Cargando…

Cone-Beam Computed Tomography Assessment of Canal-Centering Ability for Traditionally Used Nickel Titanium and Nickel Titanium Files with Reciprocating Hand Piece and Wave-One Files

AIM OF THE STUDY: Need for our study was to evaluate a comparison between canal preparation ability of nickel–titanium (NiTi) hand files with step-back manual technique, of NiTi files installed on a reciprocating hand piece and of Wave-One files utilizing noninvasive cone-beam computed tomography (C...

Descripción completa

Detalles Bibliográficos
Autores principales: Shaik, Rubeena Tabasum, Uppalapati, Satyanarayana V. V., Uppu, Lavanya Neelima, Sudhamsetty, Sriramarao, Kumar, D. Praneeth, Kumpatla, Maheswari
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer - Medknow 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8375924/
https://www.ncbi.nlm.nih.gov/pubmed/34447050
http://dx.doi.org/10.4103/jpbs.JPBS_568_20
_version_ 1783740398406991872
author Shaik, Rubeena Tabasum
Uppalapati, Satyanarayana V. V.
Uppu, Lavanya Neelima
Sudhamsetty, Sriramarao
Kumar, D. Praneeth
Kumpatla, Maheswari
author_facet Shaik, Rubeena Tabasum
Uppalapati, Satyanarayana V. V.
Uppu, Lavanya Neelima
Sudhamsetty, Sriramarao
Kumar, D. Praneeth
Kumpatla, Maheswari
author_sort Shaik, Rubeena Tabasum
collection PubMed
description AIM OF THE STUDY: Need for our study was to evaluate a comparison between canal preparation ability of nickel–titanium (NiTi) hand files with step-back manual technique, of NiTi files installed on a reciprocating hand piece and of Wave-One files utilizing noninvasive cone-beam computed tomography (CBCT) technique. MATERIALS AND METHODS: Thirty extracted intact single-rooted human mandibular premolars were used in the study, segregated in three sets of 10 specimens each, where canal instrumentation was done by different methods using NiTi in step-back technique, using reciprocating hand piece with NiTi files and using primary file with the use of Wave-One reciprocating system. Later, evaluation of centering ability was conducted using the references through CBCT images. RESULTS: Hand NiTi files showed even less canal centering ability as compared to other two sets. Mesiodistal diameter at 9 mm length of the prepared canal was 1.06 and later was 0.98, which shows excessive preparation in case of Set I versus Set II. In case of comparison between Set III and Set I, mesiodistal diameter at 9 mm length of the prepared canal was 0.99, and later was 1.06, depicting better canal shaping ability with Wave-One file. CONCLUSION: The use of hand NiTi files installed on a reciprocating hand piece would be economically beneficial producing the similar results as that of wave one without any deviation from the original canal anatomy.
format Online
Article
Text
id pubmed-8375924
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Wolters Kluwer - Medknow
record_format MEDLINE/PubMed
spelling pubmed-83759242021-08-25 Cone-Beam Computed Tomography Assessment of Canal-Centering Ability for Traditionally Used Nickel Titanium and Nickel Titanium Files with Reciprocating Hand Piece and Wave-One Files Shaik, Rubeena Tabasum Uppalapati, Satyanarayana V. V. Uppu, Lavanya Neelima Sudhamsetty, Sriramarao Kumar, D. Praneeth Kumpatla, Maheswari J Pharm Bioallied Sci Original Article AIM OF THE STUDY: Need for our study was to evaluate a comparison between canal preparation ability of nickel–titanium (NiTi) hand files with step-back manual technique, of NiTi files installed on a reciprocating hand piece and of Wave-One files utilizing noninvasive cone-beam computed tomography (CBCT) technique. MATERIALS AND METHODS: Thirty extracted intact single-rooted human mandibular premolars were used in the study, segregated in three sets of 10 specimens each, where canal instrumentation was done by different methods using NiTi in step-back technique, using reciprocating hand piece with