Cargando…

Reliability and accuracy of individual Alberta Stroke Program Early CT Score regions using a medical and a smartphone reading system in a telestroke network

INTRODUCTION: The aim of this study was to assess individual regions of the Alberta Stroke Program Early CT Score in noncontrast head computed tomography interpretations using a smartphone in a telestroke network, by comparison to a medical monitor. METHODS: The review board of our institution appro...

Descripción completa

Detalles Bibliográficos
Autores principales: Salazar, Antonio J, Useche, Nicolás, Granja, Manuel, Bermúdez, Sonia, Morillo, Aníbal J, Torres, Oscar, Rueda, Natalia, Ropero, Brenda
Formato: Online Artículo Texto
Lenguaje:English
Publicado: SAGE Publications 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8366140/
https://www.ncbi.nlm.nih.gov/pubmed/31635531
http://dx.doi.org/10.1177/1357633X19881863
_version_ 1783738851181723648
author Salazar, Antonio J
Useche, Nicolás
Granja, Manuel
Bermúdez, Sonia
Morillo, Aníbal J
Torres, Oscar
Rueda, Natalia
Ropero, Brenda
author_facet Salazar, Antonio J
Useche, Nicolás
Granja, Manuel
Bermúdez, Sonia
Morillo, Aníbal J
Torres, Oscar
Rueda, Natalia
Ropero, Brenda
author_sort Salazar, Antonio J
collection PubMed
description INTRODUCTION: The aim of this study was to assess individual regions of the Alberta Stroke Program Early CT Score in noncontrast head computed tomography interpretations using a smartphone in a telestroke network, by comparison to a medical monitor. METHODS: The review board of our institution approved this retrospective study. A factorial design with 188 patients, four radiologists and two reading systems was used. Accuracy and reliability were evaluated. RESULTS: Very good interobserver agreements were observed on the total Alberta Stroke Program Early CT Score for both the medical and smartphone reading systems, with intraclass correlation coefficients of 0.91 and 0.84 respectively. Interobserver agreements were moderate to very good for the medical reading system (all intraclass correlation coefficients >0.74), whereas they were fair to very good for the smartphone (intraclass correlation coefficients ranged from 0.31–0.81). All intraobserver agreements were good (intraclass correlation coefficient >0.64), except for internal capsule (0.48) and M2 (0.55) regions. The areas under the receiver-operating curve ranged from 0.69–0.89 for the medical system, while for the smartphone ranged from 0.44–0.86. No statistical differences were observed between medical and smartphone reading systems for each region (all p > 0.05). DISCUSSION: If radiologists are better trained in the evaluation of the lesions in the insula, the internal capsule and the M2 regions, the total and the dichotomised Alberta Stroke Program Early CT Score will be more precise. Hence, ruling out contraindications to thrombolysis administration will be improved, allowing assessment of head computed tomography in a telestroke network using a smartphone to be a common practice.
format Online
Article
Text
id pubmed-8366140
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher SAGE Publications
record_format MEDLINE/PubMed
spelling pubmed-83661402021-08-17 Reliability and accuracy of individual Alberta Stroke Program Early CT Score regions using a medical and a smartphone reading system in a telestroke network Salazar, Antonio J Useche, Nicolás Granja, Manuel Bermúdez, Sonia Morillo, Aníbal J Torres, Oscar Rueda, Natalia Ropero, Brenda J Telemed Telecare RESEARCH/Original Articles INTRODUCTION: The aim of this study was to assess individual regions of the Alberta Stroke Program Early CT Score in noncontrast head computed tomography interpretations using a smartphone in a telestroke network, by comparison to a medical monitor. METHODS: The review board of our institution approved this retrospective study. A factorial design with 188 patients, four radiologists and two reading systems was used. Accuracy and reliability were evaluated. RESULTS: Very good interobserver agreements were observed on the total Alberta Stroke Program Early CT Score for both the medical and smartphone reading systems, with intraclass correlation coefficients of 0.91 and 0.84 respectively. Interobserver agreements were moderate to very good