Cargando…

Evaluation of the Long-Term Cost-Effectiveness of the Dexcom G6 Continuous Glucose Monitor versus Self-Monitoring of Blood Glucose in People with Type 1 Diabetes in Canada

BACKGROUND: The Dexcom G6 real-time continuous glucose monitoring (RT-CGM) system is one of the most sophisticated RT-CGM systems developed to date and became available in Canada in 2019. A health economic analysis was performed to determine the long-term cost-effectiveness of the Dexcom G6 RT-CGM s...

Descripción completa

Detalles Bibliográficos
Autores principales: Roze, Stephane, Isitt, John J, Smith-Palmer, Jayne, Lynch, Peter
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Dove 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8366033/
https://www.ncbi.nlm.nih.gov/pubmed/34408456
http://dx.doi.org/10.2147/CEOR.S304395
_version_ 1783738827318231040
author Roze, Stephane
Isitt, John J
Smith-Palmer, Jayne
Lynch, Peter
author_facet Roze, Stephane
Isitt, John J
Smith-Palmer, Jayne
Lynch, Peter
author_sort Roze, Stephane
collection PubMed
description BACKGROUND: The Dexcom G6 real-time continuous glucose monitoring (RT-CGM) system is one of the most sophisticated RT-CGM systems developed to date and became available in Canada in 2019. A health economic analysis was performed to determine the long-term cost-effectiveness of the Dexcom G6 RT-CGM system versus SMBG in adults with type 1 diabetes (T1D) in Canada. METHODS: The analysis was performed using the IQVIA Core Diabetes Model. Based on clinical trial data, patients with mean baseline HbA1c of 8.6% were assumed to have a HbA1c reduction of 1.0% with RT-CGM versus 0.4% reduction with SMBG. RT-CGM was also associated with a quality of life (QoL) benefit owing to reduced incidence of hypoglycemia, reduced fear of hypoglycemia (FoH) and elimination of fingerstick testing. Direct medical costs were sourced from published literature, and inflated to 2019 Canadian dollars (CAD). RESULTS: Dexcom G6 RT-CGM was projected to improve mean quality-adjusted life expectancy by 2.09 quality-adjusted life years (QALYs) relative to SMBG (15.52 versus 13.43 QALYs) but mean total lifetime cots were CAD 35,353 higher with RT-CGM (CAD 227,357 versus CAD 192,004) resulting in an incremental cost-effectiveness ratio (ICER) of CAD 16,931 per QALY gained. Sensitivity analyses revealed that assumptions relating to the QoL benefit associated with reduced FoH and the elimination of fingerstick testing with RT-CGM as well as SMBG usage and change in HbA1c were the key drivers of cost-effectiveness. CONCLUSION: For adults with T1D in Canada, RT-CGM is associated with improved glycemic control and QoL benefits owing to a reduced FoH and elimination of the requirement for fingerstick testing and over a lifetime time horizon is cost-effective relative to SMBG.
format Online
Article
Text
id pubmed-8366033
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Dove
record_format MEDLINE/PubMed
spelling pubmed-83660332021-08-17 Evaluation of the Long-Term Cost-Effectiveness of the Dexcom G6 Continuous Glucose Monitor versus Self-Monitoring of Blood Glucose in People with Type 1 Diabetes in Canada Roze, Stephane Isitt, John J Smith-Palmer, Jayne Lynch, Peter Clinicoecon Outcomes Res Original Research BACKGROUND: The Dexcom G6 real-time continuous glucose monitoring (RT-CGM) system is one of the most sophisticated RT-CGM systems developed to date and became available in Canada in 2019. A health economic analysis was performed to determine the long-term cost-effectiveness of the Dexcom G6 RT-CGM system versus SMBG in adults with type 1 diabetes (T1D) in Canada. METHODS: The analysis was performed using the IQVIA Core Diabetes Model. Based on clinical trial data, patients with mean baseline HbA1c of 8.6% were assumed to have a HbA1c reduction of 1.0% with RT-CGM versus 0.4% reduction with SMBG. RT-CGM was also associated with a quality of life (QoL) benefit owing to reduced incidence of hypoglycemia, reduced fear of hypoglycemia (FoH) and elimination of fingerstick testing. Direct medical costs were sourced from published literature, and inflated to 2019 Canadian dollars (CAD). RESULTS: Dexcom G6 RT-CGM was projected to improve mean quality-adjusted life expectancy by 2.09 quality-adjusted life years (QALYs) relative to SMBG (15.52 versus 13.43 QALYs) but mean total lifetime cots were CAD 35,353 higher with RT-CGM (CAD 227,357 versus CAD 192,004) resulting in an incremental cost-effectiveness ratio (ICER) of CAD 16,931 per QALY gained. Sensitivity analyses revealed that assumptions relating to the QoL benefit associated with reduced FoH and the elimination of fingerstick testing with RT-CGM as well as SMBG usage and change in HbA1c were the key drivers of cost-effectiveness. CONCLUSION: For adults with T1D in Canada, RT-CGM is associated with improved glycemic control and QoL benefits owing to a reduced FoH and elimination of the requirement for fingerstick testing and over a lifetime time horizon is cost-effective relative to SMBG. Dove 2021-08-11 /pmc/articles/PMC8366033/ /pubmed/34408456 http://dx.doi.org/10.2147/CEOR.S304395 Text en © 2021 Roze et al. https://creativecommons.org/licenses/by-nc/3.0/This work is published and licensed by Dove Medical Press Limited. The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution – Non Commercial (unported, v3.0) License (http://creativecommons.org/licenses/by-nc/3.0/ (https://creativecommons.org/licenses/by-nc/3.0/) ). By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed. For permission for commercial use of this work, please see paragraphs 4.2 and 5 of our Terms (https://www.dovepress.com/terms.php).
spellingShingle Original Research
Roze, Stephane
Isitt, John J
Smith-Palmer, Jayne
Lynch, Peter
Evaluation of the Long-Term Cost-Effectiveness of the Dexcom G6 Continuous Glucose Monitor versus Self-Monitoring of Blood Glucose in People with Type 1 Diabetes in Canada
title Evaluation of the Long-Term Cost-Effectiveness of the Dexcom G6 Continuous Glucose Monitor versus Self-Monitoring of Blood Glucose in People with Type 1 Diabetes in Canada
title_full Evaluation of the Long-Term Cost-Effectiveness of the Dexcom G6 Continuous Glucose Monitor versus Self-Monitoring of Blood Glucose in People with Type 1 Diabetes in Canada
title_fullStr Evaluation of the Long-Term Cost-Effectiveness of the Dexcom G6 Continuous Glucose Monitor versus Self-Monitoring of Blood Glucose in People with Type 1 Diabetes in Canada
title_full_unstemmed Evaluation of the Long-Term Cost-Effectiveness of the Dexcom G6 Continuous Glucose Monitor versus Self-Monitoring of Blood Glucose in People with Type 1 Diabetes in Canada
title_short Evaluation of the Long-Term Cost-Effectiveness of the Dexcom G6 Continuous Glucose Monitor versus Self-Monitoring of Blood Glucose in People with Type 1 Diabetes in Canada
title_sort evaluation of the long-term cost-effectiveness of the dexcom g6 continuous glucose monitor versus self-monitoring of blood glucose in people with type 1 diabetes in canada
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8366033/
https://www.ncbi.nlm.nih.gov/pubmed/34408456
http://dx.doi.org/10.2147/CEOR.S304395
work_keys_str_mv AT rozestephane evaluationofthelongtermcosteffectivenessofthedexcomg6continuousglucosemonitorversusselfmonitoringofbloodglucoseinpeoplewithtype1diabetesincanada
AT isittjohnj evaluationofthelongtermcosteffectivenessofthedexcomg6continuousglucosemonitorversusselfmonitoringofbloodglucoseinpeoplewithtype1diabetesincanada
AT smithpalmerjayne evaluationofthelongtermcosteffectivenessofthedexcomg6continuousglucosemonitorversusselfmonitoringofbloodglucoseinpeoplewithtype1diabetesincanada
AT lynchpeter evaluationofthelongtermcosteffectivenessofthedexcomg6continuousglucosemonitorversusselfmonitoringofbloodglucoseinpeoplewithtype1diabetesincanada