Analysis of Surface Roughness and Three-dimensional Scanning Topography of Zirconia Implants before and after Photofunctionalization by Atomic Force Microscopy: An In Vitro Study
AIM: To analyze surface roughness and three-dimensional (3D) scanning topography parameters of zirconia implants before and after photofunctionalization by atomic force microscopy (AFM). MATERIALS AND METHODS: Ten commercially available zirconia implants five each in the study and control group were...
Autores principales: | Jaikumar, R. Arun, Karthigeyan, Suma, Ramesh Bhat, T.R, Naidu, Madhulika, Praveen Raj, G. R., Natarajan, Senthil |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Wolters Kluwer - Medknow
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8375956/ https://www.ncbi.nlm.nih.gov/pubmed/34447198 http://dx.doi.org/10.4103/jpbs.JPBS_724_20 |
Ejemplares similares
-
Analysis of Surface Morphology and Elemental Composition on Zirconia Implants Before and After Photofunctionalization by Scanning Electron Microscopy and Energy Dispersive X ray Spectroscopy – An In vitro Study
por: Jaikumar, R. Arun, et al.
Publicado: (2021) -
Surface Modification Techniques for Zirconia-Based Bioceramics: A Review
por: Karthigeyan, Suma, et al.
Publicado: (2019) -
Comparison of flexural strength in three types of denture base resins: An in vitro study
por: Jaikumar, R. Arun, et al.
Publicado: (2015) -
TiO(2) Coating and UV Photofunctionalization Enhance Blood Coagulation on Zirconia Surfaces
por: Shahramian, Khalil, et al.
Publicado: (2019) -
An In-Vitro Analysis of Peri-Implant Mucosal Seal Following Photofunctionalization of Zirconia Abutment Materials
por: Razali, Masfueh, et al.
Publicado: (2021)