Cargando…
VISTO: An open-source device to measure exposure time in psychological experiments
The study of higher cognitive processes often relies on the manipulation of bottom-up stimulus characteristics such as exposure time. While several software exist that can schedule the onset and offset time of a visual stimulus, the actual exposure time depends on several factors that are not easy t...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8374506/ https://www.ncbi.nlm.nih.gov/pubmed/34430322 http://dx.doi.org/10.1016/j.mex.2021.101427 |
_version_ | 1783740130746433536 |
---|---|
author | De Cesarei, Andrea Marzocchi, Michele Loftus, Geoffrey R. |
author_facet | De Cesarei, Andrea Marzocchi, Michele Loftus, Geoffrey R. |
author_sort | De Cesarei, Andrea |
collection | PubMed |
description | The study of higher cognitive processes often relies on the manipulation of bottom-up stimulus characteristics such as exposure time. While several software exist that can schedule the onset and offset time of a visual stimulus, the actual exposure time depends on several factors that are not easy to control, resulting in undesired variability within and across studies. Here we present VISTO, a simple device built on the Arduino platform that allows one to measure the exact onset and offset of a visual stimulus, and to test its synchronization with a trigger signal. The device is used to measure the profile of luminance waveforms in arbitrary analog/digital (AD) units, and the implications of these luminance profiles are discussed based on a model of information accumulation from visual exposure. Moreover, VISTO can be calibrated to match the brightness of each experimental monitor. VISTO allows for control of stimulus timing presentation, both in classical laboratory settings and in more complex settings as technology allows to use new display devices or acquisition equipment. In sum, VISTO allows one to: • measure the profile of luminance curves. • determine the exposure time of a visual stimulus. • measure the synchronization between a trigger signal and a visual stimulus. |
format | Online Article Text |
id | pubmed-8374506 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-83745062021-08-23 VISTO: An open-source device to measure exposure time in psychological experiments De Cesarei, Andrea Marzocchi, Michele Loftus, Geoffrey R. MethodsX Method Article The study of higher cognitive processes often relies on the manipulation of bottom-up stimulus characteristics such as exposure time. While several software exist that can schedule the onset and offset time of a visual stimulus, the actual exposure time depends on several factors that are not easy to control, resulting in undesired variability within and across studies. Here we present VISTO, a simple device built on the Arduino platform that allows one to measure the exact onset and offset of a visual stimulus, and to test its synchronization with a trigger signal. The device is used to measure the profile of luminance waveforms in arbitrary analog/digital (AD) units, and the implications of these luminance profiles are discussed based on a model of information accumulation from visual exposure. Moreover, VISTO can be calibrated to match the brightness of each experimental monitor. VISTO allows for control of stimulus timing presentation, both in classical laboratory settings and in more complex settings as technology allows to use new display devices or acquisition equipment. In sum, VISTO allows one to: • measure the profile of luminance curves. • determine the exposure time of a visual stimulus. • measure the synchronization between a trigger signal and a visual stimulus. Elsevier 2021-06-22 /pmc/articles/PMC8374506/ /pubmed/34430322 http://dx.doi.org/10.1016/j.mex.2021.101427 Text en © 2021 The Authors. Published by Elsevier B.V. https://creativecommons.org/licenses/by/4.0/This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Method Article De Cesarei, Andrea Marzocchi, Michele Loftus, Geoffrey R. VISTO: An open-source device to measure exposure time in psychological experiments |
title | VISTO: An open-source device to measure exposure time in psychological experiments |
title_full | VISTO: An open-source device to measure exposure time in psychological experiments |
title_fullStr | VISTO: An open-source device to measure exposure time in psychological experiments |
title_full_unstemmed | VISTO: An open-source device to measure exposure time in psychological experiments |
title_short | VISTO: An open-source device to measure exposure time in psychological experiments |
title_sort | visto: an open-source device to measure exposure time in psychological experiments |
topic | Method Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8374506/ https://www.ncbi.nlm.nih.gov/pubmed/34430322 http://dx.doi.org/10.1016/j.mex.2021.101427 |
work_keys_str_mv | AT decesareiandrea vistoanopensourcedevicetomeasureexposuretimeinpsychologicalexperiments AT marzocchimichele vistoanopensourcedevicetomeasureexposuretimeinpsychologicalexperiments AT loftusgeoffreyr vistoanopensourcedevicetomeasureexposuretimeinpsychologicalexperiments |