Cargando…

Comparative Evaluation of Internal Margin Adaptation and Integrity of Class I Preparations using Two Composites: An In Vitro Study

AIM AND OBJECTIVES: The aim of this study is to evaluate the internal margin adaptation and integrity of Class 1 preparations using two composites types (bulk fill/conventional) with two placement methods (4/2 mm increments). MATERIALS AND METHODS: Class 1 preparations of 4 mm × 4 mm dimensions were...

Descripción completa

Detalles Bibliográficos
Autores principales: Bhol, Subhasmita, Patwa, Neha, Sharan, Suprabha, Sha, Shemil Mohamed, Abdul, Muqthadir Siddiqui Mohammed, Pius, Alen, Singh, Shalini
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer - Medknow 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8375881/
https://www.ncbi.nlm.nih.gov/pubmed/34447107
http://dx.doi.org/10.4103/jpbs.JPBS_739_20
_version_ 1783740388237901824
author Bhol, Subhasmita
Patwa, Neha
Sharan, Suprabha
Sha, Shemil Mohamed
Abdul, Muqthadir Siddiqui Mohammed
Pius, Alen
Singh, Shalini
author_facet Bhol, Subhasmita
Patwa, Neha
Sharan, Suprabha
Sha, Shemil Mohamed
Abdul, Muqthadir Siddiqui Mohammed
Pius, Alen
Singh, Shalini
author_sort Bhol, Subhasmita
collection PubMed
description AIM AND OBJECTIVES: The aim of this study is to evaluate the internal margin adaptation and integrity of Class 1 preparations using two composites types (bulk fill/conventional) with two placement methods (4/2 mm increments). MATERIALS AND METHODS: Class 1 preparations of 4 mm × 4 mm dimensions were made on 30 extracted human mandibular molars. They were randomly divided into three groups; among them, in Group 1 (n = 10), cavities were filled with SureFil SDR Bulk Fill, Group 2 (n = 10) cavities were filled with Filtek Bulk Fill of 4 mm increments in both groups, and in Group 3 (n = 10), cavities were filled with conventional composite Filtek Z350 with 2 mm increments. Samples were sectioned occlusogingivally. Then, dye was on internal margins, and images of each specimen were recorded using a digital camera to evaluate the marginal integrity and adaptation of restorative material to the tooth surface with image analysis software. Then, collected data were put under the statistical analysis with analysis of variance test and post hoc Tukey's test. RESULTS: There was no significant difference in overall dye penetration in bulk fill and conventional (incremental fill) composite resins; however, when dye penetration was evaluated at different locations, within enamel and mid-dentin, significantly more gap-free margins were found than at the pulpal interface. Filtek Bulk Fill and conventional composite (Filtek Z350) showed comparatively more dye penetration toward the pulpal interface compared to SDR Bulk Fill. CONCLUSION: There were no significant differences in percentage of gap-free margins between fill types for any of the composite materials. The proportions of gap-free margin were less at the pulpal interface and mid-dentin portions and enamel when filled with 4 and 2 mm increments.
format Online
Article
Text
id pubmed-8375881
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Wolters Kluwer - Medknow
record_format MEDLINE/PubMed
spelling pubmed-83758812021-08-25 Comparative Evaluation of Internal Margin Adaptation and Integrity of Class I Preparations using Two Composites: An In Vitro Study Bhol, Subhasmita Patwa, Neha Sharan, Suprabha Sha, Shemil Mohamed Abdul, Muqthadir Siddiqui Mohammed Pius, Alen Singh, Shalini J Pharm Bioallied Sci Original Article AIM AND OBJECTIVES: The aim of this study is to evaluate the internal margin adaptation and integrity of Class 1 preparations using two composites types (bulk fill/conventional) with two placement methods (4/2 mm increments). MATERIALS AND METHODS: Class 1 preparations of 4 mm × 4 mm dimensions were made on 30 extracted human mandibular molars. They were randomly divided into three groups; among them, in Group 