Cargando…

Assessing the results of anophthalmic prostheses

PURPOSE: Anophthalmic sockets cause disfigurement that may result in emotional and social distress. The choice of procedure and implant is based upon the surgeon’s experience. There remains no standardization of cosmetic result. We sought to identify quantifiable anatomical features and functional p...

Descripción completa

Detalles Bibliográficos
Autores principales: Vardizer, Yoav, Sobeh, Tamer, Prat, Daphna Landau, Ben Simon, Guy J, Tomkins-Netzer, Oren
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer - Medknow 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8374791/
https://www.ncbi.nlm.nih.gov/pubmed/34146048
http://dx.doi.org/10.4103/ijo.IJO_2682_20
Descripción
Sumario:PURPOSE: Anophthalmic sockets cause disfigurement that may result in emotional and social distress. The choice of procedure and implant is based upon the surgeon’s experience. There remains no standardization of cosmetic result. We sought to identify quantifiable anatomical features and functional properties related to a successful cosmetic result in patients with ocular prosthesis and to determine correlations between self-reported and third-party assessment of cosmetic success. METHODS: This was a prospective observational study, which included 107 adult patients (50.1% female; age 53.08 ± 18.64 years, range 18–89) with acquired anophthalmia following prosthesis fitting. Patients completed a self-assessment questionnaire on self-perception of body image and ocular properties. Three independent examiners assessed cosmetic score. Assessed variables included prosthesis movement, eyelid symmetry, prosthesis stability, and socket fullness. RESULTS: The general cosmetic result was 8.1 ± 2.19 (on a predetermined scale of 1–10) as perceived by the patients and 7.2 ± 0.19 by the examiners. Interexaminer correlation was high for all variables (P < 0.05). A good cosmetic result was correlated with prosthesis movement (P = 0.02), eyelid symmetry (P = 0.001), and prosthesis stability (P = 0.01). Factors that correlated with a good cosmetic result on multivariate analysis were prosthesis movement (odds ratio [OR] 4.95, P = 0.004), eyelid symmetry (OR 4.51, P = 0.006), and socket fullness (OR 3.56, P = 0.005). No correlation was observed between patients’ perceptions of the overall cosmetic result and those of the examiners. CONCLUSION: The cosmetic result of prosthesis use among anophthalmic patients is generally good, as perceived by both patients and examiners. Good eyelid position and symmetry, orbital fullness, and prosthesis motility were associated with a better cosmetic result.