Cargando…
Titanium alloy cannulated screws and biodegradable magnesium alloy bionic cannulated screws for treatment of femoral neck fractures: a finite element analysis
BACKGROUND: Cannulated screws (CS) are one of the most widely used treatments for femoral neck fracture, however, associated with high rate of complications. In this study, we designed a new type of cannulated screws called degradable magnesium alloy bionic cannulated screws (DMBCS) and our aim was...
Autores principales: | , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8371795/ https://www.ncbi.nlm.nih.gov/pubmed/34407833 http://dx.doi.org/10.1186/s13018-021-02665-2 |
_version_ | 1783739714044428288 |
---|---|
author | Ding, Kai Yang, Weijie Zhu, Jian Cheng, Xiaodong Wang, Haicheng Hao, Du Yinuo, Song Zhu, Yanbin Zhang, Yingze Chen, Wei Zhang, Qi |
author_facet | Ding, Kai Yang, Weijie Zhu, Jian Cheng, Xiaodong Wang, Haicheng Hao, Du Yinuo, Song Zhu, Yanbin Zhang, Yingze Chen, Wei Zhang, Qi |
author_sort | Ding, Kai |
collection | PubMed |
description | BACKGROUND: Cannulated screws (CS) are one of the most widely used treatments for femoral neck fracture, however, associated with high rate of complications. In this study, we designed a new type of cannulated screws called degradable magnesium alloy bionic cannulated screws (DMBCS) and our aim was to compare the biomechanical properties of DMBCS, the traditionally used titanium alloy bionic cannulated screws (TBCS) and titanium alloy cannulated screws (TTCS). METHODS: A proximal femur model was established based on CT data of a lower extremity from a voluntary healthy man. Garden type III femoral neck fracture was constructed and fixed with DMBCS, TBCS, and TTCS, respectively. Biomechanical effect which three type of CS models have on femoral neck fracture was evaluated and compared using von Mises stress distribution and displacement. RESULTS: In the normal model, the maximum stress value of cortical bone and cancellous bone was 76.18 and 6.82 MPa, and the maximum displacement was 5.52 mm. Under 3 different fracture healing status, the stress peak value of the cortical bone and cancellous bone in the DMBCS fixation model was lower than that in the TTCS and TBCS fixation, while the maximum displacement of DMBCS fixation model was slightly higher than that of TTCS and TBCS fixation models. As the fracture heals, stress peak value of the screws and cortical bone of intact models are decreasing, while stress peak value of cancellous bone is increasing initially and then decreasing. CONCLUSIONS: The DMBCS exhibits the superior biomechanical performance than TTCS and TBCS, whose fixation model is closest to the normal model in stress distribution. DMBCS is expected to reduce the rates of post-operative complications with traditional internal fixation and provide practical guidance for the structural design of CS for clinical applications. |
format | Online Article Text |
id | pubmed-8371795 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-83717952021-08-18 Titanium alloy cannulated screws and biodegradable magnesium alloy bionic cannulated screws for treatment of femoral neck fractures: a finite element analysis Ding, Kai Yang, Weijie Zhu, Jian Cheng, Xiaodong Wang, Haicheng Hao, Du Yinuo, Song Zhu, Yanbin Zhang, Yingze Chen, Wei Zhang, Qi J Orthop Surg Res Research Article BACKGROUND: Cannulated screws (CS) are one of the most widely used treatments for femoral neck fracture, however, associated with high rate of complications. In this study, we designed a new type of cannulated screws called degradable magnesium alloy bionic cannulated screws (DMBCS) and our aim was to compare the biomechanical properties of DMBCS, the traditionally used titanium alloy bionic cannulated screws (TBCS) and titanium alloy cannulated screws (TTCS). METHODS: A proximal femur model was established based on CT data of a lower extremity from a voluntary healthy man. Garden type III femoral neck fracture was constructed and fixed with DMBCS, TBCS, and TTCS, respectively. Biomechanical effect which three type of CS models have on femoral neck fracture was evaluated and compared using von Mises stress distribution and displacement. RESULTS: In the normal model, the maximum stress value of cortical bone and