Cargando…
The accuracy of extended-spectrum beta-lactamase detection in Escherichia coli and Klebsiella pneumoniae in South African laboratories using the Vitek 2 Gram-negative susceptibility card AST-N255
BACKGROUND: Phenotypic detection of extended-spectrum beta-lactamases (ESBLs) is based on the inhibition of ESBL enzymes by β-lactamase inhibitors and on the comparison of cephalosporin activity with or without a β-lactamase inhibitor. Many South African diagnostic laboratories rely on the Vitek 2 f...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
AOSIS
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8378085/ https://www.ncbi.nlm.nih.gov/pubmed/34485454 http://dx.doi.org/10.4102/sajid.v34i1.114 |
_version_ | 1783740768090849280 |
---|---|
author | Young, Andrea L. Nicol, Mark P. Moodley, Clinton Bamford, Colleen M. |
author_facet | Young, Andrea L. Nicol, Mark P. Moodley, Clinton Bamford, Colleen M. |
author_sort | Young, Andrea L. |
collection | PubMed |
description | BACKGROUND: Phenotypic detection of extended-spectrum beta-lactamases (ESBLs) is based on the inhibition of ESBL enzymes by β-lactamase inhibitors and on the comparison of cephalosporin activity with or without a β-lactamase inhibitor. Many South African diagnostic laboratories rely on the Vitek 2 for automated susceptibility testing and for ESBL detection. However, the Gram-negative susceptibility card currently used locally (AST-N255) has been modified and its accuracy for ESBL detection is not known. METHODS: We randomly selected 50 isolates of Klebsiella pneumoniae and Escherichia coli from a collection of clinical bloodstream isolates from Groote Schuur Hospital from 2015 to 2016, including ESBL-producing and non-ESBL-producing strains. We used standardised phenotypic (disc diffusion and broth microdilution) and genotypic (conventional polymerase chain reaction (PCR) for bla(CTX-M), bla(SHV) and bla(TEM)) methods for detection of ESBLs. We compared ESBL detection by Vitek 2 to a composite reference standard comprising ESBL detection either by both phenotypic methods or by one phenotypic method together with genotypic detection. RESULTS: The sensitivity of Vitek 2 system for detection of ESBLs was 33/36 or 92% (78% – 97%) for E. coli, and 40/40 or 100% (91% – 100%) for K. pneumoniae, whilst specificity was 10/10 or 100% (72% – 100%) and 9/10 or 90% (60% – 98%), respectively. This is comparable with previous studies. CONCLUSION: Using a composite reference standard of the phenotypic and genotypic methods employed in this study, no Vitek-categorised ESBL E. coli or K. pneumoniae was found to be a non-ESBL with the exception of possible misinterpretation with K. pneumoniae SHV-hyper-producing isolates. |
format | Online Article Text |
id | pubmed-8378085 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | AOSIS |
record_format | MEDLINE/PubMed |
spelling | pubmed-83780852021-09-03 The accuracy of extended-spectrum beta-lactamase detection in Escherichia coli and Klebsiella pneumoniae in South African laboratories using the Vitek 2 Gram-negative susceptibility card AST-N255 Young, Andrea L. Nicol, Mark P. Moodley, Clinton Bamford, Colleen M. S Afr J Infect Dis Original Research BACKGROUND: Phenotypic detection of extended-spectrum beta-lactamases (ESBLs) is based on the inhibition of ESBL enzymes by β-lactamase inhibitors and on the comparison of cephalosporin activity with or without a β-lactamase inhibitor. Many South African diagnostic laboratories rely on the Vitek 2 for automated susceptibility testing and for ESBL detection. However, the Gram-negative susceptibility card currently used locally (AST-N255) has been modified and its accuracy for ESBL detection is not known. METHODS: We randomly selected 50 isolates of Klebsiella pneumoniae and Escherichia coli from a collection of clinical bloodstream isolates from Groote Schuur Hospital from 2015 to 2016, including ESBL-producing and non-ESBL-producing strains. We used standardised phenotypic (disc diffusion and broth microdilution) and genotypic (conventional polymerase chain reaction (PCR) for bla(CTX-M), bla(SHV) and bla(TEM)) methods for detection of ESBLs. We compared ESBL detection by Vitek 2 to a composite