Cargando…

Inaccuracy of a non-invasive estimation of pulmonary vascular resistance assessed by cardiovascular magnetic resonance in heart failure patients

Pulmonary vascular resistance (PVR) is a marker of pulmonary vascular remodeling. A non-invasive model assessed by cardiovascular magnetic resonance (CMR) has been proposed to estimate PVR. However, its accuracy has not yet been evaluated in patients with heart failure. We prospectively included 108...

Descripción completa

Detalles Bibliográficos
Autores principales: Rumiz, Eva, Cubillos, Andrés, Vilar, Juan Vicente, García, Pilar, Berenguer, Alberto, Fácila, Lorenzo, Valero, Ernesto, Vidal, Verónica, Morell, Salvador, Nuñez, Julio
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nature Publishing Group UK 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8368081/
https://www.ncbi.nlm.nih.gov/pubmed/34400680
http://dx.doi.org/10.1038/s41598-021-95897-5
_version_ 1783739147818631168
author Rumiz, Eva
Cubillos, Andrés
Vilar, Juan Vicente
García, Pilar
Berenguer, Alberto
Fácila, Lorenzo
Valero, Ernesto
Vidal, Verónica
Morell, Salvador
Nuñez, Julio
author_facet Rumiz, Eva
Cubillos, Andrés
Vilar, Juan Vicente
García, Pilar
Berenguer, Alberto
Fácila, Lorenzo
Valero, Ernesto
Vidal, Verónica
Morell, Salvador
Nuñez, Julio
author_sort Rumiz, Eva
collection PubMed
description Pulmonary vascular resistance (PVR) is a marker of pulmonary vascular remodeling. A non-invasive model assessed by cardiovascular magnetic resonance (CMR) has been proposed to estimate PVR. However, its accuracy has not yet been evaluated in patients with heart failure. We prospectively included 108 patients admitted with acute heart failure (AHF), in whom a right heart catheterization (RHC) and CMR were performed at the same day. PVR was estimated by CMR applying the model: PVR = 19.38 − [4.62 × Ln pulmonary artery average velocity (in cm/s)] − [0.08 × right ventricle ejection fraction (in %)], and by RHC using standard formulae. The median age of the cohort was 67 years (interquartile range 58–73), and 34% were females. The median of PVR assessed by RHC and CMR were 2.2 WU (1.5–4) and 5 WU (3.4–7), respectively. We found a weak correlation between invasive PVR and PVR assessed by CMR (Spearman r = 0.21, p = 0.02). The area under the ROC curve for PVR assessed by CMR to detect PVR ≥ 3 WU was 0.57, 95% confidence interval (CI): 0.47–0.68. In patients with AHF, the non-invasive estimation of PVR using CMR shows poor accuracy, as well as a limited capacity to discriminate increased PVR values.
format Online
Article
Text
id pubmed-8368081
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Nature Publishing Group UK
record_format MEDLINE/PubMed
spelling pubmed-83680812021-08-17 Inaccuracy of a non-invasive estimation of pulmonary vascular resistance assessed by cardiovascular magnetic resonance in heart failure patients Rumiz, Eva Cubillos, Andrés Vilar, Juan Vicente García, Pilar Berenguer, Alberto Fácila, Lorenzo Valero, Ernesto Vidal, Verónica Morell, Salvador Nuñez, Julio Sci Rep Article Pulmonary vascular resistance (PVR) is a marker of pulmonary vascular remodeling. A non-invasive model assessed by cardiovascular magnetic resonance (CMR) has been proposed to estimate PVR. However, its accuracy has not yet been evaluated in patients with heart failure. We prospectively included 108 patients admitted with acute heart failure (AHF), in whom a right heart catheterization (RHC) and CMR were performed at the same day. PVR was estimated by CMR applying the model: PVR = 19.38 − [4.62 × Ln pulmonary artery average velocity (in cm/s)] − [0.08 × right ventricle ejection fraction (in %)], and by RHC using standard formulae. The median age of the cohort was 67 years (interquartile range 58–73), and 34% were females. The median of PVR assessed by RHC and CMR were 2.2 WU (1.5–4) and 5 WU (3.4–7), respectively. We found a weak correlation between invasive PVR and PVR assessed by CMR (Spearman r = 0.21, p = 0.02). The area under the ROC curve for PVR assessed by CMR to detect PVR ≥ 3 WU was 0.57, 95% confidence interval (CI): 0.47–0.68. In patients with AHF, the non-invasive estimation of PVR using CMR shows poor accuracy, as well as a limited capacity to discriminate increased PVR values. Nature Publishing Group UK 2021-08-16 /pmc/articles/PMC8368081/ /pubmed/34400680 http://dx.doi.org/10.1038/s41598-021-95897-5 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Article
Rumiz, Eva
Cubillos, Andrés
Vilar, Juan Vicente
García, Pilar
Berenguer, Alberto
Fácila, Lorenzo
Valero, Ernesto
Vidal, Verónica
Morell, Salvador
Nuñez, Julio
Inaccuracy of a non-invasive estimation of pulmonary vascular resistance assessed by cardiovascular magnetic resonance in heart failure patients
title Inaccuracy of a non-invasive estimation of pulmonary vascular resistance assessed by cardiovascular magnetic resonance in heart failure patients
title_full Inaccuracy of a non-invasive estimation of pulmonary vascular resistance assessed by cardiovascular magnetic resonance in heart failure patients
title_fullStr Inaccuracy of a non-invasive estimation of pulmonary vascular resistance assessed by cardiovascular magnetic resonance in heart failure patients
title_full_unstemmed Inaccuracy of a non-invasive estimation of pulmonary vascular resistance assessed by cardiovascular magnetic resonance in heart failure patients
title_short Inaccuracy of a non-invasive estimation of pulmonary vascular resistance assessed by cardiovascular magnetic resonance in heart failure patients
title_sort inaccuracy of a non-invasive estimation of pulmonary vascular resistance assessed by cardiovascular magnetic resonance in heart failure patients
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8368081/
https://www.ncbi.nlm.nih.gov/pubmed/34400680
http://dx.doi.org/10.1038/s41598-021-95897-5
work_keys_str_mv AT rumizeva inaccuracyofanoninvasiveestimationofpulmonaryvascularresistanceassessedbycardiovascularmagneticresonanceinheartfailurepatients
AT cubillosandres inaccuracyofanoninvasiveestimationofpulmonaryvascularresistanceassessedbycardiovascularmagneticresonanceinheartfailurepatients
AT vilarjuanvicente inaccuracyofanoninvasiveestimationofpulmonaryvascularresistanceassessedbycardiovascularmagneticresonanceinheartfailurepatients
AT garciapilar inaccuracyofanoninvasiveestimationofpulmonaryvascularresistanceassessedbycardiovascularmagneticresonanceinheartfailurepatients
AT berengueralberto inaccuracyofanoninvasiveestimationofpulmonaryvascularresistanceassessedbycardiovascularmagneticresonanceinheartfailurepatients
AT facilalorenzo inaccuracyofanoninvasiveestimationofpulmonaryvascularresistanceassessedbycardiovascularmagneticresonanceinheartfailurepatients
AT valeroernesto inaccuracyofanoninvasiveestimationofpulmonaryvascularresistanceassessedbycardiovascularmagneticresonanceinheartfailurepatients
AT vidalveronica inaccuracyofanoninvasiveestimationofpulmonaryvascularresistanceassessedbycardiovascularmagneticresonanceinheartfailurepatients
AT morellsalvador inaccuracyofanoninvasiveestimationofpulmonaryvascularresistanceassessedbycardiovascularmagneticresonanceinheartfailurepatients
AT nunezjulio inaccuracyofanoninvasiveestimationofpulmonaryvascularresistanceassessedbycardiovascularmagneticresonanceinheartfailurepatients