Cargando…

Evaluation of the distance from the anterior cervicovaginal junction to the anterior peritoneal reflection for anterior colpotomy during vaginal hysterectomy in Korean women

This study aimed to know the distance of the cervicovaginal junction (CVJ) to the anterior peritoneal reflection (APR) as measured in surgical specimens, and assess the distance between the CVJ and APR to ensure safe anterior colpotomy for vaginal hysterectomy among Korean women. Patients who underw...

Descripción completa

Detalles Bibliográficos
Autores principales: Lee, Ji Hye, Chae, Su Hyun, Lee, A. Jin, Min, Yoon Jung, So, Kyeong A., Lee, Sun Joo, Kim, Tae Jin, Shim, Seung-Hyuk
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Lippincott Williams & Wilkins 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8376323/
https://www.ncbi.nlm.nih.gov/pubmed/34414953
http://dx.doi.org/10.1097/MD.0000000000026941
_version_ 1783740470281633792
author Lee, Ji Hye
Chae, Su Hyun
Lee, A. Jin
Min, Yoon Jung
So, Kyeong A.
Lee, Sun Joo
Kim, Tae Jin
Shim, Seung-Hyuk
author_facet Lee, Ji Hye
Chae, Su Hyun
Lee, A. Jin
Min, Yoon Jung
So, Kyeong A.
Lee, Sun Joo
Kim, Tae Jin
Shim, Seung-Hyuk
author_sort Lee, Ji Hye
collection PubMed
description This study aimed to know the distance of the cervicovaginal junction (CVJ) to the anterior peritoneal reflection (APR) as measured in surgical specimens, and assess the distance between the CVJ and APR to ensure safe anterior colpotomy for vaginal hysterectomy among Korean women. Patients who underwent vaginal hysterectomy were included in the analysis. According to the presence of pelvic organ prolapse or menopausal status, the distance from the CVJ to the APR was assessed preoperatively through transvaginal ultrasonography (TV-US), as well as intraoperatively using surgical specimens. The intraclass correlation coefficient was used to determine the reliability between 2 measurements. In total, 171 patients were included. The median distance from the CVJ to the APR measured on TV-US was 19.8 (3.3–41.3) mm. Meanwhile, the median distance from the CVJ to the APR measured using the surgical specimen was 26.0 (12.0–55.0) mm. The intraclass correlation coefficient for the absolute agreement between 2 measurements was 0.353 (95% confidence interval: 0.002–0.570; P < .001), which is indicative of poor reliability. The median distance from the CVJ to the APR measured using the surgical specimen did not differ significantly between the 2 groups according to pelvic organ prolapse (26.0 [12.0–55.0] vs 27.5 [17.0–55.0] mm, P = .076] and menopausal status (27.0 [15.0–55.0] vs 26.0 [12.0–55.0] mm, P = .237). TV-US does not an accurately measure the dissection plane length from the CVJ to the APR during anterior colpotomy. During vaginal hysterectomy, the median distance from the CVJ to the APR measured using the surgical specimen was 26 (12.0–55.0) mm, which can help decrease surgical complications.
format Online
Article
Text
id pubmed-8376323
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Lippincott Williams & Wilkins
record_format MEDLINE/PubMed
spelling pubmed-83763232021-08-21 Evaluation of the distance from the anterior cervicovaginal junction to the anterior peritoneal reflection for anterior colpotomy during vaginal hysterectomy in Korean women Lee, Ji Hye Chae, Su Hyun Lee, A. Jin Min, Yoon Jung So, Kyeong A. Lee, Sun Joo Kim, Tae Jin Shim, Seung-Hyuk Medicine (Baltimore) 5600 This study aimed to know the distance of the cervicovaginal junction (CVJ) to the anterior peritoneal reflection (APR) as measured in surgical specimens, and assess the distance between the CVJ and APR to ensure safe anterior colpotomy for vaginal hysterectomy among Korean women. Patients who underwent vaginal hysterectomy were included in the analysis. According to the presence of pelvic organ prolapse or menopausal status, the distance from the CVJ to the APR was assessed preoperatively through transvaginal ultrasonography (TV-US), as well as intraoperatively using surgical specimens. The intraclass correlation coefficient was used to determine the reliability between 2 measurements. In total, 171 patients were included. The median distance from the CVJ to the APR measured on TV-US was 19.8 (3.3–41.3) mm. Meanwhile, the