the site of an injured blood vessel wall. AIMS: We investigated preanalytical variables in healthy Algerian adults, and we also...

Descripción completa

Detalles Bibliográficos
Autores principales: Belkacemi, Malika, Merad, Yassine
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer - Medknow 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8360221/
https://www.ncbi.nlm.nih.gov/pubmed/34458117
http://dx.doi.org/10.4103/ijabmr.IJABMR_532_20
_version_ 1783737703839301632
author Belkacemi, Malika
Merad, Yassine
author_facet Belkacemi, Malika
Merad, Yassine
author_sort Belkacemi, Malika
collection PubMed
description CONTEXT: The Platelet Function Analyzer (PFA-100™) assesses primary hemostasis in vitro under high shear stress to simulate the conditions to which platelets are exposed at the site of an injured blood vessel wall. AIMS: We investigated preanalytical variables in healthy Algerian adults, and we also assess the performance of the test. SUBJECTS AND METHODS: Closure time (CT) was measured in 302 well-characterized healthy Algerian adults with the collagen/epinephrine (CEPI) and the collagen/adenosine diphosphate (CADP) cartridges. RESULTS: Age and sex did not affect CT values. Blood group O was associated significantly with longer CEPI CT and CADP CT than non-O groups (P ≤ 0.0001 for both). CTs were shorter in samples collected in the morning vs the afternoon (P < 0.0001 for both). We found a strong positive correlation between CT CEPI and CT CADP with r = 0.72 and P < 0.001 and an inverse mean correlation between von Willebrand factor level and CT with r = −0.56, r = −0.45 for CT CEPI and CT CADP, respectively P < 0.001. Duplicate analysis of PFA-100™ CT revealed a mean difference of 3.6% ±19.1% for the CEPI cartridge and 1.5% ±10% for the CADP cartridge. The mean coefficient of variation was 7.4% for the CADP CT and 7.6% for the CEPI CT. No marked difference between test positions. CONCLUSIONS: The PFA-100™ showed good reproducibility. The variables influencing the test in healthy Algerian adults are similar to Western and Asian populations. Standardization of preanalytical and analytical conditions is essential for obtaining reliable PFA-100™ results.
format Online
Article
Text
id pubmed-8360221
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Wolters Kluwer - Medknow
record_format MEDLINE/PubMed
spelling pubmed-83602212021-08-27 Variables that Influence Platelet Function Analyzer-100™ Closure Times in Healthy Algerian Adults Belkacemi, Malika Merad, Yassine Int J Appl Basic Med Res Original Article CONTEXT: The Platelet Function Analyzer (PFA-100™) assesses primary hemostasis in vitro under high shear stress to simulate the conditions to which platelets are exposed at the site of an injured blood vessel wall. AIMS: We investigated preanalytical variables in healthy Algerian adults, and we also assess the performance of the test. SUBJECTS AND METHODS: Closure time (CT) was measured in 302 well-characterized healthy Algerian adults with the collagen/epinephrine (CEPI) and the collagen/adenosine diphosphate (CADP) cartridges. RESULTS: Age and sex did not affect CT values. Blood group O was associated significantly with longer CEPI CT and CADP CT than non-O groups (P ≤ 0.0001 for both). CTs were shorter in samples collected in the morning vs the afternoon (P < 0.0001 for both). We found a strong positive correlation between CT CEPI and CT CADP with r = 0.72 and P < 0.001 and an inverse mean correlation between von Willebrand factor level and CT with r = −0.56, r = −0.45 for CT CEPI and CT CADP, respectively P < 0.001. Duplicate analysis of PFA-100™ CT revealed a mean difference of 3.6% ±19.1% for the CEPI cartridge and 1.5% ±10% for the CADP cartridge. The mean coefficient of variation was 7.4% for the CADP CT and 7.6% for the CEPI CT. No marked difference between test positions. CONCLUSIONS: The PFA-100™ showed good reproducibility. The variables influencing the test in healthy Algerian adults are similar to Western and Asian populations. Standardization of preanalytical and analytical conditions is essential for obtaining reliable PFA-100™ results. Wolters Kluwer - Medknow 2021 2021-07-19 /pmc/articles/PMC8360221/ /pubmed/34458117 http://dx.doi.org/10.4103/ijabmr.IJABMR_532_20 Text en Copyright: © 2021 International Journal of Applied and Basic Medical Research https://creativecommons.org/licenses/by-nc-sa/4.0/This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
spellingShingle Original Article
Belkacemi, Malika
Merad, Yassine
Variables that Influence Platelet Function Analyzer-100™ Closure Times in Healthy Algerian Adults
title Variables that Influence Platelet Function Analyzer-100™ Closure Times in Healthy Algerian Adults
title_full Variables that Influence Platelet Function Analyzer-100™ Closure Times in Healthy Algerian Adults
title_fullStr Variables that Influence Platelet Function Analyzer-100™ Closure Times in Healthy Algerian Adults
title_full_unstemmed Variables that Influence Platelet Function Analyzer-100™ Closure Times in Healthy Algerian Adults
title_short Variables that Influence Platelet Function Analyzer-100™ Closure Times in Healthy Algerian Adults
title_sort variables that influence platelet function analyzer-100™ closure times in healthy algerian adults
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8360221/
https://www.ncbi.nlm.nih.gov/pubmed/34458117
http://dx.doi.org/10.4103/ijabmr.IJABMR_532_20
work_keys_str_mv AT belkacemimalika variablesthatinfluenceplateletfunctionanalyzer100closuretimesinhealthyalgerianadults
AT meradyassine variablesthatinfluenceplateletfunctionanalyzer100closuretimesinhealthyalgerianadults