NiTi files and using primary file with the use of Wave-One reciprocating system. Later, evaluation of centering ability was conducted using the references through CBCT images. RESULTS: Hand NiTi files showed even less canal centering ability as compared to other two sets. Mesiodistal diameter at 9 mm length of the prepared canal was 1.06 and later was 0.98, which shows excessive preparation in case of Set I versus Set II. In case of comparison between Set III and Set I, mesiodistal diameter at 9 mm length of the prepared canal was 0.99, and later was 1.06, depicting better canal shaping ability with Wave-One file. CONCLUSION: The use of hand NiTi files installed on a reciprocating hand piece would be economically beneficial producing the similar results as that of wave one without any deviation from the original canal anatomy. Wolters Kluwer - Medknow 2021-06 2021-06-05 /pmc/articles/PMC8375924/ /pubmed/34447050 http://dx.doi.org/10.4103/jpbs.JPBS_568_20 Text en Copyright: © 2021 Journal of Pharmacy and Bioallied Sciences https://creativecommons.org/licenses/by-nc-sa/4.0/This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
spellingShingle Original Article
Shaik, Rubeena Tabasum
Uppalapati, Satyanarayana V. V.
Uppu, Lavanya Neelima
Sudhamsetty, Sriramarao
Kumar, D. Praneeth
Kumpatla, Maheswari
Cone-Beam Computed Tomography Assessment of Canal-Centering Ability for Traditionally Used Nickel Titanium and Nickel Titanium Files with Reciprocating Hand Piece and Wave-One Files
title Cone-Beam Computed Tomography Assessment of Canal-Centering Ability for Traditionally Used Nickel Titanium and Nickel Titanium Files with Reciprocating Hand Piece and Wave-One Files
title_full Cone-Beam Computed Tomography Assessment of Canal-Centering Ability for Traditionally Used Nickel Titanium and Nickel Titanium Files with Reciprocating Hand Piece and Wave-One Files
title_fullStr Cone-Beam Computed Tomography Assessment of Canal-Centering Ability for Traditionally Used Nickel Titanium and Nickel Titanium Files with Reciprocating Hand Piece and Wave-One Files
title_full_unstemmed Cone-Beam Computed Tomography Assessment of Canal-Centering Ability for Traditionally Used Nickel Titanium and Nickel Titanium Files with Reciprocating Hand Piece and Wave-One Files
title_short Cone-Beam Computed Tomography Assessment of Canal-Centering Ability for Traditionally Used Nickel Titanium and Nickel Titanium Files with Reciprocating Hand Piece and Wave-One Files
title_sort cone-beam computed tomography assessment of canal-centering ability for traditionally used nickel titanium and nickel titanium files with reciprocating hand piece and wave-one files
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8375924/
https://www.ncbi.nlm.nih.gov/pubmed/34447050
http://dx.doi.org/10.4103/jpbs.JPBS_568_20
work_keys_str_mv AT shaikrubeenatabasum conebeamcomputedtomographyassessmentofcanalcenteringabilityfortraditionallyusednickeltitaniumandnickeltitaniumfileswithreciprocatinghandpieceandwaveonefiles
AT uppalapatisatyanarayanavv conebeamcomputedtomographyassessmentofcanalcenteringabilityfortraditionallyusednickeltitaniumandnickeltitaniumfileswithreciprocatinghandpieceandwaveonefiles
AT uppulavanyaneelima conebeamcomputedtomographyassessmentofcanalcenteringabilityfortraditionallyusednickeltitaniumandnickeltitaniumfileswithreciprocatinghandpieceandwaveonefiles
AT sudhamsettysriramarao conebeamcomputedtomographyassessmentofcanalcenteringabilityfortraditionallyusednickeltitaniumandnickeltitaniumfileswithreciprocatinghandpieceandwaveonefiles
AT kumardpraneeth conebeamcomputedtomographyassessmentofcanalcenteringabilityfortraditionallyusednickeltitaniumandnickeltitaniumfileswithreciprocatinghandpieceandwaveonefiles
AT kumpatlamaheswari conebeamcomputedtomographyassessmentofcanalcenteringabilityfortraditionallyusednickeltitaniumandnickeltitaniumfileswithreciprocatinghandpieceandwaveonefiles