Cargando…

Impact of conduction disturbances on left ventricular mass regression and geometry change following transcatheter aortic valve replacement

Our study aimed to compare the difference of LV mass regression and remodeling in regard of conduction disturbances (CD) following transcatheter aortic valve replacement (TAVR). A prospective analysis of 152 consecutive TAVR patients was performed. 53 patients (34.9%) had CD following TAVR, includin...

Descripción completa

Detalles Bibliográficos
Autores principales: Ko, Tsung-Yu, Kao, Hsien-Li, Liu, Ying-Ju, Yeh, Chih-Fan, Huang, Ching-Chang, Chen, Ying-Hsien, Hung, Chi-Sheng, Chan, Chih-Yang, Lin, Lung-Chun, Chen, Yih-Sharng, Lin, Mao-Shin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nature Publishing Group UK 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8373860/
https://www.ncbi.nlm.nih.gov/pubmed/34408241
http://dx.doi.org/10.1038/s41598-021-96297-5
_version_ 1783739992901681152
author Ko, Tsung-Yu
Kao, Hsien-Li
Liu, Ying-Ju
Yeh, Chih-Fan
Huang, Ching-Chang
Chen, Ying-Hsien
Hung, Chi-Sheng
Chan, Chih-Yang
Lin, Lung-Chun
Chen, Yih-Sharng
Lin, Mao-Shin
author_facet Ko, Tsung-Yu
Kao, Hsien-Li
Liu, Ying-Ju
Yeh, Chih-Fan
Huang, Ching-Chang
Chen, Ying-Hsien
Hung, Chi-Sheng
Chan, Chih-Yang
Lin, Lung-Chun
Chen, Yih-Sharng
Lin, Mao-Shin
author_sort Ko, Tsung-Yu
collection PubMed
description Our study aimed to compare the difference of LV mass regression and remodeling in regard of conduction disturbances (CD) following transcatheter aortic valve replacement (TAVR). A prospective analysis of 152 consecutive TAVR patients was performed. 53 patients (34.9%) had CD following TAVR, including 30 (19.7%) permanent pacemaker implantation and 23 (15.2%) new left bundle branch block. In 123 patients with 1-year follow-up, significant improvement of LV ejection fraction (LVEF) (baseline vs 12-month: 65.1 ± 13.2 vs 68.7 ± 9.1, P = 0.017) and reduced LV end-systolic volume (LVESV) (39.8 ± 25.8 vs 34.3 ± 17.1, P = 0.011) was found in non-CD group (N = 85), but not in CD group (N = 38). Both groups had significant decrease in LV mass index (baseline vs 12-month: 148.6 ± 36.9 vs. 136.4 ± 34.7 in CD group, p = 0.023; 153.0 ± 50.5 vs. 125.6 ± 35.1 in non-CD group, p < 0.0001). In 46 patients with 3-year follow-up, only non-CD patients (N = 28) had statistically significant decrease in LV mass index (Baseline vs 36-month: 180.8 ± 58.8 vs 129.8 ± 39.1, p = 0.0001). Our study showed the improvement of LV systolic function, reduced LVESV and LV mass regression at 1 year could be observed in patients without CD after TAVR. Sustained LV mass regression within 3-year was found only in patients without CD.
format Online
Article
Text
id pubmed-8373860
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Nature Publishing Group UK
record_format MEDLINE/PubMed
spelling pubmed-83738602021-08-19 Impact of conduction disturbances on left ventricular mass regression and geometry change following transcatheter aortic valve replacement Ko, Tsung-Yu Kao, Hsien-Li Liu, Ying-Ju Yeh, Chih-Fan Huang, Ching-Chang Chen, Ying-Hsien Hung, Chi-Sheng Chan, Chih-Yang Lin, Lung-Chun Chen, Yih-Sharng Lin, Mao-Shin Sci Rep Article Our study aimed to compare the difference of LV mass regression and remodeling in regard of conduction disturbances (CD) following transcatheter aortic valve replacement (TAVR). A prospective analysis of 152 consecutive TAVR patients was performed. 