Cargando…

The Utility of Real-Time Remote Auscultation Using a Bluetooth-Connected Electronic Stethoscope: Open-Label Randomized Controlled Pilot Trial

BACKGROUND: The urgent need for telemedicine has become clear in the COVID-19 pandemic. To facilitate telemedicine, the development and improvement of remote examination systems are required. A system combining an electronic stethoscope and Bluetooth connectivity is a promising option for remote aus...

Descripción completa

Detalles Bibliográficos
Autores principales: Hirosawa, Takanobu, Harada, Yukinori, Ikenoya, Kohei, Kakimoto, Shintaro, Aizawa, Yuki, Shimizu, Taro
Formato: Online Artículo Texto
Lenguaje:English
Publicado: JMIR Publications 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8367161/
https://www.ncbi.nlm.nih.gov/pubmed/34313598
http://dx.doi.org/10.2196/23109
_version_ 1783739023728050176
author Hirosawa, Takanobu
Harada, Yukinori
Ikenoya, Kohei
Kakimoto, Shintaro
Aizawa, Yuki
Shimizu, Taro
author_facet Hirosawa, Takanobu
Harada, Yukinori
Ikenoya, Kohei
Kakimoto, Shintaro
Aizawa, Yuki
Shimizu, Taro
author_sort Hirosawa, Takanobu
collection PubMed
description BACKGROUND: The urgent need for telemedicine has become clear in the COVID-19 pandemic. To facilitate telemedicine, the development and improvement of remote examination systems are required. A system combining an electronic stethoscope and Bluetooth connectivity is a promising option for remote auscultation in clinics and hospitals. However, the utility of such systems remains unknown. OBJECTIVE: This study was conducted to assess the utility of real-time auscultation using a Bluetooth-connected electronic stethoscope compared to that of classical auscultation, using lung and cardiology patient simulators. METHODS: This was an open-label, randomized controlled trial including senior residents and faculty in the department of general internal medicine of a university hospital. The only exclusion criterion was a refusal to participate. This study consisted of 2 parts: lung auscultation and cardiac auscultation. Each part contained a tutorial session and a test session. All participants attended a tutorial session, in which they listened to 15 sounds on the simulator using a classic stethoscope and were told the correct classification. Thereafter, participants were randomly assigned to either the real-time remote auscultation group (intervention group) or the classical auscultation group (control group) for test sessions. In the test sessions, participants had to classify a series of 10 lung sounds and 10 cardiac sounds, depending on the study part. The intervention group listened to the sounds remotely using the electronic stethoscope, a Bluetooth transmitter, and a wireless, noise-canceling, stereo headset. The control group listened to the sounds directly using a traditional stethoscope. The primary outcome was the test score, and the secondary outcomes were the rates of correct answers for each sound. RESULTS: In total, 20 participants were included. There were no differences in age, sex, and years from graduation between the 2 groups in each part. The overall test score of lung auscultation in the intervention group (80/110, 72.7%) was not different from that in the control group (71/90, 78.9%; P=.32). The only lung sound for which the correct answer rate differed between groups was that of pleural friction rubs (P=.03); it was lower in the intervention group (3/11, 27%) than in the control group (7/9, 78%). The overall test score for cardiac auscultation in the intervention group (50/60, 83.3%) was not different from that in the control group (119/140, 85.0%; P=.77). There was no cardiac sound for which the correct answer rate differed between groups. CONCLUSIONS: The utility of a real-time remote auscultation system using a Bluetooth-connected electronic stethoscope was comparable to that of direct auscultation using a classic stethoscope, except for classification of pleural friction rubs. This means that most of the real world’s essential cardiopulmonary sounds could be classified by a real-time remote auscultation system using a Bluetooth-connected electronic stethoscope. TRIAL REGISTRATION: UMIN-CTR UMIN000040828; https://tinyurl.com/r24j2p6s and UMIN-CTR UMIN000041601; https://tinyurl.com/bsax3j5f
format Online
Article
Text
id pubmed-8367161
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher JMIR Publications
record_format MEDLINE/PubMed
spelling pubmed-83671612021-08-24 The Utility of Real-Time Remote Auscultation Using a Bluetooth-Connected Electronic Stethoscope: Open-Label Randomized Controlled Pilot Trial Hirosawa, Takanobu Harada, Yukinori Ikenoya, Kohei Kakimoto, Shintaro Aizawa, Yuki Shimizu, Taro JMIR Mhealth Uhealth Original Paper BACKGROUND: The urgent need for telemedicine has become clear in the COVID-19 pandemic. To facilitate telemedicine, the development and improvement of remote examination systems are required. A system combining an electronic stethoscope and Bluetooth connectivity is a promising option for remote auscultation in clinics and hospitals. However, the utility of such systems remains unknown. OBJECTIVE: This study was conducted to assess the utility of real-time auscultation using a Bluetooth-connected electronic stethoscope compared to that of classical auscultation, using lung and cardiology patient simulators. METHODS: This was an open-label, randomized controlled trial including senior residents and faculty in the department of general internal medicine of a university hospital. The only exclusion criterion was a refusal to participate. This study consisted of 2 parts: lung auscultation and cardiac auscultation. Each part contained a tutorial session and a test session. All participants attended