Cargando…

Efficiency of Different Endodontic Irrigation and Activation Systems, Self-Adjusting File Instrumentation/Irrigation System, and XP-Endo Finisher in Removal of the Intracanal Smear Layer: An Ex vivo Scanning Electron Microscope Study

AIM: This ex vivo study was designed to evaluate and compare different endodontic irrigation and activation systems, the self-adjusting file (SAF) instrumentation/irrigation system, and XP-endo finisher for removal of intracanal smear layer. MATERIALS AND METHODS: Fifty recently extracted, noncariou...

Descripción completa

Detalles Bibliográficos
Autores principales: Karade, Priyatam, Sharma, Deepak, Hoshing, Upendra A., Medha, Ashish H., Bhagat, Anil R., Chopade, Rutuja V.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer - Medknow 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8375950/
https://www.ncbi.nlm.nih.gov/pubmed/34447120
http://dx.doi.org/10.4103/jpbs.JPBS_775_20
_version_ 1783740404623998976
author Karade, Priyatam
Sharma, Deepak
Hoshing, Upendra A.
Medha, Ashish H.
Bhagat, Anil R.
Chopade, Rutuja V.
author_facet Karade, Priyatam
Sharma, Deepak
Hoshing, Upendra A.
Medha, Ashish H.
Bhagat, Anil R.
Chopade, Rutuja V.
author_sort Karade, Priyatam
collection PubMed
description AIM: This ex vivo study was designed to evaluate and compare different endodontic irrigation and activation systems, the self-adjusting file (SAF) instrumentation/irrigation system, and XP-endo finisher for removal of intracanal smear layer. MATERIALS AND METHODS: Fifty recently extracted, noncarious human intact single-rooted premolars were selected and divided into five groups (n = 10) according to the root canal irrigation systems; syringe and needle irrigation, passive ultrasonic irrigation (PUI), EndoVac irrigation system, SAF system, and XP-endo finisher. All groups were prepared to apical size F4 file except for the SAF group which was prepared to apical size 20 K-file and then instrumented with the SAF file. Each sample was subjected to final irrigation using different irrigation/activation systems. After splitting the samples, one half of each root was selected for examination under scanning electron microscope. The irrigation systems were compared using the Fisher's exact test with significance set at P < 0.05. RESULTS: In the coronal part, there was no difference among the groups. In the mid-root section, the results of the PUI, EndoVac, SAF, and XP-endo finisher groups tended to be better than syringe and needle irrigation, but the difference was not significant. The apical part of the canal, the SAF system, and XP-endo finisher group seemed to be cleaner than those of the EndoVac group, but this difference was not significant. CONCLUSIONS: Within the limitations of the present study, SAF system and XP-endo finisher group cleaned the apical part of the canal more efficiently than EndoVac, PUI, and syringe and needle irrigation.
format Online
Article
Text
id pubmed-8375950
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Wolters Kluwer - Medknow
record_format MEDLINE/PubMed
spelling pubmed-83759502021-08-25 Efficiency of Different Endodontic Irrigation and Activation Systems, Self-Adjusting File Instrumentation/Irrigation System, and XP-Endo Finisher in Removal of the Intracanal Smear Layer: An Ex vivo Scanning Electron Microscope Study Karade, Priyatam Sharma, Deepak Hoshing, Upendra A. Medha, Ashish H. Bhagat, Anil R. Chopade, Rutuja V. J Pharm Bioallied Sci Original Article AIM: This ex vivo study was designed to evaluate and compare different endodontic irrigation and activation systems, the self-adjusting file (SAF) instrumentation/irrigation system, and XP-endo finisher for removal of intracanal smear layer. MATERIALS AND METHODS: Fifty recently extracted, noncarious human intact single-rooted premolars were selected and divided into five groups (n = 10) according to the root canal irrigation systems; syringe and needle irrigation, passive ultrasonic irrigation (PUI), EndoVac irrigation system, SAF system, and XP-endo finisher. All groups were prepared to apical size F4 file except for the SAF group which was prepared to apical size 20 K-file and then instrumented with the SAF file. Each sample was subjected to final irrigation using different irrigation/activation systems. After splitting the samples, one half of each root was selected for examination