BACKGROUND: Neonates and small infants with congenital cardiac disease undergoing cardiac surgery represent major challenges facing paediatric anaesthesia and perioperative medicine. Aims. We here aimed to investigate the success rates in performing ultrasound (US) guided central venous catheter ins...

Descripción completa

Detalles Bibliográficos
Autores principales: Schiefer, Judith, Lichtenegger, Paul, Zimpfer, Daniel, Hutschala, Doris, Kuessel, Lorenz, Felli, Alessia, Hornykewycz, Stephan, Faybik, Peter, Base, Eva
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8360777/
https://www.ncbi.nlm.nih.gov/pubmed/34389009
http://dx.doi.org/10.1186/s12887-021-02822-w
_version_ 1783737813289664512
author Schiefer, Judith
Lichtenegger, Paul
Zimpfer, Daniel
Hutschala, Doris
Kuessel, Lorenz
Felli, Alessia
Hornykewycz, Stephan
Faybik, Peter
Base, Eva
author_facet Schiefer, Judith
Lichtenegger, Paul
Zimpfer, Daniel
Hutschala, Doris
Kuessel, Lorenz
Felli, Alessia
Hornykewycz, Stephan
Faybik, Peter
Base, Eva
author_sort Schiefer, Judith
collection PubMed
description BACKGROUND: Neonates and small infants with congenital cardiac disease undergoing cardiac surgery represent major challenges facing paediatric anaesthesia and perioperative medicine. Aims. We here aimed to investigate the success rates in performing ultrasound (US) guided central venous catheter insertion (CVC) in neonates and small infants undergoing cardiac surgery, and to evaluate the practicability and feasibility of thereby using a novel wireless US transducer (WUST). METHODS: Thirty neonates and small infants with a maximum body weight of 10 kg and need for CVC before cardiac surgery were included in this observational trial and were subdivided into two groups according to their weight: < 5 kg and ≥ 5 kg. Cannulation success, failure rate, essential procedure related time periods, and complications were recorded and the clinical utility of the WUST was assessed by a 5-point Likert scale. RESULTS: In total, CVC-insertion was successful in 27 (90%) of the patients and the first attempt was successful in 24 (78%) of patients. Success rates of CVC were 80% < 5 kg and 100% ≥5 kg. Comparing the two groups we found a clear trend towards longer needle insertion time in patients weighing < 5 kg (33 [28–69] vs. 24 [15–37]s, P = .07), whereas, the total time for catheter insertion and the duration of the whole procedure were similar in both groups (199 [167–228] vs. 178 [138–234] and 720[538–818] vs. 660 [562–833]s. In total, we report 3 (10%) cases of local hematoma as procedure-related complications. Assessments of the WUST revealed very good survey results for all parameters of practicability and handling (all ratings between 4.5 and 5.0). CONCLUSION: Although difficulties in CVC-placement seem to relate to vessel size and patient’s weight, US guided CVC-insertion represents a valuable, fast, and safe intervention in neonates and small children undergoing cardiac surgery. Using the WUST is feasible for this clinical application and may aid in efforts aiming to optimize perioperative care. TRIAL REGISTRATION: Wireless US-guided CVC placement in infants; Clinicaltrials.gov: NCT04597021; Date of Registration: 21October, 2020; retrospectively registered.
