Cargando…

Jumbo cup in hip joint renovation may cause the center of rotation to increase

BACKGROUND: Utilizing the large jumbo cup in revision total hip arthroplasty is an effective approach to cure many lacunar and segmental peripheral bone defects. However, with the use of the jumbo cup, the center of the hip joint may become elevated relative to the primary acetabulum, and the diamet...

Descripción completa

Detalles Bibliográficos
Autores principales: Peng, Ya-Wen, Shen, Jun-Min, Zhang, Yan-Chao, Sun, Jing-Yang, Du, Yin-Qiao, Zhou, Yong-Gang
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Baishideng Publishing Group Inc 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8362550/
https://www.ncbi.nlm.nih.gov/pubmed/34434996
http://dx.doi.org/10.12998/wjcc.v9.i22.6300
_version_ 1783738187573624832
author Peng, Ya-Wen
Shen, Jun-Min
Zhang, Yan-Chao
Sun, Jing-Yang
Du, Yin-Qiao
Zhou, Yong-Gang
author_facet Peng, Ya-Wen
Shen, Jun-Min
Zhang, Yan-Chao
Sun, Jing-Yang
Du, Yin-Qiao
Zhou, Yong-Gang
author_sort Peng, Ya-Wen
collection PubMed
description BACKGROUND: Utilizing the large jumbo cup in revision total hip arthroplasty is an effective approach to cure many lacunar and segmental peripheral bone defects. However, with the use of the jumbo cup, the center of the hip joint may become elevated relative to the primary acetabulum, and the diameter of the large cup is greater. AIM: To study the height and the significance of the elevation of the hip joint center. METHODS: Eighty-eight patients matched the criteria for this condition and were included in the study. The center height of the hip joint was measured relative to the opposite normal hip joint. The diameter of the jumbo cup was measured and checked according to operation notes, and the diameter of the jumbo cup was measured with a prosthesis label. Then, the horizontal and vertical centers of rotation were measured on the surgical side and opposite side. The average center height of the hip joint on the renovated side and the opposite side and the position of the hip cup relative to the teardrop were compared using a paired t-test. RESULTS: Radiometric analysis showed that the average hip joint center was elevated by 7.6 mm. The rotational center height delta of the renovated hip was 7.6 ± 5.6 mm, and there was an obvious difference between the two groups (P = 0.00). The difference in horizontal distance was 0.5 ± 5.1 mm (-11.5 -14.0 mm), and there was no obvious difference between the two groups (P = 0.38). According to the foreign standard, the rotational center height delta of the renovated hip was 7.5 ± 6.2 mm, and there was a significant difference between the two groups (P = 0.00). There was no obvious difference between the domestic and foreign standards (P > 0.05) between the two groups. CONCLUSION: The application of the jumbo cup elevates the rotational center of the hip joint, but it is feasible and effective to use the jumbo cup.
format Online
Article
Text
id pubmed-8362550
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Baishideng Publishing Group Inc
record_format MEDLINE/PubMed
spelling pubmed-83625502021-08-24 Jumbo cup in hip joint renovation may cause the center of rotation to increase Peng, Ya-Wen Shen, Jun-Min Zhang, Yan-Chao Sun, Jing-Yang Du, Yin-Qiao Zhou, Yong-Gang World J Clin Cases Retrospective Study BACKGROUND: Utilizing the large jumbo cup in revision total hip arthroplasty is an effective approach to cure many lacunar and segmental peripheral bone defects. However, with the use of the jumbo cup, the center of the hip joint may become elevated relative to the primary acetabulum, and the diameter of the large cup is greater. AIM: To study the height and the significance of the elevation of the hip joint center. METHODS: Eighty-eight patients matched the criteria for this condition and were included in the study. The center height of the hip joint was measured relative to the opposite normal hip joint. The diameter of the jumbo cup was measured and checked according to operation notes, and the diameter of the jumbo cup was measured with a prosthesis label. Then, the horizontal and vertical centers of rotation were measured on the surgical side and opposite side. The average center height of the hip joint on the renovated side and the opposite side and the position of the hip cup relative to the teardrop were compared using a paired t-test. RESULTS: Radiometric analysis showed that the average hip joint center was elevated by 7.6 mm. The rotational center height delta of the renovated hip was 7.6 ± 5.6 mm, and there was an obvious difference between the two groups (P = 0.00). The difference in horizontal distance was 0.5 ± 5.1 mm (-11.5 -14.0 mm), and there was no obvious difference between the two groups (P = 0.38). According to the foreign standard, the rotational center height delta of the renovated hip was 7.5 ± 6.2 mm, and there was a significant difference between the two groups (P = 0.00). There was no obvious difference between the domestic and foreign standards (P > 0.05) between the two groups. CONCLUSION: The application of the jumbo cup elevates the rotational center of the hip joint, but it is feasible and effective to use the jumbo cup. Baishideng Publishing Group Inc 2021-08-06 2021-08-06 /pmc/articles/PMC8362550/ /pubmed/34434996 http://dx.doi.org/10.12998/wjcc.v9.i22.6300 Text en ©The Author(s) 2021. Published by Baishideng Publishing Group Inc. All rights reserved. https://creativecommons.org/licenses/by-nc/4.0/This article is an open-access article that was selected by an in-house editor and fully peer-reviewed by external reviewers. It is distributed in accordance with the Creative Commons Attribution NonCommercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited and the use is non-commercial. See: http://creativecommons.org/Licenses/by-nc/4.0/
spellingShingle Retrospective Study
Peng, Ya-Wen
Shen, Jun-Min
Zhang, Yan-Chao
Sun, Jing-Yang
Du, Yin-Qiao
Zhou, Yong-Gang
Jumbo cup in hip joint renovation may cause the center of rotation to increase
title Jumbo cup in hip joint renovation may cause the center of rotation to increase
title_full Jumbo cup in hip joint renovation may cause the center of rotation to increase
title_fullStr Jumbo cup in hip joint renovation may cause the center of rotation to increase
title_full_unstemmed Jumbo cup in hip joint renovation may cause the center of rotation to increase
title_short Jumbo cup in hip joint renovation may cause the center of rotation to increase
title_sort jumbo cup in hip joint renovation may cause the center of rotation to increase
topic Retrospective Study
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8362550/
https://www.ncbi.nlm.nih.gov/pubmed/34434996
http://dx.doi.org/10.12998/wjcc.v9.i22.6300
work_keys_str_mv AT pengyawen jumbocupinhipjointrenovationmaycausethecenterofrotationtoincrease
AT shenjunmin jumbocupinhipjointrenovationmaycausethecenterofrotationtoincrease
AT zhangyanchao jumbocupinhipjointrenovationmaycausethecenterofrotationtoincrease
AT sunjingyang jumbocupinhipjointrenovationmaycausethecenterofrotationtoincrease
AT duyinqiao jumbocupinhipjointrenovationmaycausethecenterofrotationtoincrease
AT zhouyonggang jumbocupinhipjointrenovationmaycausethecenterofrotationtoincrease