Cargando…
Reliability in Standardization of Iron(III) and Titanium(III) Solutions in Volumetric Analysis
[Image: see text] Titanium(III) is a useful strong reductant and is usually standardized with iron(III) in volumetric analysis. Iron(III) is widely used as an oxidant and is usually standardized with thiosulfate ions through an iodine liberation reaction. The evaluation of the standardization proced...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
American Chemical Society
2021
|
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8375104/ https://www.ncbi.nlm.nih.gov/pubmed/34423222 http://dx.doi.org/10.1021/acsomega.1c03074 |
_version_ | 1783740253428776960 |
---|---|
author | Asakai, Toshiaki Suzuki, Toshihiro |
author_facet | Asakai, Toshiaki Suzuki, Toshihiro |
author_sort | Asakai, Toshiaki |
collection | PubMed |
description | [Image: see text] Titanium(III) is a useful strong reductant and is usually standardized with iron(III) in volumetric analysis. Iron(III) is widely used as an oxidant and is usually standardized with thiosulfate ions through an iodine liberation reaction. The evaluation of the standardization procedure for iron(III) with thiosulfate ions is therefore essential to ensure the reliability of standardized titanium(III) solutions. To investigate the titration procedure for iron(III), two different titrations were performed: redox titration with thiosulfate ions through an iodine liberation reaction and chelatometric titration with disodium dihydrogen ethylenediaminetetraacetate. Subsequently, for the investigation of standardization of iron(III), titanium(III) was assayed through two titration paths: redox titration with standardized iron(III) and redox titration with standard potassium dichromate. The reliability of titrimetric procedures was evaluated by applying several different stoichiometric reactions to each chemical. All titrimetric procedures were consistent with each other within their expanded uncertainties and were capable of providing reliable volumetric standards with careful operations presented in this study. |
format | Online Article Text |
id | pubmed-8375104 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | American Chemical Society |
record_format | MEDLINE/PubMed |
spelling | pubmed-83751042021-08-20 Reliability in Standardization of Iron(III) and Titanium(III) Solutions in Volumetric Analysis Asakai, Toshiaki Suzuki, Toshihiro ACS Omega [Image: see text] Titanium(III) is a useful strong reductant and is usually standardized with iron(III) in volumetric analysis. Iron(III) is widely used as an oxidant and is usually standardized with thiosulfate ions through an iodine liberation reaction. The evaluation of the standardization procedure for iron(III) with thiosulfate ions is therefore essential to ensure the reliability of standardized titanium(III) solutions. To investigate the titration procedure for iron(III), two different titrations were performed: redox titration with thiosulfate ions through an iodine liberation reaction and chelatometric titration with disodium dihydrogen ethylenediaminetetraacetate. Subsequently, for the investigation of standardization of iron(III), titanium(III) was assayed through two titration paths: redox titration with standardized iron(III) and redox titration with standard potassium dichromate. The reliability of titrimetric procedures was evaluated by applying several different stoichiometric reactions to each chemical. All titrimetric procedures were consistent with each other within their expanded uncertainties and were capable of providing reliable volumetric standards with careful operations presented in this study. American Chemical Society 2021-08-05 /pmc/articles/PMC8375104/ /pubmed/34423222 http://dx.doi.org/10.1021/acsomega.1c03074 Text en © 2021 The Authors. Published by American Chemical Society https://creativecommons.org/licenses/by/4.0/Permits the broadest form of re-use including for commercial purposes, provided that author attribution and integrity are maintained (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Asakai, Toshiaki Suzuki, Toshihiro Reliability in Standardization of Iron(III) and Titanium(III) Solutions in Volumetric Analysis |
title | Reliability in Standardization of Iron(III) and Titanium(III)
Solutions in Volumetric Analysis |
title_full | Reliability in Standardization of Iron(III) and Titanium(III)
Solutions in Volumetric Analysis |
title_fullStr | Reliability in Standardization of Iron(III) and Titanium(III)
Solutions in Volumetric Analysis |
title_full_unstemmed | Reliability in Standardization of Iron(III) and Titanium(III)
Solutions in Volumetric Analysis |
title_short | Reliability in Standardization of Iron(III) and Titanium(III)
Solutions in Volumetric Analysis |
title_sort | reliability in standardization of iron(iii) and titanium(iii)
solutions in volumetric analysis |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8375104/ https://www.ncbi.nlm.nih.gov/pubmed/34423222 http://dx.doi.org/10.1021/acsomega.1c03074 |
work_keys_str_mv | AT asakaitoshiaki reliabilityinstandardizationofironiiiandtitaniumiiisolutionsinvolumetricanalysis AT suzukitoshihiro reliabilityinstandardizationofironiiiandtitaniumiiisolutionsinvolumetricanalysis |