Using the Diaphragm as a Tracking Surrogate in CyberKnife Synchrony Treatment

BACKGROUND: In this study, we assessed the usefulness of diaphragm surrogate tracking in the design of a respiratory model for CyberKnife Synchrony treatment of lung tumors. MATERIAL/METHODS: Twenty-four patients with lung cancer who underwent stereotactic body radiotherapy with CyberKnife between A...

Descripción completa

Detalles Bibliográficos
Autores principales: Li, Guo-quan, Yang, Jing, Wang, Yan, Qiu, Mengjun, Ding, Zeyu, Zhang, Sheng, Yang, Sheng-li, Peng, Zhenjun
Formato: Online Artículo Texto
Lenguaje:English
Publicado: International Scientific Literature, Inc. 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8366302/
https://www.ncbi.nlm.nih.gov/pubmed/34379616
http://dx.doi.org/10.12659/MSM.930139
Descripción
Sumario:BACKGROUND: In this study, we assessed the usefulness of diaphragm surrogate tracking in the design of a respiratory model for CyberKnife Synchrony treatment of lung tumors. MATERIAL/METHODS: Twenty-four patients with lung cancer who underwent stereotactic body radiotherapy with CyberKnife between April and November 2019 were enrolled. Simulation plans for each patient were designed using Xsight lung tracking (XLT) and diaphragm tracking (DT) methods, and tumor visualization tests were performed. The offset consistency at each respiratory phase was analyzed. The relative distance along the alignment center of the superior-inferior (SI) axis in the 2 projections (dxAB), uncertainty (%), and average standard error (AvgStdErr)/maximum standard error (MAXStdErr) were also analyzed. RESULTS: Bland-Altman analyses revealed that the average differences±standard deviation (SD) between XLT and DT tracking methods were 0.4±2.9 mm, 0.3±4.35 mm, and -1.8±6.8 mm for the SI, left-right (LR), and anterior-posterior (AP) directions, respectively. These results indicated high consistency in the SI and LR directions and poor consistency in the AP direction. Uncertainty differed significantly between XLT and DT (22.813±5.721% vs 9.384±3.799%; t=−5.236; P=0.0008), but we found no significant differences in dxAB, AvgStdErr, or MAXStdErr. CONCLUSIONS: In the majority of cases, motion tracking by XLT and DT was consistent and synchronized in the SI directions, but not in the LR and AP directions. With a boundary margin of 0.3±4.35 mm and 1.8±6.8 mm for the LR and AP directions, DT may contribute to better implementation of CyberKnife Synchrony treatment in patients with lung tumors near the diaphragm that cannot be seen in tumor visualization tests.