reference standard comprising ESBL detection either by both phenotypic methods or by one phenotypic method together with genotypic detection. RESULTS: The sensitivity of Vitek 2 system for detection of ESBLs was 33/36 or 92% (78% – 97%) for E. coli, and 40/40 or 100% (91% – 100%) for K. pneumoniae, whilst specificity was 10/10 or 100% (72% – 100%) and 9/10 or 90% (60% – 98%), respectively. This is comparable with previous studies. CONCLUSION: Using a composite reference standard of the phenotypic and genotypic methods employed in this study, no Vitek-categorised ESBL E. coli or K. pneumoniae was found to be a non-ESBL with the exception of possible misinterpretation with K. pneumoniae SHV-hyper-producing isolates. AOSIS 2019-08-07 /pmc/articles/PMC8378085/ /pubmed/34485454 http://dx.doi.org/10.4102/sajid.v34i1.114 Text en © 2019. The Authors https://creativecommons.org/licenses/by/4.0/Licensee: AOSIS. This work is licensed under the Creative Commons Attribution License. |
spellingShingle | Original Research Young, Andrea L. Nicol, Mark P. Moodley, Clinton Bamford, Colleen M. The accuracy of extended-spectrum beta-lactamase detection in Escherichia coli and Klebsiella pneumoniae in South African laboratories using the Vitek 2 Gram-negative susceptibility card AST-N255 |
title | The accuracy of extended-spectrum beta-lactamase detection in Escherichia coli and Klebsiella pneumoniae in South African laboratories using the Vitek 2 Gram-negative susceptibility card AST-N255 |
title_full | The accuracy of extended-spectrum beta-lactamase detection in Escherichia coli and Klebsiella pneumoniae in South African laboratories using the Vitek 2 Gram-negative susceptibility card AST-N255 |
title_fullStr | The accuracy of extended-spectrum beta-lactamase detection in Escherichia coli and Klebsiella pneumoniae in South African laboratories using the Vitek 2 Gram-negative susceptibility card AST-N255 |
title_full_unstemmed | The accuracy of extended-spectrum beta-lactamase detection in Escherichia coli and Klebsiella pneumoniae in South African laboratories using the Vitek 2 Gram-negative susceptibility card AST-N255 |
title_short | The accuracy of extended-spectrum beta-lactamase detection in Escherichia coli and Klebsiella pneumoniae in South African laboratories using the Vitek 2 Gram-negative susceptibility card AST-N255 |
title_sort | accuracy of extended-spectrum beta-lactamase detection in escherichia coli and klebsiella pneumoniae in south african laboratories using the vitek 2 gram-negative susceptibility card ast-n255 |
topic | Original Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8378085/ https://www.ncbi.nlm.nih.gov/pubmed/34485454 http://dx.doi.org/10.4102/sajid.v34i1.114 |
work_keys_str_mv | AT youngandreal theaccuracyofextendedspectrumbetalactamasedetectioninescherichiacoliandklebsiellapneumoniaeinsouthafricanlaboratoriesusingthevitek2gramnegativesusceptibilitycardastn255 AT nicolmarkp theaccuracyofextendedspectrumbetalactamasedetectioninescherichiacoliandklebsiellapneumoniaeinsouthafricanlaboratoriesusingthevitek2gramnegativesusceptibilitycardastn255 AT moodleyclinton theaccuracyofextendedspectrumbetalactamasedetectioninescherichiacoliandklebsiellapneumoniaeinsouthafricanlaboratoriesusingthevitek2gramnegativesusceptibilitycardastn255 AT bamfordcolleenm theaccuracyofextendedspectrumbetalactamasedetectioninescherichiacoliandklebsiellapneumoniaeinsouthafricanlaboratoriesusingthevitek2gramnegativesusceptibilitycardastn255 AT youngandreal accuracyofextendedspectrumbetalactamasedetectioninescherichiacoliandklebsiellapneumoniaeinsouthafricanlaboratoriesusingthevitek2gramnegativesusceptibilitycardastn255 AT nicolmarkp accuracyofextendedspectrumbetalactamasedetectioninescherichiacoliandklebsiellapneumoniaeinsouthafricanlaboratoriesusingthevitek2gramnegativesusceptibilitycardastn255 AT moodleyclinton accuracyofextendedspectrumbetalactamasedetectioninescherichiacoliandklebsiellapneumoniaeinsouthafricanlaboratoriesusingthevitek2gramnegativesusceptibilitycardastn255 AT bamfordcolleenm accuracyofextendedspectrumbetalactamasedetectioninescherichiacoliandklebsiellapneumoniaeinsouthafricanlaboratoriesusingthevitek2gramnegativesusceptibilitycardastn255 |