Cargando…

Dual-foci fast-scanning photoacoustic microscopy with 3.2-MHz A-line rate

We report fiber-based dual-foci fast-scanning OR-PAM that can double the scanning rate without compromising the imaging resolution, the field of view, and the detection sensitivity. To achieve fast scanning speed, the OR-PAM system uses a single-axis water-immersible resonant scanning mirror that ca...

Descripción completa

Detalles Bibliográficos
Autores principales: Chen, Jiangbo, Zhang, Yachao, Bai, Songnan, Zhu, Jingyi, Chirarattananon, Pakpong, Ni, Kai, Zhou, Qian, Wang, Lidai
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8367837/
https://www.ncbi.nlm.nih.gov/pubmed/34430201
http://dx.doi.org/10.1016/j.pacs.2021.100292
_version_ 1783739097226936320
author Chen, Jiangbo
Zhang, Yachao
Bai, Songnan
Zhu, Jingyi
Chirarattananon, Pakpong
Ni, Kai
Zhou, Qian
Wang, Lidai
author_facet Chen, Jiangbo
Zhang, Yachao
Bai, Songnan
Zhu, Jingyi
Chirarattananon, Pakpong
Ni, Kai
Zhou, Qian
Wang, Lidai
author_sort Chen, Jiangbo
collection PubMed
description We report fiber-based dual-foci fast-scanning OR-PAM that can double the scanning rate without compromising the imaging resolution, the field of view, and the detection sensitivity. To achieve fast scanning speed, the OR-PAM system uses a single-axis water-immersible resonant scanning mirror that can confocally scan the optical and acoustic beams at 1018 Hz with a 3-mm range. Pulse energies of 45∼100-nJ are sufficient for acquiring vascular and oxygen-saturation images. The dual-foci method can double the B-scan rate to 2036 Hz. Using two lasers and stimulated Raman scattering, we achieve dual-wavelength excitation on both foci, and the total A-line rate is 3.2-MHz. In in vivo experiments, we inject epinephrine and monitor the hemodynamic and oxygen saturation response in the peripheral vessels at 1.7 Hz over 2.5 × 6.7 mm(2). Dual-foci OR-PAM offers a new imaging tool for the study of fast physiological and pathological changes.
format Online
Article
Text
id pubmed-8367837
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-83678372021-08-23 Dual-foci fast-scanning photoacoustic microscopy with 3.2-MHz A-line rate Chen, Jiangbo Zhang, Yachao Bai, Songnan Zhu, Jingyi Chirarattananon, Pakpong Ni, Kai Zhou, Qian Wang, Lidai Photoacoustics Research Article We report fiber-based dual-foci fast-scanning OR-PAM that can double the scanning rate without compromising the imaging resolution, the field of view, and the detection sensitivity. To achieve fast scanning speed, the OR-PAM system uses a single-axis water-immersible resonant scanning mirror that can confocally scan the optical and acoustic beams at 1018 Hz with a 3-mm range. Pulse energies of 45∼100-nJ are sufficient for acquiring vascular and oxygen-saturation images. The dual-foci method can double the B-scan rate to 2036 Hz. Using two lasers and stimulated Raman scattering, we achieve dual-wavelength excitation on both foci, and the total A-line rate is 3.2-MHz. In in vivo experiments, we inject epinephrine and monitor the hemodynamic and oxygen saturation response in the peripheral vessels at 1.7 Hz over 2.5 × 6.7 mm(2). Dual-foci OR-PAM offers a new imaging tool for the study of fast physiological and pathological changes. Elsevier 2021-08-09 /pmc/articles/PMC8367837/ /pubmed/34430201 http://dx.doi.org/10.1016/j.pacs.2021.100292 Text en © 2021 The Authors https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Research Article
Chen, Jiangbo
Zhang, Yachao
Bai, Songnan
Zhu, Jingyi
Chirarattananon, Pakpong
Ni, Kai
Zhou, Qian
Wang, Lidai
Dual-foci fast-scanning photoacoustic microscopy with 3.2-MHz A-line rate
title Dual-foci fast-scanning photoacoustic microscopy with 3.2-MHz A-line rate
title_full Dual-foci fast-scanning photoacoustic microscopy with 3.2-MHz A-line rate
title_fullStr Dual-foci fast-scanning photoacoustic microscopy with 3.2-MHz A-line rate
title_full_unstemmed Dual-foci fast-scanning photoacoustic microscopy with 3.2-MHz A-line rate
title_short Dual-foci fast-scanning photoacoustic microscopy with 3.2-MHz A-line rate
title_sort dual-foci fast-scanning photoacoustic microscopy with 3.2-mhz a-line rate
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8367837/
https://www.ncbi.nlm.nih.gov/pubmed/34430201
http://dx.doi.org/10.1016/j.pacs.2021.100292
work_keys_str_mv AT chenjiangbo dualfocifastscanningphotoacousticmicroscopywith32mhzalinerate
AT zhangyachao dualfocifastscanningphotoacousticmicroscopywith32mhzalinerate
AT baisongnan dualfocifastscanningphotoacousticmicroscopywith32mhzalinerate
AT zhujingyi dualfocifastscanningphotoacousticmicroscopywith32mhzalinerate
AT chirarattananonpakpong dualfocifastscanningphotoacousticmicroscopywith32mhzalinerate
AT nikai dualfocifastscanningphotoacousticmicroscopywith32mhzalinerate
AT zhouqian dualfocifastscanningphotoacousticmicroscopywith32mhzalinerate
AT wanglidai dualfocifastscanningphotoacousticmicroscopywith32mhzalinerate