The accuracy of two electronic apex locators on effect of preflaring and file size: An in vitro study
AIM: This study was conducted to evaluate the effect of preflaring and file size on the accuracy of the Root ZX and E-PEX Pro electronic apex locators (EALs). MATERIALS AND METHODS: The actual working length was set 1 mm short of the apical foramen in the forty extracted mandibular premolars. The te...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Wolters Kluwer - Medknow
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8378484/ https://www.ncbi.nlm.nih.gov/pubmed/34475679 http://dx.doi.org/10.4103/JCD.JCD_4_19 |
_version_ | 1783740839360462848 |
---|---|
author | Saritha, V. Raghu, H. Kumar, Twino H. Totad, Shrishail Kamatagi, Laxmikant Saraf, Prahlad A. |
author_facet | Saritha, V. Raghu, H. Kumar, Twino H. Totad, Shrishail Kamatagi, Laxmikant Saraf, Prahlad A. |
author_sort | Saritha, V. |
collection | PubMed |
description | AIM: This study was conducted to evaluate the effect of preflaring and file size on the accuracy of the Root ZX and E-PEX Pro electronic apex locators (EALs). MATERIALS AND METHODS: The actual working length was set 1 mm short of the apical foramen in the forty extracted mandibular premolars. The teeth were embedded in an alginate mold, and two examiners performed the electronic measurements using #10, #15, and #20 K-files. The files were inserted into the root canals until the “0.0” or “APEX” signals were observed on the light-emitting diode or display screens for the E-PEX Pro and Root ZX, respectively, retracting to the 1.0 mark. The measurements were repeated after the preflaring using the S1 and SX Pro-Taper instruments. The mean differences between the actual length and electronic length values were analyzed by the Wilcoxon signed-ranked test with a significance level of P < 0.05. The factors evaluated were “Accuracy of EALs,” “size of file,” and “presence of preflaring. RESULTS: No significant differences were observed in the accuracy of both EALs when compared with the actual lengths. On the size of the file, significant difference noticed with #20 K-file. The preflaring procedure significantly (P < 0.05) increased the accuracy of the measurements for the Root ZX and Epex Pro. CONCLUSIONS: The tested EALs showed acceptable accuracy, whereas the preflaring procedure revealed a more significant effect than the used file size. |
format | Online Article Text |
id | pubmed-8378484 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Wolters Kluwer - Medknow |
record_format | MEDLINE/PubMed |
spelling | pubmed-83784842021-09-01 The accuracy of two electronic apex locators on effect of preflaring and file size: An in vitro study Saritha, V. Raghu, H. Kumar, Twino H. Totad, Shrishail Kamatagi, Laxmikant Saraf, Prahlad A. J Conserv Dent Original Article AIM: This study was conducted to evaluate the effect of preflaring and file size on the accuracy of the Root ZX and E-PEX Pro electronic apex locators (EALs). MATERIALS AND METHODS: The actual working length was set 1 mm short of the apical foramen in the forty extracted mandibular premolars. The teeth were embedded in an alginate mold, and two examiners performed the electronic measurements using #10, #15, and #20 K-files. The files were inserted into the root canals until the “0.0” or “APEX” signals were observed on the light-emitting diode or display screens for the E-PEX Pro and Root ZX, respectively, retracting to the 1.0 mark. The measurements were repeated after the preflaring using the S1 and SX Pro-Taper instruments. The mean differences between the actual length and electronic length values were analyzed by the Wilcoxon signed-ranked test with a significance level of P < 0.05. The factors evaluated were “Accuracy of EALs,” “size of file,” and “presence of preflaring. RESULTS: No significant differences were observed in the accuracy of both EALs when compared with the actual lengths. On the size of the file, significant difference noticed with #20 K-file. The preflaring procedure significantly (P < 0.05) increased the accuracy of the measurements for the Root ZX and Epex Pro. CONCLUSIONS: The tested EALs showed acceptable accuracy, whereas the preflaring procedure revealed a more significant effect than the used file size. Wolters Kluwer - Medknow 2021 2021-07-05 /pmc/articles/PMC8378484/ /pubmed/34475679 http://dx.doi.org/10.4103/JCD.JCD_4_19 Text en Copyright: © 2021 Journal of Conservative Dentistry https://creativecommons.org/licenses/by-nc-sa/4.0/This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms. |
spellingShingle | Original Article Saritha, V. Raghu, H. Kumar, Twino H. Totad, Shrishail Kamatagi, Laxmikant Saraf, Prahlad A. The accuracy of two electronic apex locators on effect of preflaring and file size: An in vitro study |
title | The accuracy of two electronic apex locators on effect of preflaring and file size: An in vitro study |
title_full | The accuracy of two electronic apex locators on effect of preflaring and file size: An in vitro study |
title_fullStr | The accuracy of two electronic apex locators on effect of preflaring and file size: An in vitro study |
title_full_unstemmed | The accuracy of two electronic apex locators on effect of preflaring and file size: An in vitro study |
title_short | The accuracy of two electronic apex locators on effect of preflaring and file size: An in vitro study |
title_sort | accuracy of two electronic apex locators on effect of preflaring and file size: an in vitro study |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8378484/ https://www.ncbi.nlm.nih.gov/pubmed/34475679 http://dx.doi.org/10.4103/JCD.JCD_4_19 |
work_keys_str_mv | AT sarithav theaccuracyoftwoelectronicapexlocatorsoneffectofpreflaringandfilesizeaninvitrostudy AT raghuh theaccuracyoftwoelectronicapexlocatorsoneffectofpreflaringandfilesizeaninvitrostudy AT kumartwinoh theaccuracyoftwoelectronicapexlocatorsoneffectofpreflaringandfilesizeaninvitrostudy AT totadshrishail theaccuracyoftwoelectronicapexlocatorsoneffectofpreflaringandfilesizeaninvitrostudy AT kamatagilaxmikant theaccuracyoftwoelectronicapexlocatorsoneffectofpreflaringandfilesizeaninvitrostudy AT sarafprahlada theaccuracyoftwoelectronicapexlocatorsoneffectofpreflaringandfilesizeaninvitrostudy AT sarithav accuracyoftwoelectronicapexlocatorsoneffectofpreflaringandfilesizeaninvitrostudy AT raghuh accuracyoftwoelectronicapexlocatorsoneffectofpreflaringandfilesizeaninvitrostudy AT kumartwinoh accuracyoftwoelectronicapexlocatorsoneffectofpreflaringandfilesizeaninvitrostudy AT totadshrishail accuracyoftwoelectronicapexlocatorsoneffectofpreflaringandfilesizeaninvitrostudy AT kamatagilaxmikant accuracyoftwoelectronicapexlocatorsoneffectofpreflaringandfilesizeaninvitrostudy AT sarafprahlada accuracyoftwoelectronicapexlocatorsoneffectofpreflaringandfilesizeaninvitrostudy |