format Online
Article
Text
id pubmed-8360777
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-83607772021-08-13 Performing central venous catheters in neonates and small infants undergoing cardiac surgery using a wireless transducer for ultrasound guidance: a prospective, observational pilot study Schiefer, Judith Lichtenegger, Paul Zimpfer, Daniel Hutschala, Doris Kuessel, Lorenz Felli, Alessia Hornykewycz, Stephan Faybik, Peter Base, Eva BMC Pediatr Research Article BACKGROUND: Neonates and small infants with congenital cardiac disease undergoing cardiac surgery represent major challenges facing paediatric anaesthesia and perioperative medicine. Aims. We here aimed to investigate the success rates in performing ultrasound (US) guided central venous catheter insertion (CVC) in neonates and small infants undergoing cardiac surgery, and to evaluate the practicability and feasibility of thereby using a novel wireless US transducer (WUST). METHODS: Thirty neonates and small infants with a maximum body weight of 10 kg and need for CVC before cardiac surgery were included in this observational trial and were subdivided into two groups according to their weight: < 5 kg and ≥ 5 kg. Cannulation success, failure rate, essential procedure related time periods, and complications were recorded and the clinical utility of the WUST was assessed by a 5-point Likert scale. RESULTS: In total, CVC-insertion was successful in 27 (90%) of the patients and the first attempt was successful in 24 (78%) of patients. Success rates of CVC were 80% < 5 kg and 100% ≥5 kg. Comparing the two groups we found a clear trend towards longer needle insertion time in patients weighing < 5 kg (33 [28–69] vs. 24 [15–37]s, P = .07), whereas, the total time for catheter insertion and the duration of the whole procedure were similar in both groups (199 [167–228] vs. 178 [138–234] and 720[538–818] vs. 660 [562–833]s. In total, we report 3 (10%) cases of local hematoma as procedure-related complications. Assessments of the WUST revealed very good survey results for all parameters of practicability and handling (all ratings between 4.5 and 5.0). CONCLUSION: Although difficulties in CVC-placement seem to relate to vessel size and patient’s weight, US guided CVC-insertion represents a valuable, fast, and safe intervention in neonates and small children undergoing cardiac surgery. Using the WUST is feasible for this clinical application and may aid in efforts aiming to optimize perioperative care. TRIAL REGISTRATION: Wireless US-guided CVC placement in infants; Clinicaltrials.gov: NCT04597021; Date of Registration: 21October, 2020; retrospectively registered. BioMed Central 2021-08-13 /pmc/articles/PMC8360777/ /pubmed/34389009 http://dx.doi.org/10.1186/s12887-021-02822-w Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research Article
Schiefer, Judith
Lichtenegger, Paul
Zimpfer, Daniel
Hutschala, Doris
Kuessel, Lorenz
Felli, Alessia
Hornykewycz, Stephan
Faybik, Peter
Base, Eva
Performing central venous catheters in neonates and small infants undergoing cardiac surgery using a wireless transducer for ultrasound guidance: a prospective, observational pilot study
title Performing central venous catheters in neonates and small infants undergoing cardiac surgery using a wireless transducer for ultrasound guidance: a prospective, observational pilot study
title_full Performing central venous catheters in neonates and small infants undergoing cardiac surgery using a wireless transducer for ultrasound guidance: a prospective, observational pilot study
title_fullStr Performing central venous catheters in neonates and small infants undergoing cardiac surgery using a wireless transducer for ultrasound guidance: a prospective, observational pilot study
title_full_unstemmed Performing central venous catheters in neonates and small infants undergoing cardiac surgery using a wireless transducer for ultrasound guidance: a prospective, observational pilot study
title_short Performing central venous catheters in neonates and small infants undergoing cardiac surgery using a wireless transducer for ultrasound guidance: a prospective, observational pilot study
title_sort performing central venous catheters in neonates and small infants undergoing cardiac surgery using a wireless transducer for ultrasound guidance: a prospective, observational pilot study
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8360777/
https://www.ncbi.nlm.nih.gov/pubmed/34389009
http://dx.doi.org/10.1186/s12887-021-02822-w
work_keys_str_mv AT schieferjudith performingcentralvenouscathetersinneonatesandsmallinfantsundergoingcardiacsurgeryusingawirelesstransducerforultrasoundguidanceaprospectiveobservationalpilotstudy
AT lichteneggerpaul performingcentralvenouscathetersinneonatesandsmallinfantsundergoingcardiacsurgeryusingawirelesstransducerforultrasoundguidanceaprospectiveobservationalpilotstudy
AT zimpferdaniel performingcentralvenouscathetersinneonatesandsmallinfantsundergoingcardiacsurgeryusingawirelesstransducerforultrasoundguidanceaprospectiveobservationalpilotstudy
AT hutschaladoris performingcentralvenouscathetersinneonatesandsmallinfantsundergoingcardiacsurgeryusingawirelesstransducerforultrasoundguidanceaprospectiveobservationalpilotstudy
AT kuessellorenz performingcentralvenouscathetersinneonatesandsmallinfantsundergoingcardiacsurgeryusingawirelesstransducerforultrasoundguidanceaprospectiveobservationalpilotstudy
AT fellialessia performingcentralvenouscathetersinneonatesandsmallinfantsundergoingcardiacsurgeryusingawirelesstransducerforultrasoundguidanceaprospectiveobservationalpilotstudy
AT hornykewyczstephan performingcentralvenouscathetersinneonatesandsmallinfantsundergoingcardiacsurgeryusingawirelesstransducerforultrasoundguidanceaprospectiveobservationalpilotstudy
AT faybikpeter performingcentralvenouscathetersinneonatesandsmallinfantsundergoingcardiacsurgeryusingawirelesstransducerforultrasoundguidanceaprospectiveobservationalpilotstudy
AT baseeva performingcentralvenouscathetersinneonatesandsmallinfantsundergoingcardiacsurgeryusingawirelesstransducerforultrasoundguidanceaprospectiveobservationalpilotstudy