Cargando…

Acceptability of Intervention Design Factors in mHealth Intervention Research: Experimental Factorial Study

BACKGROUND: With the growing interest in mobile health (mHealth), behavioral medicine researchers are increasingly conducting intervention studies that use mobile technology (eg, to support healthy behavior change). Such studies’ scientific premises are often sound, yet there is a dearth of implemen...

Descripción completa

Detalles Bibliográficos
Autores principales: Materia, Frank T, Smyth, Joshua M
Formato: Online Artículo Texto
Lenguaje:English
Publicado: JMIR Publications 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8367134/
https://www.ncbi.nlm.nih.gov/pubmed/34309563
http://dx.doi.org/10.2196/23303
_version_ 1783739017327542272
author Materia, Frank T
Smyth, Joshua M
author_facet Materia, Frank T
Smyth, Joshua M
author_sort Materia, Frank T
collection PubMed
description BACKGROUND: With the growing interest in mobile health (mHealth), behavioral medicine researchers are increasingly conducting intervention studies that use mobile technology (eg, to support healthy behavior change). Such studies’ scientific premises are often sound, yet there is a dearth of implementational data on which to base mHealth research methodologies. Notably, mHealth approaches must be designed to be acceptable to research participants to support meaningful engagement, but little empirical data about design factors influencing acceptability in such studies exist. OBJECTIVE: This study aims to evaluate the impact of two common design factors in mHealth intervention research—requiring multiple devices (eg, a study smartphone and wrist sensor) relative to requiring a single device and providing individually tailored feedback as opposed to generic content—on reported participant acceptability. METHODS: A diverse US adult convenience sample (female: 104/255, 40.8%; White: 208/255, 81.6%; aged 18-74 years) was recruited to complete a web-based experiment. A 2×2 factorial design (number of devices×nature of feedback) was used. A learning module explaining the necessary concepts (eg, behavior change interventions, acceptability, and tailored content) was presented, followed by four vignettes (representing each factorial cell) that were presented to participants in a random order. The vignettes each described a hypothetical mHealth intervention study featuring different combinations of the two design factors (requiring a single device vs multiple devices and providing tailored vs generic content). Participants rated acceptability dimensions (interest, benefit, enjoyment, utility, confidence, difficulty, and overall likelihood of participating) for each study presented. RESULTS: Reported interest, benefit, enjoyment, confidence in completing study requirements, and perceived utility were each significantly higher for studies featuring tailored (vs generic) content, and the overall estimate of the likelihood of participation was significantly higher. Ratings of interest, benefit, and perceived utility were significantly higher for studies requiring multiple devices (vs a single device); however, multiple device studies also had significantly lower ratings of confidence in completing study requirements, and participation was seen as more difficult and was associated with a lower estimated likelihood of participation. The two factors did not exhibit any evidence of statistical interactions in any of the outcomes tested. CONCLUSIONS: The results suggest that potential research participants are sensitive to mHealth design factors. These mHealth intervention design factors may be important for initial perceptions of acceptability (in research or clinical settings). This, in turn, may be associated with participant (eg, self) selection processes, differential compliance with study or treatment processes, or retention over time.
format Online
Article
Text
id pubmed-8367134
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher JMIR Publications
record_format MEDLINE/PubMed
spelling pubmed-83671342021-08-24 Acceptability of Intervention Design Factors in mHealth Intervention Research: Experimental Factorial Study Materia, Frank T Smyth, Joshua M JMIR Mhealth Uhealth Original Paper BACKGROUND: With the growing interest in mobile health (mHealth), behavioral medicine researchers are increasingly conducting intervention studies that use mobile technology (eg, to support healthy behavior change). Such studies’ scientific premises are often sound, yet there is a dearth of implementational data on which to base mHealth research methodologies. Notably, mHealth approaches must be designed to be acceptable to research participants to support meaningful engagement, but little empirical data about design factors influencing acceptability in such studies exist. OBJECTIVE: This study aims to evaluate the impact of two common design factors in mHealth intervention research—requiring multiple devices (eg, a study smartphone and wrist sensor) relative to requiring a single device and providing individually tailored feedback as opposed to generic content—on reported participant acceptability. METHODS: A diverse US adult convenience sample (female: 104/255, 40.8%; White: 208/255, 81.6%; aged 18-74 years) was recruited to complete a web-based experiment. A 2×2 factorial design (number of devices×nature of feedback) was used. A learning module explaining the necessary concepts (eg, behavior change interventions, acceptability, and tailored content) was presented, followed by four vignettes (representing each factorial cell) that were presented to participants in a random order. The vignettes each described a hypothetical mHealth intervention study featuring different combinations of the two design factors (requiring a single device vs multiple devices and providing tailored vs generic content). Participants rated acceptability dimensions (interest, benefit, enjoyment, utility, confidence, difficulty, and overall likelihood of participating) for each study presented. RESULTS: Reported interest, benefit, enjoyment, confidence in completing study requirements, and perceived utility were each significantly higher for studies featuring tailored (vs generic) content, and the overall estimate of the likelihood of participation was significantly higher. Ratings of interest, benefit, and perceived utility were significantly higher for studies requiring multiple devices (vs a single device); however, multiple device studies also had significantly lower ratings of confidence in completing study requirements, and participation was seen as more difficult and was associated with a lower estimated likelihood of participation. The two factors did not exhibit any evidence of statistical interactions in any of the outcomes tested. CONCLUSIONS: The results suggest that potential research participants are sensitive to mHealth design factors. These mHealth intervention design factors may be important for initial perceptions of acceptability (in research or clinical settings). This, in turn, may be associated with participant (eg, self) selection processes, differential compliance with study or treatment processes, or retention over time. JMIR Publications 2021-07-26 /pmc/articles/PMC8367134/ /pubmed/34309563 http://dx.doi.org/10.2196/23303 Text en ©Frank T Materia, Joshua M Smyth. Originally published in JMIR mHealth and uHealth (https://mhealth.jmir.org), 26.07.2021. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work, first published in JMIR mHealth and uHealth, is properly cited. The complete bibliographic information, a link to the original publication on https://mhealth.jmir.org/, as well as this copyright and license information must be included.
spellingShingle Original Paper
Materia, Frank T
Smyth, Joshua M
Acceptability of Intervention Design Factors in mHealth Intervention Research: Experimental Factorial Study
title Acceptability of Intervention Design Factors in mHealth Intervention Research: Experimental Factorial Study
title_full Acceptability of Intervention Design Factors in mHealth Intervention Research: Experimental Factorial Study
title_fullStr Acceptability of Intervention Design Factors in mHealth Intervention Research: Experimental Factorial Study
title_full_unstemmed Acceptability of Intervention Design Factors in mHealth Intervention Research: Experimental Factorial Study
title_short Acceptability of Intervention Design Factors in mHealth Intervention Research: Experimental Factorial Study
title_sort acceptability of intervention design factors in mhealth intervention research: experimental factorial study
topic Original Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8367134/
https://www.ncbi.nlm.nih.gov/pubmed/34309563
http://dx.doi.org/10.2196/23303
work_keys_str_mv AT materiafrankt acceptabilityofinterventiondesignfactorsinmhealthinterventionresearchexperimentalfactorialstudy
AT smythjoshuam acceptabilityofinterventiondesignfactorsinmhealthinterventionresearchexperimentalfactorialstudy