State of The Art in Breast Intraoperative Electron Radiation Therapy After Intraoperative Ultrasound Introduction
BACKGROUND: Breast intraoperative electron radiation therapy (B-IOERT) can be used in clinical practice both as elective irradiation (partial breast irradiation – APBI) in low risk breast cancer patients, and as an anticipated boost. The procedure generally includes the use of a shielding disk betwe...
Autores principales: | , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Sciendo
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8366729/ https://www.ncbi.nlm.nih.gov/pubmed/33991470 http://dx.doi.org/10.2478/raon-2021-0023 |
_version_ | 1783738939431976960 |
---|---|
author | Vidali, Cristiana Severgnini, Mara Bellio, Gabriele Giudici, Fabiola Milan, Vittorino Pellin, Zaira Savatovic, Sara Scomersi, Serena Fastner, Gerd Ciabattoni, Antonella Bortul, Marina |
author_facet | Vidali, Cristiana Severgnini, Mara Bellio, Gabriele Giudici, Fabiola Milan, Vittorino Pellin, Zaira Savatovic, Sara Scomersi, Serena Fastner, Gerd Ciabattoni, Antonella Bortul, Marina |
author_sort | Vidali, Cristiana |
collection | PubMed |
description | BACKGROUND: Breast intraoperative electron radiation therapy (B-IOERT) can be used in clinical practice both as elective irradiation (partial breast irradiation – APBI) in low risk breast cancer patients, and as an anticipated boost. The procedure generally includes the use of a shielding disk between the residual breast and the pectoralis fascia for the protection of the tissues underneath the target volume. The aim of the study was to evaluate the role of intraoperative ultrasound (IOUS) in improving the quality of B-IOERT. PATIENTS AND METHODS: B-IOERT was introduced in Trieste in 2012 and its technique was improved in 2014 with IOUS. Both, needle and IOUS were used to measure target thickness and the latter was used even to check the correct position of the shielding disk. The primary endpoint of the study was the evaluation of the effectiveness of IOUS in reducing the risk of a disk misalignment related to B-IOERT and the secondary endpoint was the analysis of acute and late toxicity, by comparing two groups of patients treated with IOERT as a boost, either measured with IOUS and needle (Group 1) or with needle alone (Group 2). Acute and late toxicity were evaluated by validated scoring systems. RESULTS: From the institutional patients who were treated between June 2012 and October 2019, 109 were eligible for this study (corresponding to 110 cases, as one patients underwent bilateral conservative surgery and bilateral B-IOERT). Of these, 38 were allocated to group 1 and 72 to group 2. The target thickness measured with the IOUS probe and with the needle were similar (mean difference of 0.1 mm, p = 0.38). The percentage of patients in which the shield was perfectly aligned after IOUS introduction increased from 23% to more than 70%. Moreover, patients treated after IOUS guidance had less acute toxicity (36.8% vs. 48.6%, p = 0.33) from radiation therapy, which reached no statistical significance. Late toxicity turned out to be similar regardless of the use of IOUS guidance: 39.5% vs. 37.5% (p = 0.99). CONCLUSIONS: IOUS showed to be accurate in measuring the target depth and decrease the misalignment between collimator and disk. Furthermore there was an absolute decrease in acute toxicity, even though not statistically significant, in the group of women who underwent B-IOERT with IOUS guidance. |
format | Online Article Text |
id | pubmed-8366729 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Sciendo |
record_format | MEDLINE/PubMed |
spelling | pubmed-83667292021-09-01 State of The Art in Breast Intraoperative Electron Radiation Therapy After Intraoperative Ultrasound Introduction Vidali, Cristiana Severgnini, Mara Bellio, Gabriele Giudici, Fabiola Milan, Vittorino Pellin, Zaira Savatovic, Sara Scomersi, Serena Fastner, Gerd Ciabattoni, Antonella Bortul, Marina Radiol Oncol Research Article BACKGROUND: Breast intraoperative electron radiation therapy (B-IOERT) can be used in clinical practice both as elective irradiation (partial breast irradiation – APBI) in low risk breast cancer patients, and as an anticipated boost. The procedure generally includes the use of a shielding disk between the residual breast and the pectoralis fascia for the protection of the tissues underneath the target volume. The aim of the study was to evaluate the role of intraoperative ultrasound (IOUS) in improving the quality of B-IOERT. PATIENTS AND METHODS: B-IOERT was introduced in Trieste in 2012 and its technique was improved in 2014 with IOUS. Both, needle and IOUS were used to measure target