Anatomical Phase Extraction (APE) Method: A Novel Method to Correct Detrimental Effects of Tissue-Inhomogeneity in Referenceless MR Thermometry—Preliminary Ex Vivo Investigation

PURPOSE: We present a novel background tissue phase removing method, called anatomical phase extraction (APE), and to investigate the accuracy of temperature estimation and capability of reducing background artifacts compared with the conventional referenceless methods. METHODS: Susceptibility varia...

Descripción completa

Detalles Bibliográficos
Autores principales: Huang, Chien-Feng Judith, Lin, Win-Li, Hwang, San-Chao, Yao, Ching, Chang, Hsu, Kuo, Li-Wei
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8373482/
https://www.ncbi.nlm.nih.gov/pubmed/34422091
http://dx.doi.org/10.1155/2021/5566775
_version_ 1783739950000242688
author Huang, Chien-Feng Judith
Lin, Win-Li
Hwang, San-Chao
Yao, Ching
Chang, Hsu
Kuo, Li-Wei
author_facet Huang, Chien-Feng Judith
Lin, Win-Li
Hwang, San-Chao
Yao, Ching
Chang, Hsu
Kuo, Li-Wei
author_sort Huang, Chien-Feng Judith
collection PubMed
description PURPOSE: We present a novel background tissue phase removing method, called anatomical phase extraction (APE), and to investigate the accuracy of temperature estimation and capability of reducing background artifacts compared with the conventional referenceless methods. METHODS: Susceptibility variance was acquired by subtracting pretreatment baseline images taken at different locations (nine pretreatment baselines are acquired and called φ(1) to φ(9)). The susceptibility phase data φ(S) was obtained using the Wiener deconvolution algorithm. The background phase data φ(T) was isolated by subtracting φ(S) from the whole phase data. Finally, φ(T) was subtracted from the whole phase data before applying the referenceless method. As a proof of concept, the proposed APE method was performed on ex vivo pork tenderloin and compared with other two referenceless temperature estimation approaches, including reweighted ℓ1 referenceless (RW- ℓ1) and ℓ2 referenceless methods. The proposed APE method was performed with four different baselines combination, namely, (φ(1), φ(5), φ(2), φ(4)), (φ(3), φ(5), φ(2), φ(6)), (φ(7), φ(5), φ(8), φ(4)), and (φ(9), φ(5), φ(8), φ(6)), and called APE experiment 1 to 4, respectively. The multibaseline method was used as a standard reference. The mean absolute error (MAE) and two-sample t-test analysis in temperature estimation of three regions of interest (ROI) between the multibaseline method and the other three methods, i.e., APE, RW- ℓ1, and ℓ2, were calculated and compared. RESULTS: Our results show that the mean temperature errors of the APE method-experiment 1, APE method-experiment 2, APE method-experiment 3, APE method-experiment 4, and RW- ℓ1 and ℓ2 referenceless method are 1.02°C, 1.04°C, 1.00°C, 1.00°C, 4.75°C, and 13.65°C, respectively. The MAEs of the RW- ℓ1 and ℓ2 referenceless methods were higher than that of APE method. The APE method showed no significant difference (p > 0.05), compared with the multibaseline method. CONCLUSION: The present work demonstrates the use of the APE method on referenceless MR thermometry to improve the accuracy of temperature estimation during MRI guided high-intensity focused ultrasound for ablation treatment.
format Online
Article
Text
id pubmed-8373482
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-83734822021-08-19 Anatomical Phase Extraction (APE) Method: A Novel Method to Correct Detrimental Effects of Tissue-Inhomogeneity in Referenceless MR Thermometry—Preliminary Ex Vivo Investigation Huang, Chien-Feng Judith Lin, Win-Li Hwang, San-Chao Yao, Ching Chang, Hsu Kuo, Li-Wei Comput Math Methods Med Research Article PURPOSE: We present a novel background tissue phase removing method, called anatomical phase extraction (APE), and to investigate the accuracy of temperature estimation and capability of reducing background artifacts compared with the conventional referenceless methods. METHODS: Susceptibility variance was acquired by subtracting pretreatment baseline images taken at different locations (nine pretreatment baselines are acquired and called φ(1) to φ(9)). The susceptibility phase data φ(S) was obtained using the Wiener deconvolution algorithm. The background phase data φ(T) was isolated by subtracting φ(S) from the whole phase