Risk Management of Clinical Reference Dosimetry of a Large Hospital Network Using Statistical Process Control
Managing TG-51 reference dosimetry in a large hospital network can be a challenging task. The objectives of this study are to investigate the effectiveness of using Statistical Process Control (SPC) to manage TG-51 workflow in such a network. All the sites in the network performed the annual referen...
Autores principales: | Lim, Seng-Boh, LoSasso, Thomas, Chan, Maria, Cervino, Laura, Lovelock, Dale Michael |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8360384/ https://www.ncbi.nlm.nih.gov/pubmed/34395105 http://dx.doi.org/10.4236/ijmpcero.2021.103011 |
Ejemplares similares
-
An investigation of using log‐file analysis for automated patient‐specific quality assurance in MRgRT
por: Lim, Seng Boh, et al.
Publicado: (2021) -
Can the Risk of Dysphagia in Head and Neck Radiation Therapy Be Predicted by an Automated Transit Fluence Monitoring Process During Treatment? A First Comparative Study of Patient Reported Quality of Life and the Fluence-Based Decision Support Metric
por: Lim, Seng Boh, et al.
Publicado: (2021) -
A novel quality assurance procedure for trajectory log validation using phantom‐less real‐time latency corrected EPID images
por: Lim, Seng Boh, et al.
Publicado: (2021) -
Comparative study of SRS end‐to‐end QA processes of a diode array device and an anthropomorphic phantom loaded with GafChromic XD film
por: Lim, Seng Boh, et al.
Publicado: (2022) -
Dosimetric evaluation of irradiation geometry and potential air gaps in an acrylic miniphantom used for external audit of absolute dose calibration for a hybrid 1.5 T MR‐linac system
por: Tyagi, Neelam, et al.
Publicado: (2021)