Cargando…
Reliability and reproducibility of measurements in para-sagittal planes on sub-axial cervical vertebral bodies: a morphometric study of endplates in three-dimensional models
BACKGROUND: Dimensional measurements have been implemented on a variety of entities in morphological studies of the sub-axial cervical vertebral endplate. Despite great progress, little information between the mid-sagittal plane and bilateral uncinate processes has been acquired due to the lack of a...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8365898/ https://www.ncbi.nlm.nih.gov/pubmed/34399792 http://dx.doi.org/10.1186/s13018-021-02648-3 |
_version_ | 1783738803248168960 |
---|---|
author | Wang, Long Luo, Hao T. Lu, Wei Cai, Xing Bo Yu, Chen Lu, Sheng |
author_facet | Wang, Long Luo, Hao T. Lu, Wei Cai, Xing Bo Yu, Chen Lu, Sheng |
author_sort | Wang, Long |
collection | PubMed |
description | BACKGROUND: Dimensional measurements have been implemented on a variety of entities in morphological studies of the sub-axial cervical vertebral endplate. Despite great progress, little information between the mid-sagittal plane and bilateral uncinate processes has been acquired due to the lack of a reliable method to determine the para-sagittal planes. Also, few studies of this region are available. We proposed a new approach to defining the para-sagittal planes on a 3D cervical vertebral body model; in this approach, dimensions can be measured in a specific plane. The aim of this study was to assess the inter-observer and intra-observer reliability of the measurements in different sagittal planes on sub-axial cervical vertebral endplates of 3D models. METHODS: We established mid-sagittal and bilateral quarter para-sagittal planes on the 3D model of a sub-axial cervical vertebral body based on landmarks labeled on the surface. By intersecting the vertebral body with the planes, three curves located at the three para-sagittal planes were generated. Linear dimensions were measured on every curve by two observers separately, and in total, 24 sub-axial cervical spines were included in the study. The first observer (O1) performed the procedure twice with an interval of 2 weeks. The paired t test, Wilcoxon matched-pairs signed-rank test and the interclass correlation coefficient (ICC) were employed to evaluate the inter- and intra-observer reliability of the proposed method. RESULTS: There were no significant differences in most intra- and inter-observer comparisons, and higher non-significant proportions were found in the intra-observer comparisons than in comparisons between different observers. The interclass correlation coefficients (ICCs) in the measurements were excellent (> 0.75) in most circumstances, and the values in intra-observer comparisons were higher than those in inter-observer comparisons. CONCLUSIONS: In this study, we proposed an approach to determine the bilateral quarter para-sagittal planes in a 3D cervical vertebral body model; the results demonstrated that the method is reproducible with high intra- and inter-observer agreement. |
format | Online Article Text |
id | pubmed-8365898 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-83658982021-08-17 Reliability and reproducibility of measurements in para-sagittal planes on sub-axial cervical vertebral bodies: a morphometric study of endplates in three-dimensional models Wang, Long Luo, Hao T. Lu, Wei Cai, Xing Bo Yu, Chen Lu, Sheng J Orthop Surg Res Research Article BACKGROUND: Dimensional measurements have been implemented on a variety of entities in morphological studies of the sub-axial cervical vertebral endplate. Despite great progress, little information between the mid-sagittal plane and bilateral uncinate processes has been acquired due to the lack of a reliable method to determine the para-sagittal planes. Also, few studies of this region are available. We proposed a new approach to defining the para-sagittal planes on a 3D cervical vertebral body model; in this approach, dimensions can be measured in a specific plane. The aim of this study was to assess the inter-observer and intra-observer reliability of the measurements in different sagittal planes on sub-axial cervical vertebral endplates of 3D models. METHODS: We established mid-sagittal and bilateral quarter para-sagittal planes on the 3D model of a sub-axial cervical vertebral body based on landmarks labeled on the surface. By intersecting the vertebral body with the planes, three curves located at the three para-sagittal planes were generated. Linear dimensions were measured on every curve by two observers separately, and in total, 24 sub-axial cervical spines were included in the study. The first observer (O1) performed the procedure twice with an interval of 2 weeks. The paired t test, Wilcoxon matched-pairs signed-rank test and the interclass correlation coefficient (ICC) were employed to evaluate the inter- and intra-observer reliability of the proposed method. RESULTS: There were no significant differences in most intra- and inter-observer comparisons, and higher non-significant proportions were found in the intra-observer comparisons than in comparisons between different observers. The interclass correlation coefficients (ICCs) in the measurements were excellent (> 0.75) in most circumstances, and the values in intra-observer comparisons were higher than those in inter-observer comparisons. CONCLUSIONS: In this study, we proposed an approach to determine the bilateral quarter para-sagittal planes in a 3D cervical vertebral body model; the results demonstrated that the method is reproducible with high intra- and inter-observer agreement. BioMed Central 2021-08-16 /pmc/articles/PMC8365898/ /pubmed/34399792 http://dx.doi.org/10.1186/s13018-021-02648-3 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Article Wang, Long Luo, Hao T. Lu, Wei Cai, Xing Bo Yu, Chen Lu, Sheng Reliability and reproducibility of measurements in para-sagittal planes on sub-axial cervical vertebral bodies: a morphometric study of endplates in three-dimensional models |
title | Reliability and reproducibility of measurements in para-sagittal planes on sub-axial cervical vertebral bodies: a morphometric study of endplates in three-dimensional models |
title_full | Reliability and reproducibility of measurements in para-sagittal planes on sub-axial cervical vertebral bodies: a morphometric study of endplates in three-dimensional models |
title_fullStr | Reliability and reproducibility of measurements in para-sagittal planes on sub-axial cervical vertebral bodies: a morphometric study of endplates in three-dimensional models |
title_full_unstemmed | Reliability and reproducibility of measurements in para-sagittal planes on sub-axial cervical vertebral bodies: a morphometric study of endplates in three-dimensional models |
title_short | Reliability and reproducibility of measurements in para-sagittal planes on sub-axial cervical vertebral bodies: a morphometric study of endplates in three-dimensional models |
title_sort | reliability and reproducibility of measurements in para-sagittal planes on sub-axial cervical vertebral bodies: a morphometric study of endplates in three-dimensional models |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8365898/ https://www.ncbi.nlm.nih.gov/pubmed/34399792 http://dx.doi.org/10.1186/s13018-021-02648-3 |
work_keys_str_mv | AT wanglong reliabilityandreproducibilityofmeasurementsinparasagittalplanesonsubaxialcervicalvertebralbodiesamorphometricstudyofendplatesinthreedimensionalmodels AT luohaot reliabilityandreproducibilityofmeasurementsinparasagittalplanesonsubaxialcervicalvertebralbodiesamorphometricstudyofendplatesinthreedimensionalmodels AT luwei reliabilityandreproducibilityofmeasurementsinparasagittalplanesonsubaxialcervicalvertebralbodiesamorphometricstudyofendplatesinthreedimensionalmodels AT caixingbo reliabilityandreproducibilityofmeasurementsinparasagittalplanesonsubaxialcervicalvertebralbodiesamorphometricstudyofendplatesinthreedimensionalmodels AT yuchen reliabilityandreproducibilityofmeasurementsinparasagittalplanesonsubaxialcervicalvertebralbodiesamorphometricstudyofendplatesinthreedimensionalmodels AT lusheng reliabilityandreproducibilityofmeasurementsinparasagittalplanesonsubaxialcervicalvertebralbodiesamorphometricstudyofendplatesinthreedimensionalmodels |