Establishing Reproducibility and Correlation of Cochlear Microphonic Amplitude to Implant Electrode Position Using Intraoperative Electrocochleography and Postoperative Cone Beam Computed Tomography
OBJECTIVES: The primary objective of this study was to establish the reproducibility of cochlear microphonic (CM) recordings obtained from a cochlear implant (CI) electrode contact during and immediately after insertion. This was achieved by evaluating the insertion angle and calculating the positio...
Autores principales: | Soulby, Andrew, Connor, Steve, Jiang, Dan, Nunn, Terry, Boyle, Patrick, Pai, Irumee |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Lippincott Williams & Wilkins
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8378545/ https://www.ncbi.nlm.nih.gov/pubmed/33813521 http://dx.doi.org/10.1097/AUD.0000000000001010 |
Ejemplares similares
-
Utilizing Electrocochleography as a Microphone for Fully Implantable Cochlear Implants
por: Riggs, William Jason, et al.
Publicado: (2020) -
Self-assessment of cochlear health by cochlear implant recipients
por: Mushtaq, Faizah, et al.
Publicado: (2022) -
Robot-Assisted Electrode Insertion in Cochlear Implantation Controlled by Intraoperative Electrocochleography—A Pilot Study
por: Gawęcki, Wojciech, et al.
Publicado: (2022) -
A Model-Based Approach for Separating the Cochlear Microphonic from the Auditory Nerve Neurophonic in the Ongoing Response Using Electrocochleography
por: Fontenot, Tatyana E., et al.
Publicado: (2017) -
Multi-Frequency Electrocochleography and Electrode Scan to Identify Electrode Insertion Trauma during Cochlear Implantation
por: Saoji, Aniket A., et al.
Publicado: (2023)