1 (n = 10), cavities were filled with SureFil SDR Bulk Fill, Group 2 (n = 10) cavities were filled with Filtek Bulk Fill of 4 mm increments in both groups, and in Group 3 (n = 10), cavities were filled with conventional composite Filtek Z350 with 2 mm increments. Samples were sectioned occlusogingivally. Then, dye was on internal margins, and images of each specimen were recorded using a digital camera to evaluate the marginal integrity and adaptation of restorative material to the tooth surface with image analysis software. Then, collected data were put under the statistical analysis with analysis of variance test and post hoc Tukey's test. RESULTS: There was no significant difference in overall dye penetration in bulk fill and conventional (incremental fill) composite resins; however, when dye penetration was evaluated at different locations, within enamel and mid-dentin, significantly more gap-free margins were found than at the pulpal interface. Filtek Bulk Fill and conventional composite (Filtek Z350) showed comparatively more dye penetration toward the pulpal interface compared to SDR Bulk Fill. CONCLUSION: There were no significant differences in percentage of gap-free margins between fill types for any of the composite materials. The proportions of gap-free margin were less at the pulpal interface and mid-dentin portions and enamel when filled with 4 and 2 mm increments. Wolters Kluwer - Medknow 2021-06 2021-06-05 /pmc/articles/PMC8375881/ /pubmed/34447107 http://dx.doi.org/10.4103/jpbs.JPBS_739_20 Text en Copyright: © 2021 Journal of Pharmacy and Bioallied Sciences https://creativecommons.org/licenses/by-nc-sa/4.0/This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
spellingShingle Original Article
Bhol, Subhasmita
Patwa, Neha
Sharan, Suprabha
Sha, Shemil Mohamed
Abdul, Muqthadir Siddiqui Mohammed
Pius, Alen
Singh, Shalini
Comparative Evaluation of Internal Margin Adaptation and Integrity of Class I Preparations using Two Composites: An In Vitro Study
title Comparative Evaluation of Internal Margin Adaptation and Integrity of Class I Preparations using Two Composites: An In Vitro Study
title_full Comparative Evaluation of Internal Margin Adaptation and Integrity of Class I Preparations using Two Composites: An In Vitro Study
title_fullStr Comparative Evaluation of Internal Margin Adaptation and Integrity of Class I Preparations using Two Composites: An In Vitro Study
title_full_unstemmed Comparative Evaluation of Internal Margin Adaptation and Integrity of Class I Preparations using Two Composites: An In Vitro Study
title_short Comparative Evaluation of Internal Margin Adaptation and Integrity of Class I Preparations using Two Composites: An In Vitro Study
title_sort comparative evaluation of internal margin adaptation and integrity of class i preparations using two composites: an in vitro study
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8375881/
https://www.ncbi.nlm.nih.gov/pubmed/34447107
http://dx.doi.org/10.4103/jpbs.JPBS_739_20
work_keys_str_mv AT bholsubhasmita comparativeevaluationofinternalmarginadaptationandintegrityofclassipreparationsusingtwocompositesaninvitrostudy
AT patwaneha comparativeevaluationofinternalmarginadaptationandintegrityofclassipreparationsusingtwocompositesaninvitrostudy
AT sharansuprabha comparativeevaluationofinternalmarginadaptationandintegrityofclassipreparationsusingtwocompositesaninvitrostudy
AT shashemilmohamed comparativeevaluationofinternalmarginadaptationandintegrityofclassipreparationsusingtwocompositesaninvitrostudy
AT abdulmuqthadirsiddiquimohammed comparativeevaluationofinternalmarginadaptationandintegrityofclassipreparationsusingtwocompositesaninvitrostudy
AT piusalen comparativeevaluationofinternalmarginadaptationandintegrityofclassipreparationsusingtwocompositesaninvitrostudy
AT singhshalini comparativeevaluationofinternalmarginadaptationandintegrityofclassipreparationsusingtwocompositesaninvitrostudy