data. Finally, φ(T) was subtracted from the whole phase data before applying the referenceless method. As a proof of concept, the proposed APE method was performed on ex vivo pork tenderloin and compared with other two referenceless temperature estimation approaches, including reweighted ℓ1 referenceless (RW- ℓ1) and ℓ2 referenceless methods. The proposed APE method was performed with four different baselines combination, namely, (φ(1), φ(5), φ(2), φ(4)), (φ(3), φ(5), φ(2), φ(6)), (φ(7), φ(5), φ(8), φ(4)), and (φ(9), φ(5), φ(8), φ(6)), and called APE experiment 1 to 4, respectively. The multibaseline method was used as a standard reference. The mean absolute error (MAE) and two-sample t-test analysis in temperature estimation of three regions of interest (ROI) between the multibaseline method and the other three methods, i.e., APE, RW- ℓ1, and ℓ2, were calculated and compared. RESULTS: Our results show that the mean temperature errors of the APE method-experiment 1, APE method-experiment 2, APE method-experiment 3, APE method-experiment 4, and RW- ℓ1 and ℓ2 referenceless method are 1.02°C, 1.04°C, 1.00°C, 1.00°C, 4.75°C, and 13.65°C, respectively. The MAEs of the RW- ℓ1 and ℓ2 referenceless methods were higher than that of APE method. The APE method showed no significant difference (p > 0.05), compared with the multibaseline method. CONCLUSION: The present work demonstrates the use of the APE method on referenceless MR thermometry to improve the accuracy of temperature estimation during MRI guided high-intensity focused ultrasound for ablation treatment. Hindawi 2021-08-10 /pmc/articles/PMC8373482/ /pubmed/34422091 http://dx.doi.org/10.1155/2021/5566775 Text en Copyright © 2021 Chien-Feng Judith Huang et al. https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Huang, Chien-Feng Judith
Lin, Win-Li
Hwang, San-Chao
Yao, Ching
Chang, Hsu
Kuo, Li-Wei
Anatomical Phase Extraction (APE) Method: A Novel Method to Correct Detrimental Effects of Tissue-Inhomogeneity in Referenceless MR Thermometry—Preliminary Ex Vivo Investigation
title Anatomical Phase Extraction (APE) Method: A Novel Method to Correct Detrimental Effects of Tissue-Inhomogeneity in Referenceless MR Thermometry—Preliminary Ex Vivo Investigation
title_full Anatomical Phase Extraction (APE) Method: A Novel Method to Correct Detrimental Effects of Tissue-Inhomogeneity in Referenceless MR Thermometry—Preliminary Ex Vivo Investigation
title_fullStr Anatomical Phase Extraction (APE) Method: A Novel Method to Correct Detrimental Effects of Tissue-Inhomogeneity in Referenceless MR Thermometry—Preliminary Ex Vivo Investigation
title_full_unstemmed Anatomical Phase Extraction (APE) Method: A Novel Method to Correct Detrimental Effects of Tissue-Inhomogeneity in Referenceless MR Thermometry—Preliminary Ex Vivo Investigation
title_short Anatomical Phase Extraction (APE) Method: A Novel Method to Correct Detrimental Effects of Tissue-Inhomogeneity in Referenceless MR Thermometry—Preliminary Ex Vivo Investigation
title_sort anatomical phase extraction (ape) method: a novel method to correct detrimental effects of tissue-inhomogeneity in referenceless mr thermometry—preliminary ex vivo investigation
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8373482/
https://www.ncbi.nlm.nih.gov/pubmed/34422091
http://dx.doi.org/10.1155/2021/5566775
work_keys_str_mv AT huangchienfengjudith anatomicalphaseextractionapemethodanovelmethodtocorrectdetrimentaleffectsoftissueinhomogeneityinreferencelessmrthermometrypreliminaryexvivoinvestigation
AT linwinli anatomicalphaseextractionapemethodanovelmethodtocorrectdetrimentaleffectsoftissueinhomogeneityinreferencelessmrthermometrypreliminaryexvivoinvestigation
AT hwangsanchao anatomicalphaseextractionapemethodanovelmethodtocorrectdetrimentaleffectsoftissueinhomogeneityinreferencelessmrthermometrypreliminaryexvivoinvestigation
AT yaoching anatomicalphaseextractionapemethodanovelmethodtocorrectdetrimentaleffectsoftissueinhomogeneityinreferencelessmrthermometrypreliminaryexvivoinvestigation
AT changhsu anatomicalphaseextractionapemethodanovelmethodtocorrectdetrimentaleffectsoftissueinhomogeneityinreferencelessmrthermometrypreliminaryexvivoinvestigation
AT kuoliwei anatomicalphaseextractionapemethodanovelmethodtocorrectdetrimentaleffectsoftissueinhomogeneityinreferencelessmrthermometrypreliminaryexvivoinvestigation