Cargando…

Automated iris volume analysis and trabecular meshwork length using anterior segment optical coherence tomography - Application in pseudoexfoliation and pseudoexfoliation glaucoma

PURPOSE: The aim of this study was to evaluate differences in the iris and angle parameters in psuedoexfoliation syndrome (PXF) and pseudoexfoliation glaucoma (PXG) using anterior segment optical coherence tomography (ASOCT). METHODS: Patients with PXF or PXG were compared using ASOCT with primary o...

Descripción completa

Detalles Bibliográficos
Autores principales: Rao, Aparna, Vupparaboina, Kiran Kumar, Padhy, Debananda, Raj, Niranjan, Pradhan, Amiya, Goud, Abilash, Peguda, Hari Kumar, Jana, Soumya, Richariya, Ashutosh
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer - Medknow 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8374829/
https://www.ncbi.nlm.nih.gov/pubmed/34146036
http://dx.doi.org/10.4103/ijo.IJO_2403_20
_version_ 1783740199971323904
author Rao, Aparna
Vupparaboina, Kiran Kumar
Padhy, Debananda
Raj, Niranjan
Pradhan, Amiya
Goud, Abilash
Peguda, Hari Kumar
Jana, Soumya
Richariya, Ashutosh
author_facet Rao, Aparna
Vupparaboina, Kiran Kumar
Padhy, Debananda
Raj, Niranjan
Pradhan, Amiya
Goud, Abilash
Peguda, Hari Kumar
Jana, Soumya
Richariya, Ashutosh
author_sort Rao, Aparna
collection PubMed
description PURPOSE: The aim of this study was to evaluate differences in the iris and angle parameters in psuedoexfoliation syndrome (PXF) and pseudoexfoliation glaucoma (PXG) using anterior segment optical coherence tomography (ASOCT). METHODS: Patients with PXF or PXG were compared using ASOCT with primary open-angle glaucoma POAG eyes as controls in this noninterventional comparative study conducted at a tertiary eye care center in East India. All angle parameters, TM length, and iris thickness were analyzed from the enhanced depth imaging (EDI) single scans obtained. Quadrant scans were used for the calculation of iris volume using a custom-built in-house software. In particular, the software performs multiple operations including edge detection, connected components, and thresholding to localize and segment the iris. Differences in the iris volume/thickness and TM length in PXF and PXG with POAG were analyzed. RESULTS: A total of 225 eyes were included, which included 75 PXG and 98 PXF cases and 52 POAG with a mean age of 67 ± 9.7 years at presentation. The algorithm repeatability and reproducibility was also established with correlation coefficients more than 99% which was substantiated with Bland-Altman plots. The iris volume (calculated in 197 images of 225 eyes) did not differ significantly in PXF and PXG eyes, although both had significantly greater volume compared to POAG eyes. The iris volume or other angle parameters including TM length did not correlate with clinical variables such as IOP, age, or visual field indices. CONCLUSION: Iris parameters or TM length do not explain pathogenesis of glaucoma in pseudoexfoliation.
format Online
Article
Text
id pubmed-8374829
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Wolters Kluwer - Medknow
record_format MEDLINE/PubMed
spelling pubmed-83748292021-08-25 Automated iris volume analysis and trabecular meshwork length using anterior segment optical coherence tomography - Application in pseudoexfoliation and pseudoexfoliation glaucoma Rao, Aparna Vupparaboina, Kiran Kumar Padhy, Debananda Raj, Niranjan Pradhan, Amiya Goud, Abilash Peguda, Hari Kumar Jana, Soumya Richariya, Ashutosh Indian J Ophthalmol Original Article PURPOSE: The aim of this study was to evaluate differences in the iris and angle parameters in psuedoexfoliation syndrome (PXF) and pseudoexfoliation glaucoma (PXG) using anterior segment optical coherence tomography (ASOCT). METHODS: Patients with PXF or PXG were compared using ASOCT with primary open-angle glaucoma POAG eyes as controls in this noninterventional comparative study conducted at a tertiary eye care center in East India. All angle parameters, TM length, and iris thickness were analyzed from the enhanced depth imaging (EDI) single scans obtained. Quadrant scans were used for the calculation of iris volume using a custom-built in-house software. In particular, the software performs multiple operations including edge detection, connected components, and thresholding to localize and segment the iris. Differences