Cargando…
Direct visualization and correlation of liver stereotactic body radiation therapy treatment delivery accuracy with interfractional motion
This study used the visualization of hypo‐intense regions on liver‐specific MRI to directly quantify stereotactic body radiation therapy (SBRT) spatial delivery accuracy. Additionally, the interfractional motion of the liver region was determined and compared with the MRI‐based evaluation of liver S...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley and Sons Inc.
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8364285/ https://www.ncbi.nlm.nih.gov/pubmed/34240556 http://dx.doi.org/10.1002/acm2.13333 |
_version_ | 1783738501609553920 |
---|---|
author | Kuznetsova, S. Sinha, R. Thind, K. Ploquin, N. |
author_facet | Kuznetsova, S. Sinha, R. Thind, K. Ploquin, N. |
author_sort | Kuznetsova, S. |
collection | PubMed |
description | This study used the visualization of hypo‐intense regions on liver‐specific MRI to directly quantify stereotactic body radiation therapy (SBRT) spatial delivery accuracy. Additionally, the interfractional motion of the liver region was determined and compared with the MRI‐based evaluation of liver SBRT spatial treatment delivery accuracy. Primovist(®)‐enhanced MRI scans were acquired from 17 patients, 8–12 weeks following the completion of liver SBRT treatment. Direct visualization of radiation‐induced focal liver reaction in the form of hypo‐intensity was determined. The auto‐delineation approach was used to localize these regions, and center‐of‐mass (COM) discrepancy was quantified between the MRI hypo‐intensity and the CT‐based treatment plan. To assess the interfractional motion of the liver region, a planning CT was registered to a Cone Beam CT obtained before each treatment fraction. The interfractional motion assessed from this approach was then compared against the localized hypo‐intense MRI regions. The mean ± SD COM discrepancy was 1.4 ± 1.3 mm in the left‐right direction, 2.6 ± 1.8 mm in an anteroposterior direction, and 1.9 ± 2.6 mm in the craniocaudal direction. A high correlation was observed between interfractional motion of visualized hypo‐intensity and interfractional motion of planning treatment volume (PTV); the quantified Pearson correlation coefficient was 0.96. The lack of correlation was observed between Primovist(®) MRI‐based spatial accuracy and interfractional motion of the liver, where Pearson correlation coefficients ranged from −0.01 to −0.26. The highest random and systematic errors quantified from interfractional motion were in the craniocaudal direction. This work demonstrates a novel framework for the direct evaluation of liver SBRT spatial delivery accuracy. |
format | Online Article Text |
id | pubmed-8364285 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | John Wiley and Sons Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-83642852021-08-23 Direct visualization and correlation of liver stereotactic body radiation therapy treatment delivery accuracy with interfractional motion Kuznetsova, S. Sinha, R. Thind, K. Ploquin, N. J Appl Clin Med Phys Radiation Oncology Physics This study used the visualization of hypo‐intense regions on liver‐specific MRI to directly quantify stereotactic body radiation therapy (SBRT) spatial delivery accuracy. Additionally, the interfractional motion of the liver region was determined and compared with the MRI‐based evaluation of liver SBRT spatial treatment delivery accuracy. Primovist(®)‐enhanced MRI scans were acquired from 17 patients, 8–12 weeks following the completion of liver SBRT treatment. Direct visualization of radiation‐induced focal liver reaction in the form of hypo‐intensity was determined. The auto‐delineation approach was used to localize these regions, and center‐of‐mass (COM) discrepancy was quantified between the MRI hypo‐intensity and the CT‐based treatment plan. To assess the interfractional motion of the liver region, a planning CT was registered to a Cone Beam CT obtained before each treatment fraction. The interfractional motion assessed from this approach was then compared against the localized hypo‐intense MRI regions. The mean ± SD COM discrepancy was 1.4 ± 1.3 mm in the left‐right direction, 2.6 ± 1.8 mm in an anteroposterior direction, and 1.9 ± 2.6 mm in the craniocaudal direction. A high correlation was observed between interfractional motion of visualized hypo‐intensity and interfractional motion of planning treatment volume (PTV); the quantified Pearson correlation coefficient was 0.96. The lack of correlation was observed between Primovist(®) MRI‐based spatial accuracy and interfractional motion of the liver, where Pearson correlation coefficients ranged from −0.01 to −0.26. The highest random and systematic errors quantified from interfractional motion were in the craniocaudal direction. This work demonstrates a novel framework for the direct evaluation of liver SBRT spatial delivery accuracy. John Wiley and Sons Inc. 2021-07-09 /pmc/articles/PMC8364285/ /pubmed/34240556 http://dx.doi.org/10.1002/acm2.13333 Text en © 2021 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals LLC on behalf of American Association of Physicists in Medicine https://creativecommons.org/licenses/by/4.0/This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Radiation Oncology Physics Kuznetsova, S. Sinha, R. Thind, K. Ploquin, N. Direct visualization and correlation of liver stereotactic body radiation therapy treatment delivery accuracy with interfractional motion |
title | Direct visualization and correlation of liver stereotactic body radiation therapy treatment delivery accuracy with interfractional motion |
title_full | Direct visualization and correlation of liver stereotactic body radiation therapy treatment delivery accuracy with interfractional motion |
title_fullStr | Direct visualization and correlation of liver stereotactic body radiation therapy treatment delivery accuracy with interfractional motion |
title_full_unstemmed | Direct visualization and correlation of liver stereotactic body radiation therapy treatment delivery accuracy with interfractional motion |
title_short | Direct visualization and correlation of liver stereotactic body radiation therapy treatment delivery accuracy with interfractional motion |
title_sort | direct visualization and correlation of liver stereotactic body radiation therapy treatment delivery accuracy with interfractional motion |
topic | Radiation Oncology Physics |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8364285/ https://www.ncbi.nlm.nih.gov/pubmed/34240556 http://dx.doi.org/10.1002/acm2.13333 |
work_keys_str_mv | AT kuznetsovas directvisualizationandcorrelationofliverstereotacticbodyradiationtherapytreatmentdeliveryaccuracywithinterfractionalmotion AT sinhar directvisualizationandcorrelationofliverstereotacticbodyradiationtherapytreatmentdeliveryaccuracywithinterfractionalmotion AT thindk directvisualizationandcorrelationofliverstereotacticbodyradiationtherapytreatmentdeliveryaccuracywithinterfractionalmotion AT ploquinn directvisualizationandcorrelationofliverstereotacticbodyradiationtherapytreatmentdeliveryaccuracywithinterfractionalmotion |