Cargando…

VISTO: An open-source device to measure exposure time in psychological experiments

The study of higher cognitive processes often relies on the manipulation of bottom-up stimulus characteristics such as exposure time. While several software exist that can schedule the onset and offset time of a visual stimulus, the actual exposure time depends on several factors that are not easy t...

Descripción completa

Detalles Bibliográficos
Autores principales: De Cesarei, Andrea, Marzocchi, Michele, Loftus, Geoffrey R.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8374506/
https://www.ncbi.nlm.nih.gov/pubmed/34430322
http://dx.doi.org/10.1016/j.mex.2021.101427
_version_ 1783740130746433536
author De Cesarei, Andrea
Marzocchi, Michele
Loftus, Geoffrey R.
author_facet De Cesarei, Andrea
Marzocchi, Michele
Loftus, Geoffrey R.
author_sort De Cesarei, Andrea
collection PubMed
description The study of higher cognitive processes often relies on the manipulation of bottom-up stimulus characteristics such as exposure time. While several software exist that can schedule the onset and offset time of a visual stimulus, the actual exposure time depends on several factors that are not easy to control, resulting in undesired variability within and across studies. Here we present VISTO, a simple device built on the Arduino platform that allows one to measure the exact onset and offset of a visual stimulus, and to test its synchronization with a trigger signal. The device is used to measure the profile of luminance waveforms in arbitrary analog/digital (AD) units, and the implications of these luminance profiles are discussed based on a model of information accumulation from visual exposure. Moreover, VISTO can be calibrated to match the brightness of each experimental monitor. VISTO allows for control of stimulus timing presentation, both in classical laboratory settings and in more complex settings as technology allows to use new display devices or acquisition equipment. In sum, VISTO allows one to: • measure the profile of luminance curves. • determine the exposure time of a visual stimulus. • measure the synchronization between a trigger signal and a visual stimulus.
format Online
Article
Text
id pubmed-8374506
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-83745062021-08-23 VISTO: An open-source device to measure exposure time in psychological experiments De Cesarei, Andrea Marzocchi, Michele Loftus, Geoffrey R. MethodsX Method Article The study of higher cognitive processes often relies on the manipulation of bottom-up stimulus characteristics such as exposure time. While several software exist that can schedule the onset and offset time of a visual stimulus, the actual exposure time depends on several factors that are not easy to control, resulting in undesired variability within and across studies. Here we present VISTO, a simple device built on the Arduino platform that allows one to measure the exact onset and offset of a visual stimulus, and to test its synchronization with a trigger signal. The device is used to measure the profile of luminance waveforms in arbitrary analog/digital (AD) units, and the implications of these luminance profiles are discussed based on a model of information accumulation from visual exposure. Moreover, VISTO can be calibrated to match the brightness of each experimental monitor. VISTO allows for control of stimulus timing presentation, both in classical laboratory settings and in more complex settings as technology allows to use new display devices or acquisition equipment. In sum, VISTO allows one to: • measure the profile of luminance curves. • determine the exposure time of a visual stimulus. • measure the synchronization between a trigger signal and a visual stimulus. Elsevier 2021-06-22 /pmc/articles/PMC8374506/ /pubmed/34430322 http://dx.doi.org/10.1016/j.mex.2021.101427 Text en © 2021 The Authors. Published by Elsevier B.V. https://creativecommons.org/licenses/by/4.0/This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Method Article
De Cesarei, Andrea
Marzocchi, Michele
Loftus, Geoffrey R.
VISTO: An open-source device to measure exposure time in psychological experiments
title VISTO: An open-source device to measure exposure time in psychological experiments
title_full VISTO: An open-source device to measure exposure time in psychological experiments
title_fullStr VISTO: An open-source device to measure exposure time in psychological experiments
title_full_unstemmed VISTO: An open-source device to measure exposure time in psychological experiments
title_short VISTO: An open-source device to measure exposure time in psychological experiments
title_sort visto: an open-source device to measure exposure time in psychological experiments
topic Method Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8374506/
https://www.ncbi.nlm.nih.gov/pubmed/34430322
http://dx.doi.org/10.1016/j.mex.2021.101427
work_keys_str_mv AT decesareiandrea vistoanopensourcedevicetomeasureexposuretimeinpsychologicalexperiments
AT marzocchimichele vistoanopensourcedevicetomeasureexposuretimeinpsychologicalexperiments
AT loftusgeoffreyr vistoanopensourcedevicetomeasureexposuretimeinpsychologicalexperiments