a tutorial session, in which they listened to 15 sounds on the simulator using a classic stethoscope and were told the correct classification. Thereafter, participants were randomly assigned to either the real-time remote auscultation group (intervention group) or the classical auscultation group (control group) for test sessions. In the test sessions, participants had to classify a series of 10 lung sounds and 10 cardiac sounds, depending on the study part. The intervention group listened to the sounds remotely using the electronic stethoscope, a Bluetooth transmitter, and a wireless, noise-canceling, stereo headset. The control group listened to the sounds directly using a traditional stethoscope. The primary outcome was the test score, and the secondary outcomes were the rates of correct answers for each sound. RESULTS: In total, 20 participants were included. There were no differences in age, sex, and years from graduation between the 2 groups in each part. The overall test score of lung auscultation in the intervention group (80/110, 72.7%) was not different from that in the control group (71/90, 78.9%; P=.32). The only lung sound for which the correct answer rate differed between groups was that of pleural friction rubs (P=.03); it was lower in the intervention group (3/11, 27%) than in the control group (7/9, 78%). The overall test score for cardiac auscultation in the intervention group (50/60, 83.3%) was not different from that in the control group (119/140, 85.0%; P=.77). There was no cardiac sound for which the correct answer rate differed between groups. CONCLUSIONS: The utility of a real-time remote auscultation system using a Bluetooth-connected electronic stethoscope was comparable to that of direct auscultation using a classic stethoscope, except for classification of pleural friction rubs. This means that most of the real world’s essential cardiopulmonary sounds could be classified by a real-time remote auscultation system using a Bluetooth-connected electronic stethoscope. TRIAL REGISTRATION: UMIN-CTR UMIN000040828; https://tinyurl.com/r24j2p6s and UMIN-CTR UMIN000041601; https://tinyurl.com/bsax3j5f JMIR Publications 2021-07-27 /pmc/articles/PMC8367161/ /pubmed/34313598 http://dx.doi.org/10.2196/23109 Text en ©Takanobu Hirosawa, Yukinori Harada, Kohei Ikenoya, Shintaro Kakimoto, Yuki Aizawa, Taro Shimizu. Originally published in JMIR mHealth and uHealth (https://mhealth.jmir.org), 27.07.2021. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work, first published in JMIR mHealth and uHealth, is properly cited. The complete bibliographic information, a link to the original publication on https://mhealth.jmir.org/, as well as this copyright and license information must be included.
spellingShingle Original Paper
Hirosawa, Takanobu
Harada, Yukinori
Ikenoya, Kohei
Kakimoto, Shintaro
Aizawa, Yuki
Shimizu, Taro
The Utility of Real-Time Remote Auscultation Using a Bluetooth-Connected Electronic Stethoscope: Open-Label Randomized Controlled Pilot Trial
title The Utility of Real-Time Remote Auscultation Using a Bluetooth-Connected Electronic Stethoscope: Open-Label Randomized Controlled Pilot Trial
title_full The Utility of Real-Time Remote Auscultation Using a Bluetooth-Connected Electronic Stethoscope: Open-Label Randomized Controlled Pilot Trial
title_fullStr The Utility of Real-Time Remote Auscultation Using a Bluetooth-Connected Electronic Stethoscope: Open-Label Randomized Controlled Pilot Trial
title_full_unstemmed The Utility of Real-Time Remote Auscultation Using a Bluetooth-Connected Electronic Stethoscope: Open-Label Randomized Controlled Pilot Trial
title_short The Utility of Real-Time Remote Auscultation Using a Bluetooth-Connected Electronic Stethoscope: Open-Label Randomized Controlled Pilot Trial
title_sort utility of real-time remote auscultation using a bluetooth-connected electronic stethoscope: open-label randomized controlled pilot trial
topic Original Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8367161/
https://www.ncbi.nlm.nih.gov/pubmed/34313598
http://dx.doi.org/10.2196/23109
work_keys_str_mv AT hirosawatakanobu theutilityofrealtimeremoteauscultationusingabluetoothconnectedelectronicstethoscopeopenlabelrandomizedcontrolledpilottrial
AT haradayukinori theutilityofrealtimeremoteauscultationusingabluetoothconnectedelectronicstethoscopeopenlabelrandomizedcontrolledpilottrial
AT ikenoyakohei theutilityofrealtimeremoteauscultationusingabluetoothconnectedelectronicstethoscopeopenlabelrandomizedcontrolledpilottrial
AT kakimotoshintaro theutilityofrealtimeremoteauscultationusingabluetoothconnectedelectronicstethoscopeopenlabelrandomizedcontrolledpilottrial
AT aizawayuki theutilityofrealtimeremoteauscultationusingabluetoothconnectedelectronicstethoscopeopenlabelrandomizedcontrolledpilottrial
AT shimizutaro theutilityofrealtimeremoteauscultationusingabluetoothconnectedelectronicstethoscopeopenlabelrandomizedcontrolledpilottrial
AT hirosawatakanobu utilityofrealtimeremoteauscultationusingabluetoothconnectedelectronicstethoscopeopenlabelrandomizedcontrolledpilottrial
AT haradayukinori utilityofrealtimeremoteauscultationusingabluetoothconnectedelectronicstethoscopeopenlabelrandomizedcontrolledpilottrial
AT ikenoyakohei utilityofrealtimeremoteauscultationusingabluetoothconnectedelectronicstethoscopeopenlabelrandomizedcontrolledpilottrial
AT kakimotoshintaro utilityofrealtimeremoteauscultationusingabluetoothconnectedelectronicstethoscopeopenlabelrandomizedcontrolledpilottrial
AT aizawayuki utilityofrealtimeremoteauscultationusingabluetoothconnectedelectronicstethoscopeopenlabelrandomizedcontrolledpilottrial
AT shimizutaro utilityofrealtimeremoteauscultationusingabluetoothconnectedelectronicstethoscopeopenlabelrandomizedcontrolledpilottrial