under scanning electron microscope. The irrigation systems were compared using the Fisher's exact test with significance set at P < 0.05. RESULTS: In the coronal part, there was no difference among the groups. In the mid-root section, the results of the PUI, EndoVac, SAF, and XP-endo finisher groups tended to be better than syringe and needle irrigation, but the difference was not significant. The apical part of the canal, the SAF system, and XP-endo finisher group seemed to be cleaner than those of the EndoVac group, but this difference was not significant. CONCLUSIONS: Within the limitations of the present study, SAF system and XP-endo finisher group cleaned the apical part of the canal more efficiently than EndoVac, PUI, and syringe and needle irrigation. Wolters Kluwer - Medknow 2021-06 2021-06-05 /pmc/articles/PMC8375950/ /pubmed/34447120 http://dx.doi.org/10.4103/jpbs.JPBS_775_20 Text en Copyright: © 2021 Journal of Pharmacy and Bioallied Sciences https://creativecommons.org/licenses/by-nc-sa/4.0/This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
spellingShingle Original Article
Karade, Priyatam
Sharma, Deepak
Hoshing, Upendra A.
Medha, Ashish H.
Bhagat, Anil R.
Chopade, Rutuja V.
Efficiency of Different Endodontic Irrigation and Activation Systems, Self-Adjusting File Instrumentation/Irrigation System, and XP-Endo Finisher in Removal of the Intracanal Smear Layer: An Ex vivo Scanning Electron Microscope Study
title Efficiency of Different Endodontic Irrigation and Activation Systems, Self-Adjusting File Instrumentation/Irrigation System, and XP-Endo Finisher in Removal of the Intracanal Smear Layer: An Ex vivo Scanning Electron Microscope Study
title_full Efficiency of Different Endodontic Irrigation and Activation Systems, Self-Adjusting File Instrumentation/Irrigation System, and XP-Endo Finisher in Removal of the Intracanal Smear Layer: An Ex vivo Scanning Electron Microscope Study
title_fullStr Efficiency of Different Endodontic Irrigation and Activation Systems, Self-Adjusting File Instrumentation/Irrigation System, and XP-Endo Finisher in Removal of the Intracanal Smear Layer: An Ex vivo Scanning Electron Microscope Study
title_full_unstemmed Efficiency of Different Endodontic Irrigation and Activation Systems, Self-Adjusting File Instrumentation/Irrigation System, and XP-Endo Finisher in Removal of the Intracanal Smear Layer: An Ex vivo Scanning Electron Microscope Study
title_short Efficiency of Different Endodontic Irrigation and Activation Systems, Self-Adjusting File Instrumentation/Irrigation System, and XP-Endo Finisher in Removal of the Intracanal Smear Layer: An Ex vivo Scanning Electron Microscope Study
title_sort efficiency of different endodontic irrigation and activation systems, self-adjusting file instrumentation/irrigation system, and xp-endo finisher in removal of the intracanal smear layer: an ex vivo scanning electron microscope study
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8375950/
https://www.ncbi.nlm.nih.gov/pubmed/34447120
http://dx.doi.org/10.4103/jpbs.JPBS_775_20
work_keys_str_mv AT karadepriyatam efficiencyofdifferentendodonticirrigationandactivationsystemsselfadjustingfileinstrumentationirrigationsystemandxpendofinisherinremovaloftheintracanalsmearlayeranexvivoscanningelectronmicroscopestudy
AT sharmadeepak efficiencyofdifferentendodonticirrigationandactivationsystemsselfadjustingfileinstrumentationirrigationsystemandxpendofinisherinremovaloftheintracanalsmearlayeranexvivoscanningelectronmicroscopestudy
AT hoshingupendraa efficiencyofdifferentendodonticirrigationandactivationsystemsselfadjustingfileinstrumentationirrigationsystemandxpendofinisherinremovaloftheintracanalsmearlayeranexvivoscanningelectronmicroscopestudy
AT medhaashishh efficiencyofdifferentendodonticirrigationandactivationsystemsselfadjustingfileinstrumentationirrigationsystemandxpendofinisherinremovaloftheintracanalsmearlayeranexvivoscanningelectronmicroscopestudy
AT bhagatanilr efficiencyofdifferentendodonticirrigationandactivationsystemsselfadjustingfileinstrumentationirrigationsystemandxpendofinisherinremovaloftheintracanalsmearlayeranexvivoscanningelectronmicroscopestudy
AT chopaderutujav efficiencyofdifferentendodonticirrigationandactivationsystemsselfadjustingfileinstrumentationirrigationsystemandxpendofinisherinremovaloftheintracanalsmearlayeranexvivoscanningelectronmicroscopestudy