Cargando…

Accuracy of Thoracolumbar Pedicle Screw Insertion Based on Routine Use of Intraoperative Imaging and Navigation

STUDY DESIGN: Retrospective review. PURPOSE: To determine the accuracy of thoracolumbar pedicle screw insertion with the routine use of three-dimensional (3D) intraoperative imaging and navigation over a large series of screws in an Asian population. OVERVIEW OF LITERATURE: The use of 3D intraoperat...

Descripción completa

Detalles Bibliográficos
Autores principales: Sundaram, Pirateb Paramasivam Meenakshi, Oh, Jacob Yoong-Leong, Tan, Mark, Nolan, Colum Patrick, Yu, Chun Sing, Ling, Ji Min
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Korean Society of Spine Surgery 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8377205/
https://www.ncbi.nlm.nih.gov/pubmed/32951407
http://dx.doi.org/10.31616/asj.2020.0068
_version_ 1783740608913866752
author Sundaram, Pirateb Paramasivam Meenakshi
Oh, Jacob Yoong-Leong
Tan, Mark
Nolan, Colum Patrick
Yu, Chun Sing
Ling, Ji Min
author_facet Sundaram, Pirateb Paramasivam Meenakshi
Oh, Jacob Yoong-Leong
Tan, Mark
Nolan, Colum Patrick
Yu, Chun Sing
Ling, Ji Min
author_sort Sundaram, Pirateb Paramasivam Meenakshi
collection PubMed
description STUDY DESIGN: Retrospective review. PURPOSE: To determine the accuracy of thoracolumbar pedicle screw insertion with the routine use of three-dimensional (3D) intraoperative imaging and navigation over a large series of screws in an Asian population. OVERVIEW OF LITERATURE: The use of 3D intraoperative imaging and navigation in spinal surgery is aimed at improving the accuracy of pedicle screw insertion. This study analyzed 2,240 pedicle screws inserted with the routine use of intraoperative navigation. It is one of very few studies done on an Asian population with a large series of screws. METHODS: Patients who had undergone thoracolumbar pedicle screws insertion using intraoperative imaging and navigation between 2009 and 2017 were retrospectively analyzed. Computed tomography (CT) images acquired after the insertion of pedicle screws were analyzed for breach of the pedicle wall. The pedicle screw breaches were graded according to the Gertzbein classification. The breach rate and revision rate were subsequently calculated. RESULTS: A total of 2,240 thoracolumbar pedicle screws inserted under the guidance of intraoperative navigation were analyzed, and the accuracy of the insertion was 97.41%. The overall breach rate was 2.59%, the major breach rate was 0.94%, and the intraoperative screw revision rate was 0.7%. There was no incidence of return to the operating theater for revision of screws. CONCLUSIONS: The routine use of 3D navigation and intraoperative CT imaging resulted in consistently accurate pedicle screw placement. This improved the safety of spinal instrumentation and helped in avoiding revision surgery for malpositioned screws.
format Online
Article
Text
id pubmed-8377205
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Korean Society of Spine Surgery
record_format MEDLINE/PubMed
spelling pubmed-83772052021-08-25 Accuracy of Thoracolumbar Pedicle Screw Insertion Based on Routine Use of Intraoperative Imaging and Navigation Sundaram, Pirateb Paramasivam Meenakshi Oh, Jacob Yoong-Leong Tan, Mark Nolan, Colum Patrick Yu, Chun Sing Ling, Ji Min Asian Spine J Clinical Study STUDY DESIGN: Retrospective review. PURPOSE: To determine the accuracy of thoracolumbar pedicle screw insertion with the routine use of three-dimensional (3D) intraoperative imaging and navigation over a large series of screws in an Asian population. OVERVIEW OF LITERATURE: The use of 3D intraoperative imaging and navigation in spinal surgery is aimed at improving the accuracy of pedicle screw insertion. This study analyzed 2,240 pedicle screws inserted with the routine use of intraoperative navigation. It is one of very few studies done on an Asian population with a large series of screws. METHODS: Patients who had undergone thoracolumbar pedicle screws insertion using intraoperative imaging and navigation between 2009 and 2017 were retrospectively analyzed. Computed tomography (CT) images acquired after the insertion of pedicle screws were analyzed for breach of the pedicle wall. The pedicle screw breaches were graded according to the Gertzbein classification. The breach rate and revision rate were subsequently calculated. RESULTS: A total of 2,240 thoracolumbar pedicle screws inserted under the guidance of intraoperative navigation were analyzed, and the accuracy of the insertion was 97.41%. The overall breach rate was 2.59%, the major breach rate was 0.94%, and the intraoperative screw revision rate was 0.7%. There was no incidence of return to the operating theater for revision of screws. CONCLUSIONS: The routine use of 3D navigation and intraoperative CT imaging resulted in consistently accurate pedicle screw placement. This improved the safety of spinal instrumentation and helped in avoiding revision surgery for malpositioned screws. Korean Society of Spine Surgery 2021-08 2020-09-22 /pmc/articles/PMC8377205/ /pubmed/32951407 http://dx.doi.org/10.31616/asj.2020.0068 Text en Copyright © 2021 by Korean Society of Spine Surgery https://creativecommons.org/licenses/by-nc/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/ (https://creativecommons.org/licenses/by-nc/4.0/) ) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Clinical Study
Sundaram, Pirateb Paramasivam Meenakshi
Oh, Jacob Yoong-Leong
Tan, Mark
Nolan, Colum Patrick
Yu, Chun Sing
Ling, Ji Min
Accuracy of Thoracolumbar Pedicle Screw Insertion Based on Routine Use of Intraoperative Imaging and Navigation
title Accuracy of Thoracolumbar Pedicle Screw Insertion Based on Routine Use of Intraoperative Imaging and Navigation
title_full Accuracy of Thoracolumbar Pedicle Screw Insertion Based on Routine Use of Intraoperative Imaging and Navigation
title_fullStr Accuracy of Thoracolumbar Pedicle Screw Insertion Based on Routine Use of Intraoperative Imaging and Navigation
title_full_unstemmed Accuracy of Thoracolumbar Pedicle Screw Insertion Based on Routine Use of Intraoperative Imaging and Navigation
title_short Accuracy of Thoracolumbar Pedicle Screw Insertion Based on Routine Use of Intraoperative Imaging and Navigation
title_sort accuracy of thoracolumbar pedicle screw insertion based on routine use of intraoperative imaging and navigation
topic Clinical Study
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8377205/
https://www.ncbi.nlm.nih.gov/pubmed/32951407
http://dx.doi.org/10.31616/asj.2020.0068
work_keys_str_mv AT sundarampiratebparamasivammeenakshi accuracyofthoracolumbarpediclescrewinsertionbasedonroutineuseofintraoperativeimagingandnavigation
AT ohjacobyoongleong accuracyofthoracolumbarpediclescrewinsertionbasedonroutineuseofintraoperativeimagingandnavigation
AT tanmark accuracyofthoracolumbarpediclescrewinsertionbasedonroutineuseofintraoperativeimagingandnavigation
AT nolancolumpatrick accuracyofthoracolumbarpediclescrewinsertionbasedonroutineuseofintraoperativeimagingandnavigation
AT yuchunsing accuracyofthoracolumbarpediclescrewinsertionbasedonroutineuseofintraoperativeimagingandnavigation
AT lingjimin accuracyofthoracolumbarpediclescrewinsertionbasedonroutineuseofintraoperativeimagingandnavigation