thickness and the latter was used even to check the correct position of the shielding disk. The primary endpoint of the study was the evaluation of the effectiveness of IOUS in reducing the risk of a disk misalignment related to B-IOERT and the secondary endpoint was the analysis of acute and late toxicity, by comparing two groups of patients treated with IOERT as a boost, either measured with IOUS and needle (Group 1) or with needle alone (Group 2). Acute and late toxicity were evaluated by validated scoring systems. RESULTS: From the institutional patients who were treated between June 2012 and October 2019, 109 were eligible for this study (corresponding to 110 cases, as one patients underwent bilateral conservative surgery and bilateral B-IOERT). Of these, 38 were allocated to group 1 and 72 to group 2. The target thickness measured with the IOUS probe and with the needle were similar (mean difference of 0.1 mm, p = 0.38). The percentage of patients in which the shield was perfectly aligned after IOUS introduction increased from 23% to more than 70%. Moreover, patients treated after IOUS guidance had less acute toxicity (36.8% vs. 48.6%, p = 0.33) from radiation therapy, which reached no statistical significance. Late toxicity turned out to be similar regardless of the use of IOUS guidance: 39.5% vs. 37.5% (p = 0.99). CONCLUSIONS: IOUS showed to be accurate in measuring the target depth and decrease the misalignment between collimator and disk. Furthermore there was an absolute decrease in acute toxicity, even though not statistically significant, in the group of women who underwent B-IOERT with IOUS guidance. Sciendo 2021-05-16 /pmc/articles/PMC8366729/ /pubmed/33991470 http://dx.doi.org/10.2478/raon-2021-0023 Text en © 2021 Cristiana Vidali, Mara Severgnini, Gabriele Bellio, Fabiola Giudici, Vittorino Milan, Zaira Pellin, Sara Savatovic, Serena Scomersi, Gerd Fastner, Antonella Ciabattoni, Marina Bortul, published by Sciendo https://creativecommons.org/licenses/by-nc-nd/3.0/This work is licensed under the Creative Commons Attribution-NonCommercial-NoDerivatives 3.0 License. |
spellingShingle | Research Article Vidali, Cristiana Severgnini, Mara Bellio, Gabriele Giudici, Fabiola Milan, Vittorino Pellin, Zaira Savatovic, Sara Scomersi, Serena Fastner, Gerd Ciabattoni, Antonella Bortul, Marina State of The Art in Breast Intraoperative Electron Radiation Therapy After Intraoperative Ultrasound Introduction |
title | State of The Art in Breast Intraoperative Electron Radiation Therapy After Intraoperative Ultrasound Introduction |
title_full | State of The Art in Breast Intraoperative Electron Radiation Therapy After Intraoperative Ultrasound Introduction |
title_fullStr | State of The Art in Breast Intraoperative Electron Radiation Therapy After Intraoperative Ultrasound Introduction |
title_full_unstemmed | State of The Art in Breast Intraoperative Electron Radiation Therapy After Intraoperative Ultrasound Introduction |
title_short | State of The Art in Breast Intraoperative Electron Radiation Therapy After Intraoperative Ultrasound Introduction |
title_sort | state of the art in breast intraoperative electron radiation therapy after intraoperative ultrasound introduction |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8366729/ https://www.ncbi.nlm.nih.gov/pubmed/33991470 http://dx.doi.org/10.2478/raon-2021-0023 |
work_keys_str_mv | AT vidalicristiana stateoftheartinbreastintraoperativeelectronradiationtherapyafterintraoperativeultrasoundintroduction AT severgninimara stateoftheartinbreastintraoperativeelectronradiationtherapyafterintraoperativeultrasoundintroduction AT belliogabriele stateoftheartinbreastintraoperativeelectronradiationtherapyafterintraoperativeultrasoundintroduction AT giudicifabiola stateoftheartinbreastintraoperativeelectronradiationtherapyafterintraoperativeultrasoundintroduction AT milanvittorino stateoftheartinbreastintraoperativeelectronradiationtherapyafterintraoperativeultrasoundintroduction AT pellinzaira stateoftheartinbreastintraoperativeelectronradiationtherapyafterintraoperativeultrasoundintroduction AT savatovicsara stateoftheartinbreastintraoperativeelectronradiationtherapyafterintraoperativeultrasoundintroduction AT scomersiserena stateoftheartinbreastintraoperativeelectronradiationtherapyafterintraoperativeultrasoundintroduction AT fastnergerd stateoftheartinbreastintraoperativeelectronradiationtherapyafterintraoperativeultrasoundintroduction AT ciabattoniantonella stateoftheartinbreastintraoperativeelectronradiationtherapyafterintraoperativeultrasoundintroduction AT bortulmarina stateoftheartinbreastintraoperativeelectronradiationtherapyafterintraoperativeultrasoundintroduction |