cancellous bone was 76.18 and 6.82 MPa, and the maximum displacement was 5.52 mm. Under 3 different fracture healing status, the stress peak value of the cortical bone and cancellous bone in the DMBCS fixation model was lower than that in the TTCS and TBCS fixation, while the maximum displacement of DMBCS fixation model was slightly higher than that of TTCS and TBCS fixation models. As the fracture heals, stress peak value of the screws and cortical bone of intact models are decreasing, while stress peak value of cancellous bone is increasing initially and then decreasing. CONCLUSIONS: The DMBCS exhibits the superior biomechanical performance than TTCS and TBCS, whose fixation model is closest to the normal model in stress distribution. DMBCS is expected to reduce the rates of post-operative complications with traditional internal fixation and provide practical guidance for the structural design of CS for clinical applications. BioMed Central 2021-08-18 /pmc/articles/PMC8371795/ /pubmed/34407833 http://dx.doi.org/10.1186/s13018-021-02665-2 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Article Ding, Kai Yang, Weijie Zhu, Jian Cheng, Xiaodong Wang, Haicheng Hao, Du Yinuo, Song Zhu, Yanbin Zhang, Yingze Chen, Wei Zhang, Qi Titanium alloy cannulated screws and biodegradable magnesium alloy bionic cannulated screws for treatment of femoral neck fractures: a finite element analysis |
title | Titanium alloy cannulated screws and biodegradable magnesium alloy bionic cannulated screws for treatment of femoral neck fractures: a finite element analysis |
title_full | Titanium alloy cannulated screws and biodegradable magnesium alloy bionic cannulated screws for treatment of femoral neck fractures: a finite element analysis |
title_fullStr | Titanium alloy cannulated screws and biodegradable magnesium alloy bionic cannulated screws for treatment of femoral neck fractures: a finite element analysis |
title_full_unstemmed | Titanium alloy cannulated screws and biodegradable magnesium alloy bionic cannulated screws for treatment of femoral neck fractures: a finite element analysis |
title_short | Titanium alloy cannulated screws and biodegradable magnesium alloy bionic cannulated screws for treatment of femoral neck fractures: a finite element analysis |
title_sort | titanium alloy cannulated screws and biodegradable magnesium alloy bionic cannulated screws for treatment of femoral neck fractures: a finite element analysis |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8371795/ https://www.ncbi.nlm.nih.gov/pubmed/34407833 http://dx.doi.org/10.1186/s13018-021-02665-2 |
work_keys_str_mv | AT dingkai titaniumalloycannulatedscrewsandbiodegradablemagnesiumalloybioniccannulatedscrewsfortreatmentoffemoralneckfracturesafiniteelementanalysis AT yangweijie titaniumalloycannulatedscrewsandbiodegradablemagnesiumalloybioniccannulatedscrewsfortreatmentoffemoralneckfracturesafiniteelementanalysis AT zhujian titaniumalloycannulatedscrewsandbiodegradablemagnesiumalloybioniccannulatedscrewsfortreatmentoffemoralneckfracturesafiniteelementanalysis AT chengxiaodong titaniumalloycannulatedscrewsandbiodegradablemagnesiumalloybioniccannulatedscrewsfortreatmentoffemoralneckfracturesafiniteelementanalysis AT wanghaicheng titaniumalloycannulatedscrewsandbiodegradablemagnesiumalloybioniccannulatedscrewsfortreatmentoffemoralneckfracturesafiniteelementanalysis AT haodu titaniumalloycannulatedscrewsandbiodegradablemagnesiumalloybioniccannulatedscrewsfortreatmentoffemoralneckfracturesafiniteelementanalysis AT yinuosong titaniumalloycannulatedscrewsandbiodegradablemagnesiumalloybioniccannulatedscrewsfortreatmentoffemoralneckfracturesafiniteelementanalysis AT zhuyanbin titaniumalloycannulatedscrewsandbiodegradablemagnesiumalloybioniccannulatedscrewsfortreatmentoffemoralneckfracturesafiniteelementanalysis AT zhangyingze titaniumalloycannulatedscrewsandbiodegradablemagnesiumalloybioniccannulatedscrewsfortreatmentoffemoralneckfracturesafiniteelementanalysis AT chenwei titaniumalloycannulatedscrewsandbiodegradablemagnesiumalloybioniccannulatedscrewsfortreatmentoffemoralneckfracturesafiniteelementanalysis AT zhangqi titaniumalloycannulatedscrewsandbiodegradablemagnesiumalloybioniccannulatedscrewsfortreatmentoffemoralneckfracturesafiniteelementanalysis |