53 patients (34.9%) had CD following TAVR, including 30 (19.7%) permanent pacemaker implantation and 23 (15.2%) new left bundle branch block. In 123 patients with 1-year follow-up, significant improvement of LV ejection fraction (LVEF) (baseline vs 12-month: 65.1 ± 13.2 vs 68.7 ± 9.1, P = 0.017) and reduced LV end-systolic volume (LVESV) (39.8 ± 25.8 vs 34.3 ± 17.1, P = 0.011) was found in non-CD group (N = 85), but not in CD group (N = 38). Both groups had significant decrease in LV mass index (baseline vs 12-month: 148.6 ± 36.9 vs. 136.4 ± 34.7 in CD group, p = 0.023; 153.0 ± 50.5 vs. 125.6 ± 35.1 in non-CD group, p < 0.0001). In 46 patients with 3-year follow-up, only non-CD patients (N = 28) had statistically significant decrease in LV mass index (Baseline vs 36-month: 180.8 ± 58.8 vs 129.8 ± 39.1, p = 0.0001). Our study showed the improvement of LV systolic function, reduced LVESV and LV mass regression at 1 year could be observed in patients without CD after TAVR. Sustained LV mass regression within 3-year was found only in patients without CD. Nature Publishing Group UK 2021-08-18 /pmc/articles/PMC8373860/ /pubmed/34408241 http://dx.doi.org/10.1038/s41598-021-96297-5 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Article
Ko, Tsung-Yu
Kao, Hsien-Li
Liu, Ying-Ju
Yeh, Chih-Fan
Huang, Ching-Chang
Chen, Ying-Hsien
Hung, Chi-Sheng
Chan, Chih-Yang
Lin, Lung-Chun
Chen, Yih-Sharng
Lin, Mao-Shin
Impact of conduction disturbances on left ventricular mass regression and geometry change following transcatheter aortic valve replacement
title Impact of conduction disturbances on left ventricular mass regression and geometry change following transcatheter aortic valve replacement
title_full Impact of conduction disturbances on left ventricular mass regression and geometry change following transcatheter aortic valve replacement
title_fullStr Impact of conduction disturbances on left ventricular mass regression and geometry change following transcatheter aortic valve replacement
title_full_unstemmed Impact of conduction disturbances on left ventricular mass regression and geometry change following transcatheter aortic valve replacement
title_short Impact of conduction disturbances on left ventricular mass regression and geometry change following transcatheter aortic valve replacement
title_sort impact of conduction disturbances on left ventricular mass regression and geometry change following transcatheter aortic valve replacement
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8373860/
https://www.ncbi.nlm.nih.gov/pubmed/34408241
http://dx.doi.org/10.1038/s41598-021-96297-5
work_keys_str_mv AT kotsungyu impactofconductiondisturbancesonleftventricularmassregressionandgeometrychangefollowingtranscatheteraorticvalvereplacement
AT kaohsienli impactofconductiondisturbancesonleftventricularmassregressionandgeometrychangefollowingtranscatheteraorticvalvereplacement
AT liuyingju impactofconductiondisturbancesonleftventricularmassregressionandgeometrychangefollowingtranscatheteraorticvalvereplacement
AT yehchihfan impactofconductiondisturbancesonleftventricularmassregressionandgeometrychangefollowingtranscatheteraorticvalvereplacement
AT huangchingchang impactofconductiondisturbancesonleftventricularmassregressionandgeometrychangefollowingtranscatheteraorticvalvereplacement
AT chenyinghsien impactofconductiondisturbancesonleftventricularmassregressionandgeometrychangefollowingtranscatheteraorticvalvereplacement
AT hungchisheng impactofconductiondisturbancesonleftventricularmassregressionandgeometrychangefollowingtranscatheteraorticvalvereplacement
AT chanchihyang impactofconductiondisturbancesonleftventricularmassregressionandgeometrychangefollowingtranscatheteraorticvalvereplacement
AT linlungchun impactofconductiondisturbancesonleftventricularmassregressionandgeometrychangefollowingtranscatheteraorticvalvereplacement
AT chenyihsharng impactofconductiondisturbancesonleftventricularmassregressionandgeometrychangefollowingtranscatheteraorticvalvereplacement
AT linmaoshin impactofconductiondisturbancesonleftventricularmassregressionandgeometrychangefollowingtranscatheteraorticvalvereplacement