Cargando…
Jumbo cup in hip joint renovation may cause the center of rotation to increase
BACKGROUND: Utilizing the large jumbo cup in revision total hip arthroplasty is an effective approach to cure many lacunar and segmental peripheral bone defects. However, with the use of the jumbo cup, the center of the hip joint may become elevated relative to the primary acetabulum, and the diamet...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Baishideng Publishing Group Inc
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8362550/ https://www.ncbi.nlm.nih.gov/pubmed/34434996 http://dx.doi.org/10.12998/wjcc.v9.i22.6300 |
_version_ | 1783738187573624832 |
---|---|
author | Peng, Ya-Wen Shen, Jun-Min Zhang, Yan-Chao Sun, Jing-Yang Du, Yin-Qiao Zhou, Yong-Gang |
author_facet | Peng, Ya-Wen Shen, Jun-Min Zhang, Yan-Chao Sun, Jing-Yang Du, Yin-Qiao Zhou, Yong-Gang |
author_sort | Peng, Ya-Wen |
collection | PubMed |
description | BACKGROUND: Utilizing the large jumbo cup in revision total hip arthroplasty is an effective approach to cure many lacunar and segmental peripheral bone defects. However, with the use of the jumbo cup, the center of the hip joint may become elevated relative to the primary acetabulum, and the diameter of the large cup is greater. AIM: To study the height and the significance of the elevation of the hip joint center. METHODS: Eighty-eight patients matched the criteria for this condition and were included in the study. The center height of the hip joint was measured relative to the opposite normal hip joint. The diameter of the jumbo cup was measured and checked according to operation notes, and the diameter of the jumbo cup was measured with a prosthesis label. Then, the horizontal and vertical centers of rotation were measured on the surgical side and opposite side. The average center height of the hip joint on the renovated side and the opposite side and the position of the hip cup relative to the teardrop were compared using a paired t-test. RESULTS: Radiometric analysis showed that the average hip joint center was elevated by 7.6 mm. The rotational center height delta of the renovated hip was 7.6 ± 5.6 mm, and there was an obvious difference between the two groups (P = 0.00). The difference in horizontal distance was 0.5 ± 5.1 mm (-11.5 -14.0 mm), and there was no obvious difference between the two groups (P = 0.38). According to the foreign standard, the rotational center height delta of the renovated hip was 7.5 ± 6.2 mm, and there was a significant difference between the two groups (P = 0.00). There was no obvious difference between the domestic and foreign standards (P > 0.05) between the two groups. CONCLUSION: The application of the jumbo cup elevates the rotational center of the hip joint, but it is feasible and effective to use the jumbo cup. |
format | Online Article Text |
id | pubmed-8362550 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Baishideng Publishing Group Inc |
record_format | MEDLINE/PubMed |
spelling | pubmed-83625502021-08-24 Jumbo cup in hip joint renovation may cause the center of rotation to increase Peng, Ya-Wen Shen, Jun-Min Zhang, Yan-Chao Sun, Jing-Yang Du, Yin-Qiao Zhou, Yong-Gang World J Clin Cases Retrospective Study BACKGROUND: Utilizing the large jumbo cup in revision total hip arthroplasty is an effective approach to cure many lacunar and segmental peripheral bone defects. However, with the use of the jumbo cup, the center of the hip joint may become elevated relative to the primary acetabulum, and the diameter of the large cup is greater. AIM: To study the height and the significance of the elevation of the hip joint center. METHODS: Eighty-eight patients matched the criteria for this condition and were included in the study. The center height of the hip joint was measured relative to the opposite normal hip joint. The diameter of the jumbo cup was measured and checked according to operation notes, and the diameter of the jumbo cup was measured with a prosthesis label. Then, the horizontal and vertical centers of rotation were measured on the surgical side and opposite side. The average center height of the hip joint on the renovated side and the opposite side and the position of the hip cup relative to the teardrop were compared using a paired t-test. RESULTS: Radiometric analysis showed that the average hip joint center was elevated by 7.6 mm. The rotational center height delta of the renovated hip was 7.6 ± 5.6 mm, and there was an obvious difference between the two groups (P = 0.00). The difference in horizontal distance was 0.5 ± 5.1 mm (-11.5 -14.0 mm), and there was no obvious difference between the two groups (P = 0.38). According to the foreign standard, the rotational center height delta of the renovated hip was 7.5 ± 6.2 mm, and there was a significant difference between the two groups (P = 0.00). There was no obvious difference between the domestic and foreign standards (P > 0.05) between the two groups. CONCLUSION: The application of the jumbo cup elevates the rotational center of the hip joint, but it is feasible and effective to use the jumbo cup. Baishideng Publishing Group Inc 2021-08-06 2021-08-06 /pmc/articles/PMC8362550/ /pubmed/34434996 http://dx.doi.org/10.12998/wjcc.v9.i22.6300 Text en ©The Author(s) 2021. Published by Baishideng Publishing Group Inc. All rights reserved. https://creativecommons.org/licenses/by-nc/4.0/This article is an open-access article that was selected by an in-house editor and fully peer-reviewed by external reviewers. It is distributed in accordance with the Creative Commons Attribution NonCommercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited and the use is non-commercial. See: http://creativecommons.org/Licenses/by-nc/4.0/ |
spellingShingle | Retrospective Study Peng, Ya-Wen Shen, Jun-Min Zhang, Yan-Chao Sun, Jing-Yang Du, Yin-Qiao Zhou, Yong-Gang Jumbo cup in hip joint renovation may cause the center of rotation to increase |
title | Jumbo cup in hip joint renovation may cause the center of rotation to increase |
title_full | Jumbo cup in hip joint renovation may cause the center of rotation to increase |
title_fullStr | Jumbo cup in hip joint renovation may cause the center of rotation to increase |
title_full_unstemmed | Jumbo cup in hip joint renovation may cause the center of rotation to increase |
title_short | Jumbo cup in hip joint renovation may cause the center of rotation to increase |
title_sort | jumbo cup in hip joint renovation may cause the center of rotation to increase |
topic | Retrospective Study |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8362550/ https://www.ncbi.nlm.nih.gov/pubmed/34434996 http://dx.doi.org/10.12998/wjcc.v9.i22.6300 |
work_keys_str_mv | AT pengyawen jumbocupinhipjointrenovationmaycausethecenterofrotationtoincrease AT shenjunmin jumbocupinhipjointrenovationmaycausethecenterofrotationtoincrease AT zhangyanchao jumbocupinhipjointrenovationmaycausethecenterofrotationtoincrease AT sunjingyang jumbocupinhipjointrenovationmaycausethecenterofrotationtoincrease AT duyinqiao jumbocupinhipjointrenovationmaycausethecenterofrotationtoincrease AT zhouyonggang jumbocupinhipjointrenovationmaycausethecenterofrotationtoincrease |