in the iris volume/thickness and TM length in PXF and PXG with POAG were analyzed. RESULTS: A total of 225 eyes were included, which included 75 PXG and 98 PXF cases and 52 POAG with a mean age of 67 ± 9.7 years at presentation. The algorithm repeatability and reproducibility was also established with correlation coefficients more than 99% which was substantiated with Bland-Altman plots. The iris volume (calculated in 197 images of 225 eyes) did not differ significantly in PXF and PXG eyes, although both had significantly greater volume compared to POAG eyes. The iris volume or other angle parameters including TM length did not correlate with clinical variables such as IOP, age, or visual field indices. CONCLUSION: Iris parameters or TM length do not explain pathogenesis of glaucoma in pseudoexfoliation. Wolters Kluwer - Medknow 2021-07 2021-06-18 /pmc/articles/PMC8374829/ /pubmed/34146036 http://dx.doi.org/10.4103/ijo.IJO_2403_20 Text en Copyright: © 2021 Indian Journal of Ophthalmology https://creativecommons.org/licenses/by-nc-sa/4.0/This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
spellingShingle Original Article
Rao, Aparna
Vupparaboina, Kiran Kumar
Padhy, Debananda
Raj, Niranjan
Pradhan, Amiya
Goud, Abilash
Peguda, Hari Kumar
Jana, Soumya
Richariya, Ashutosh
Automated iris volume analysis and trabecular meshwork length using anterior segment optical coherence tomography - Application in pseudoexfoliation and pseudoexfoliation glaucoma
title Automated iris volume analysis and trabecular meshwork length using anterior segment optical coherence tomography - Application in pseudoexfoliation and pseudoexfoliation glaucoma
title_full Automated iris volume analysis and trabecular meshwork length using anterior segment optical coherence tomography - Application in pseudoexfoliation and pseudoexfoliation glaucoma
title_fullStr Automated iris volume analysis and trabecular meshwork length using anterior segment optical coherence tomography - Application in pseudoexfoliation and pseudoexfoliation glaucoma
title_full_unstemmed Automated iris volume analysis and trabecular meshwork length using anterior segment optical coherence tomography - Application in pseudoexfoliation and pseudoexfoliation glaucoma
title_short Automated iris volume analysis and trabecular meshwork length using anterior segment optical coherence tomography - Application in pseudoexfoliation and pseudoexfoliation glaucoma
title_sort automated iris volume analysis and trabecular meshwork length using anterior segment optical coherence tomography - application in pseudoexfoliation and pseudoexfoliation glaucoma
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8374829/
https://www.ncbi.nlm.nih.gov/pubmed/34146036
http://dx.doi.org/10.4103/ijo.IJO_2403_20
work_keys_str_mv AT raoaparna automatedirisvolumeanalysisandtrabecularmeshworklengthusinganteriorsegmentopticalcoherencetomographyapplicationinpseudoexfoliationandpseudoexfoliationglaucoma
AT vupparaboinakirankumar automatedirisvolumeanalysisandtrabecularmeshworklengthusinganteriorsegmentopticalcoherencetomographyapplicationinpseudoexfoliationandpseudoexfoliationglaucoma
AT padhydebananda automatedirisvolumeanalysisandtrabecularmeshworklengthusinganteriorsegmentopticalcoherencetomographyapplicationinpseudoexfoliationandpseudoexfoliationglaucoma
AT rajniranjan automatedirisvolumeanalysisandtrabecularmeshworklengthusinganteriorsegmentopticalcoherencetomographyapplicationinpseudoexfoliationandpseudoexfoliationglaucoma
AT pradhanamiya automatedirisvolumeanalysisandtrabecularmeshworklengthusinganteriorsegmentopticalcoherencetomographyapplicationinpseudoexfoliationandpseudoexfoliationglaucoma
AT goudabilash automatedirisvolumeanalysisandtrabecularmeshworklengthusinganteriorsegmentopticalcoherencetomographyapplicationinpseudoexfoliationandpseudoexfoliationglaucoma
AT pegudaharikumar automatedirisvolumeanalysisandtrabecularmeshworklengthusinganteriorsegmentopticalcoherencetomographyapplicationinpseudoexfoliationandpseudoexfoliationglaucoma
AT janasoumya automatedirisvolumeanalysisandtrabecularmeshworklengthusinganteriorsegmentopticalcoherencetomographyapplicationinpseudoexfoliationandpseudoexfoliationglaucoma
AT richariyaashutosh automatedirisvolumeanalysisandtrabecularmeshworklengthusinganteriorsegmentopticalcoherencetomographyapplicationinpseudoexfoliationandpseudoexfoliationglaucoma