Cargando…

Proposed Geometrical Tool for Cases of Laterally Adapted Tibial Tubercle during Total Knee Replacement

The alignment of tibial component in total knee replacement operation must be achieved in three planes to ensure optimum results. In coronal plane, the alignment depends on three anatomical landmarks. These landmarks are tibial tuberosity, leg shin, and midtalar point. In eastern community, people g...

Descripción completa

Detalles Bibliográficos
Autores principales: Khairy, Umaima R., Hamandi, Sadiq J., Abid Ali, Ahmed S.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8369185/
https://www.ncbi.nlm.nih.gov/pubmed/34413983
http://dx.doi.org/10.1155/2021/5244034
_version_ 1783739239011188736
author Khairy, Umaima R.
Hamandi, Sadiq J.
Abid Ali, Ahmed S.
author_facet Khairy, Umaima R.
Hamandi, Sadiq J.
Abid Ali, Ahmed S.
author_sort Khairy, Umaima R.
collection PubMed
description The alignment of tibial component in total knee replacement operation must be achieved in three planes to ensure optimum results. In coronal plane, the alignment depends on three anatomical landmarks. These landmarks are tibial tuberosity, leg shin, and midtalar point. In eastern community, people get used to sit cross-legged which causes additional tension in the quadriceps muscle which is attached distally to the tibial tuberosity. This tension causes adaptation of the tuberosity laterally. Tuberosity adaptation causes the three anatomical landmarks being not collinear. In this work, eight cases of lateral adapted tubercle were diagnosed of this condition before the surgery and their X-ray images after the surgery were checked regarding tibial alignment. Tibial alignment has been checked by measuring the medial proximal tibial angle (MPTA) which is the angle between the mechanical tibial axis and the tibial component plateau. MPTAs for the eight cases were (86.9°–93.6°). Three cases had MPTA less than 90° indicating varus alignment and five of them had MPTA more than 90° indicating valgus alignment. A geometrical tool was designed using the DesignSpark Mechanical software as a proposed solution to solve the adaptation problem. The tool can give a method for fixing the tibial component precisely without any varus\valgus malalignment.
format Online
Article
Text
id pubmed-8369185
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-83691852021-08-18 Proposed Geometrical Tool for Cases of Laterally Adapted Tibial Tubercle during Total Knee Replacement Khairy, Umaima R. Hamandi, Sadiq J. Abid Ali, Ahmed S. Adv Orthop Research Article The alignment of tibial component in total knee replacement operation must be achieved in three planes to ensure optimum results. In coronal plane, the alignment depends on three anatomical landmarks. These landmarks are tibial tuberosity, leg shin, and midtalar point. In eastern community, people get used to sit cross-legged which causes additional tension in the quadriceps muscle which is attached distally to the tibial tuberosity. This tension causes adaptation of the tuberosity laterally. Tuberosity adaptation causes the three anatomical landmarks being not collinear. In this work, eight cases of lateral adapted tubercle were diagnosed of this condition before the surgery and their X-ray images after the surgery were checked regarding tibial alignment. Tibial alignment has been checked by measuring the medial proximal tibial angle (MPTA) which is the angle between the mechanical tibial axis and the tibial component plateau. MPTAs for the eight cases were (86.9°–93.6°). Three cases had MPTA less than 90° indicating varus alignment and five of them had MPTA more than 90° indicating valgus alignment. A geometrical tool was designed using the DesignSpark Mechanical software as a proposed solution to solve the adaptation problem. The tool can give a method for fixing the tibial component precisely without any varus\valgus malalignment. Hindawi 2021-08-07 /pmc/articles/PMC8369185/ /pubmed/34413983 http://dx.doi.org/10.1155/2021/5244034 Text en Copyright © 2021 Umaima R. Khairy et al. https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Khairy, Umaima R.
Hamandi, Sadiq J.
Abid Ali, Ahmed S.
Proposed Geometrical Tool for Cases of Laterally Adapted Tibial Tubercle during Total Knee Replacement
title Proposed Geometrical Tool for Cases of Laterally Adapted Tibial Tubercle during Total Knee Replacement
title_full Proposed Geometrical Tool for Cases of Laterally Adapted Tibial Tubercle during Total Knee Replacement
title_fullStr Proposed Geometrical Tool for Cases of Laterally Adapted Tibial Tubercle during Total Knee Replacement
title_full_unstemmed Proposed Geometrical Tool for Cases of Laterally Adapted Tibial Tubercle during Total Knee Replacement
title_short Proposed Geometrical Tool for Cases of Laterally Adapted Tibial Tubercle during Total Knee Replacement
title_sort proposed geometrical tool for cases of laterally adapted tibial tubercle during total knee replacement
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8369185/
https://www.ncbi.nlm.nih.gov/pubmed/34413983
http://dx.doi.org/10.1155/2021/5244034
work_keys_str_mv AT khairyumaimar proposedgeometricaltoolforcasesoflaterallyadaptedtibialtubercleduringtotalkneereplacement
AT hamandisadiqj proposedgeometricaltoolforcasesoflaterallyadaptedtibialtubercleduringtotalkneereplacement
AT abidaliahmeds proposedgeometricaltoolforcasesoflaterallyadaptedtibialtubercleduringtotalkneereplacement