Cargando…

Assessing the Quality of Serological Testing in the COVID-19 Pandemic: Results of a European External Quality Assessment (EQA) Scheme for Anti-SARS-CoV-2 Antibody Detection

External quality assessment (EQA) is a key instrument for achieving harmonization, and thus a high quality, of diagnostic procedures. As reliable test results are crucial for accurate assessment of SARS-CoV-2 infection prevalence, vaccine response, and immunity, and thus for successful management of...

Descripción completa

Detalles Bibliográficos
Autores principales: Ast, Volker, Costina, Victor, Eichner, Romy, Bode, Anna, Aida, Sihem, Gerhards, Catharina, Thiaucourt, Margot, Dobler, Gerhard, Geilenkeuser, Wolf-Jochen, Wölfel, Roman, Neumaier, Michael, Haselmann, Verena
Formato: Online Artículo Texto
Lenguaje:English
Publicado: American Society for Microbiology 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8373014/
https://www.ncbi.nlm.nih.gov/pubmed/34190575
http://dx.doi.org/10.1128/JCM.00559-21
Descripción
Sumario:External quality assessment (EQA) is a key instrument for achieving harmonization, and thus a high quality, of diagnostic procedures. As reliable test results are crucial for accurate assessment of SARS-CoV-2 infection prevalence, vaccine response, and immunity, and thus for successful management of the ongoing COVID-19 pandemic, the Reference Institute for Bioanalytics (RfB) was the first EQA provider to offer an open scheme for anti-SARS-CoV-2 antibody detection. The main objectives of this EQA were (i) to gain insights into the current diagnostic landscape and the performance of serological tests in Europe and (ii) to provide recommendations for diagnostic improvements. Within the EQA, a blinded panel of precharacterized human serum samples with variable anti-SARS-CoV-2 antibody titers was provided for detection of anti-SARS-CoV-2 IgG, IgA, and IgM antibodies. Across the three distribution rounds in 2020, 284 laboratories from 22 countries reported a total of 3,744 results for anti-SARS-CoV-2 antibody detection using more than 24 different assays for IgG. Overall, 97/3,004 results were false for anti-SARS-CoV-2 IgG, 88/248 for IgA, and 34/124 for IgM. Regarding diagnostic sensitivity and specificity, substantial differences were found between the different assays used, as well as between certified and noncertified tests. For cutoff samples, a drop in the diagnostic sensitivity to 46.3% and high interlaboratory variability were observed. In general, this EQA highlights the current variability of anti-SARS-CoV-2 antibody detection, technical limitations with respect to cutoff samples, and the lack of harmonization of testing procedures. Recommendations are provided to help laboratories and manufacturers further improve the quality of anti-SARS-CoV-2 serological diagnostics.