Cargando…

Pseudocavitation sign at chest CT scan due to COVID-19 pneumonia: A report of 5 cases and literature review

Coronavirus disease 2019 (COVID-19) pneumonia computed tomography imaging features have been described in detail in many studies. The pseudocavitation sign has not been described in the previous COVID-19 studies. We present chest computed tomography scans of 5 reverse transcriptase-polymerase chain...

Descripción completa

Detalles Bibliográficos
Autores principales: Gurdal Kosem, Esra, Balik, Recep
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8364814/
https://www.ncbi.nlm.nih.gov/pubmed/34422146
http://dx.doi.org/10.1016/j.radcr.2021.08.034
_version_ 1783738592072302592
author Gurdal Kosem, Esra
Balik, Recep
author_facet Gurdal Kosem, Esra
Balik, Recep
author_sort Gurdal Kosem, Esra
collection PubMed
description Coronavirus disease 2019 (COVID-19) pneumonia computed tomography imaging features have been described in detail in many studies. The pseudocavitation sign has not been described in the previous COVID-19 studies. We present chest computed tomography scans of 5 reverse transcriptase-polymerase chain reaction positive patients with COVID-19 pneumonia who has bare areas among pulmonary infiltrates. All 5 also had previous scans with similarly sized low attenuated areas in the same location prior to the addition of pulmonary infiltrates. The pre-existing cystic changes had become remarkable due to the contrast around them after the pulmonary infiltrates added. Therefore, they should be termed as “pseodocavity” according to Fleischner Society glossary. Small air-containing spaces between pulmonary infiltrates have been termed in previous COVID-19 studies as a new sign called “round cystic changes/air bubble sign/vacuolar sign.” We would like to draw attention that the vacuolar sign and the synonyms may be the pseudocavity sign that is due to pre-existing changes rather than a new defined sign.
format Online
Article
Text
id pubmed-8364814
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-83648142021-08-16 Pseudocavitation sign at chest CT scan due to COVID-19 pneumonia: A report of 5 cases and literature review Gurdal Kosem, Esra Balik, Recep Radiol Case Rep Case Report Coronavirus disease 2019 (COVID-19) pneumonia computed tomography imaging features have been described in detail in many studies. The pseudocavitation sign has not been described in the previous COVID-19 studies. We present chest computed tomography scans of 5 reverse transcriptase-polymerase chain reaction positive patients with COVID-19 pneumonia who has bare areas among pulmonary infiltrates. All 5 also had previous scans with similarly sized low attenuated areas in the same location prior to the addition of pulmonary infiltrates. The pre-existing cystic changes had become remarkable due to the contrast around them after the pulmonary infiltrates added. Therefore, they should be termed as “pseodocavity” according to Fleischner Society glossary. Small air-containing spaces between pulmonary infiltrates have been termed in previous COVID-19 studies as a new sign called “round cystic changes/air bubble sign/vacuolar sign.” We would like to draw attention that the vacuolar sign and the synonyms may be the pseudocavity sign that is due to pre-existing changes rather than a new defined sign. Elsevier 2021-08-16 /pmc/articles/PMC8364814/ /pubmed/34422146 http://dx.doi.org/10.1016/j.radcr.2021.08.034 Text en © 2021 The Authors. Published by Elsevier Inc. on behalf of University of Washington. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Case Report
Gurdal Kosem, Esra
Balik, Recep
Pseudocavitation sign at chest CT scan due to COVID-19 pneumonia: A report of 5 cases and literature review
title Pseudocavitation sign at chest CT scan due to COVID-19 pneumonia: A report of 5 cases and literature review
title_full Pseudocavitation sign at chest CT scan due to COVID-19 pneumonia: A report of 5 cases and literature review
title_fullStr Pseudocavitation sign at chest CT scan due to COVID-19 pneumonia: A report of 5 cases and literature review
title_full_unstemmed Pseudocavitation sign at chest CT scan due to COVID-19 pneumonia: A report of 5 cases and literature review
title_short Pseudocavitation sign at chest CT scan due to COVID-19 pneumonia: A report of 5 cases and literature review
title_sort pseudocavitation sign at chest ct scan due to covid-19 pneumonia: a report of 5 cases and literature review
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8364814/
https://www.ncbi.nlm.nih.gov/pubmed/34422146
http://dx.doi.org/10.1016/j.radcr.2021.08.034
work_keys_str_mv AT gurdalkosemesra pseudocavitationsignatchestctscanduetocovid19pneumoniaareportof5casesandliteraturereview
AT balikrecep pseudocavitationsignatchestctscanduetocovid19pneumoniaareportof5casesandliteraturereview