median distance from the CVJ to the APR measured using the surgical specimen was 26.0 (12.0–55.0) mm. The intraclass correlation coefficient for the absolute agreement between 2 measurements was 0.353 (95% confidence interval: 0.002–0.570; P < .001), which is indicative of poor reliability. The median distance from the CVJ to the APR measured using the surgical specimen did not differ significantly between the 2 groups according to pelvic organ prolapse (26.0 [12.0–55.0] vs 27.5 [17.0–55.0] mm, P = .076] and menopausal status (27.0 [15.0–55.0] vs 26.0 [12.0–55.0] mm, P = .237). TV-US does not an accurately measure the dissection plane length from the CVJ to the APR during anterior colpotomy. During vaginal hysterectomy, the median distance from the CVJ to the APR measured using the surgical specimen was 26 (12.0–55.0) mm, which can help decrease surgical complications. Lippincott Williams & Wilkins 2021-08-20 /pmc/articles/PMC8376323/ /pubmed/34414953 http://dx.doi.org/10.1097/MD.0000000000026941 Text en Copyright © 2021 the Author(s). Published by Wolters Kluwer Health, Inc. https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the Creative Commons Attribution License 4.0 (CCBY), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. http://creativecommons.org/licenses/by/4.0 (https://creativecommons.org/licenses/by/4.0/)
spellingShingle 5600
Lee, Ji Hye
Chae, Su Hyun
Lee, A. Jin
Min, Yoon Jung
So, Kyeong A.
Lee, Sun Joo
Kim, Tae Jin
Shim, Seung-Hyuk
Evaluation of the distance from the anterior cervicovaginal junction to the anterior peritoneal reflection for anterior colpotomy during vaginal hysterectomy in Korean women
title Evaluation of the distance from the anterior cervicovaginal junction to the anterior peritoneal reflection for anterior colpotomy during vaginal hysterectomy in Korean women
title_full Evaluation of the distance from the anterior cervicovaginal junction to the anterior peritoneal reflection for anterior colpotomy during vaginal hysterectomy in Korean women
title_fullStr Evaluation of the distance from the anterior cervicovaginal junction to the anterior peritoneal reflection for anterior colpotomy during vaginal hysterectomy in Korean women
title_full_unstemmed Evaluation of the distance from the anterior cervicovaginal junction to the anterior peritoneal reflection for anterior colpotomy during vaginal hysterectomy in Korean women
title_short Evaluation of the distance from the anterior cervicovaginal junction to the anterior peritoneal reflection for anterior colpotomy during vaginal hysterectomy in Korean women
title_sort evaluation of the distance from the anterior cervicovaginal junction to the anterior peritoneal reflection for anterior colpotomy during vaginal hysterectomy in korean women
topic 5600
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8376323/
https://www.ncbi.nlm.nih.gov/pubmed/34414953
http://dx.doi.org/10.1097/MD.0000000000026941
work_keys_str_mv AT leejihye evaluationofthedistancefromtheanteriorcervicovaginaljunctiontotheanteriorperitonealreflectionforanteriorcolpotomyduringvaginalhysterectomyinkoreanwomen
AT chaesuhyun evaluationofthedistancefromtheanteriorcervicovaginaljunctiontotheanteriorperitonealreflectionforanteriorcolpotomyduringvaginalhysterectomyinkoreanwomen
AT leeajin evaluationofthedistancefromtheanteriorcervicovaginaljunctiontotheanteriorperitonealreflectionforanteriorcolpotomyduringvaginalhysterectomyinkoreanwomen
AT minyoonjung evaluationofthedistancefromtheanteriorcervicovaginaljunctiontotheanteriorperitonealreflectionforanteriorcolpotomyduringvaginalhysterectomyinkoreanwomen
AT sokyeonga evaluationofthedistancefromtheanteriorcervicovaginaljunctiontotheanteriorperitonealreflectionforanteriorcolpotomyduringvaginalhysterectomyinkoreanwomen
AT leesunjoo evaluationofthedistancefromtheanteriorcervicovaginaljunctiontotheanteriorperitonealreflectionforanteriorcolpotomyduringvaginalhysterectomyinkoreanwomen
AT kimtaejin evaluationofthedistancefromtheanteriorcervicovaginaljunctiontotheanteriorperitonealreflectionforanteriorcolpotomyduringvaginalhysterectomyinkoreanwomen
AT shimseunghyuk evaluationofthedistancefromtheanteriorcervicovaginaljunctiontotheanteriorperitonealreflectionforanteriorcolpotomyduringvaginalhysterectomyinkoreanwomen