for the medical reading system (all intraclass correlation coefficients >0.74), whereas they were fair to very good for the smartphone (intraclass correlation coefficients ranged from 0.31–0.81). All intraobserver agreements were good (intraclass correlation coefficient >0.64), except for internal capsule (0.48) and M2 (0.55) regions. The areas under the receiver-operating curve ranged from 0.69–0.89 for the medical system, while for the smartphone ranged from 0.44–0.86. No statistical differences were observed between medical and smartphone reading systems for each region (all p > 0.05). DISCUSSION: If radiologists are better trained in the evaluation of the lesions in the insula, the internal capsule and the M2 regions, the total and the dichotomised Alberta Stroke Program Early CT Score will be more precise. Hence, ruling out contraindications to thrombolysis administration will be improved, allowing assessment of head computed tomography in a telestroke network using a smartphone to be a common practice. SAGE Publications 2019-10-21 2021-09 /pmc/articles/PMC8366140/ /pubmed/31635531 http://dx.doi.org/10.1177/1357633X19881863 Text en © The Author(s) 2019 https://creativecommons.org/licenses/by-nc/4.0/This article is distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 License (http://www.creativecommons.org/licenses/by-nc/4.0/ (https://creativecommons.org/licenses/by-nc/4.0/) ) which permits non-commercial use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access pages (https://us.sagepub.com/en-us/nam/open-access-at-sage).
spellingShingle RESEARCH/Original Articles
Salazar, Antonio J
Useche, Nicolás
Granja, Manuel
Bermúdez, Sonia
Morillo, Aníbal J
Torres, Oscar
Rueda, Natalia
Ropero, Brenda
Reliability and accuracy of individual Alberta Stroke Program Early CT Score regions using a medical and a smartphone reading system in a telestroke network
title Reliability and accuracy of individual Alberta Stroke Program Early CT Score regions using a medical and a smartphone reading system in a telestroke network
title_full Reliability and accuracy of individual Alberta Stroke Program Early CT Score regions using a medical and a smartphone reading system in a telestroke network
title_fullStr Reliability and accuracy of individual Alberta Stroke Program Early CT Score regions using a medical and a smartphone reading system in a telestroke network
title_full_unstemmed Reliability and accuracy of individual Alberta Stroke Program Early CT Score regions using a medical and a smartphone reading system in a telestroke network
title_short Reliability and accuracy of individual Alberta Stroke Program Early CT Score regions using a medical and a smartphone reading system in a telestroke network
title_sort reliability and accuracy of individual alberta stroke program early ct score regions using a medical and a smartphone reading system in a telestroke network
topic RESEARCH/Original Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8366140/
https://www.ncbi.nlm.nih.gov/pubmed/31635531
http://dx.doi.org/10.1177/1357633X19881863
work_keys_str_mv AT salazarantonioj reliabilityandaccuracyofindividualalbertastrokeprogramearlyctscoreregionsusingamedicalandasmartphonereadingsysteminatelestrokenetwork
AT usechenicolas reliabilityandaccuracyofindividualalbertastrokeprogramearlyctscoreregionsusingamedicalandasmartphonereadingsysteminatelestrokenetwork
AT granjamanuel reliabilityandaccuracyofindividualalbertastrokeprogramearlyctscoreregionsusingamedicalandasmartphonereadingsysteminatelestrokenetwork
AT bermudezsonia reliabilityandaccuracyofindividualalbertastrokeprogramearlyctscoreregionsusingamedicalandasmartphonereadingsysteminatelestrokenetwork
AT morilloanibalj reliabilityandaccuracyofindividualalbertastrokeprogramearlyctscoreregionsusingamedicalandasmartphonereadingsysteminatelestrokenetwork
AT torresoscar reliabilityandaccuracyofindividualalbertastrokeprogramearlyctscoreregionsusingamedicalandasmartphonereadingsysteminatelestrokenetwork
AT ruedanatalia reliabilityandaccuracyofindividualalbertastrokeprogramearlyctscoreregionsusingamedicalandasmartphonereadingsysteminatelestrokenetwork
AT roperobrenda reliabilityandaccuracyofindividualalbertastrokeprogramearlyctscoreregionsusingamedicalandasmartphonereadingsysteminatelestrokenetwork