Cargando…
Reduced-iodine-dose dual-energy coronary CT angiography: qualitative and quantitative comparison between virtual monochromatic and polychromatic CT images
OBJECTIVES: To quantitatively evaluate the impact of virtual monochromatic images (VMI) on reduced-iodine-dose dual-energy coronary computed tomography angiography (CCTA) in terms of coronary lumen segmentation in vitro, and secondly to assess the image quality in vivo, compared with conventional CT...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer Berlin Heidelberg
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8379124/ https://www.ncbi.nlm.nih.gov/pubmed/33740093 http://dx.doi.org/10.1007/s00330-021-07809-w |
_version_ | 1783740945549754368 |
---|---|
author | Rotzinger, David C. Si-Mohamed, Salim A. Yerly, Jérôme Boccalini, Sara Becce, Fabio Boussel, Loïc Meuli, Reto A. Qanadli, Salah D. Douek, Philippe C. |
author_facet | Rotzinger, David C. Si-Mohamed, Salim A. Yerly, Jérôme Boccalini, Sara Becce, Fabio Boussel, Loïc Meuli, Reto A. Qanadli, Salah D. Douek, Philippe C. |
author_sort | Rotzinger, David C. |
collection | PubMed |
description | OBJECTIVES: To quantitatively evaluate the impact of virtual monochromatic images (VMI) on reduced-iodine-dose dual-energy coronary computed tomography angiography (CCTA) in terms of coronary lumen segmentation in vitro, and secondly to assess the image quality in vivo, compared with conventional CT obtained with regular iodine dose. MATERIALS AND METHODS: A phantom simulating regular and reduced iodine injection was used to determine the accuracy and precision of lumen area segmentation for various VMI energy levels. We retrospectively included 203 patients from December 2017 to August 2018 (mean age, 51.7 ± 16.8 years) who underwent CCTA using either standard (group A, n = 103) or reduced (group B, n = 100) iodine doses. Conventional images (group A) were qualitatively and quantitatively compared with 55-keV VMI (group B). We recorded the location of venous catheters. RESULTS: In vitro, VMI outperformed conventional CT, with a segmentation accuracy of 0.998 vs. 1.684 mm(2), respectively (p < 0.001), and a precision of 0.982 vs. 1.229 mm(2), respectively (p < 0.001), in simulated overweight adult subjects. In vivo, the rate of diagnostic CCTA in groups A and B was 88.4% (n = 91/103) vs. 89% (n = 89/100), respectively, and noninferiority of protocol B was inferred. Contrast-to-noise ratios (CNR) of lumen versus fat and muscle were higher in group B (p < 0.001) and comparable for lumen versus calcium (p = 0.423). Venous catheters were more often placed on the forearm or hand in group B (p < 0.001). CONCLUSION: In vitro, low-keV VMI improve vessel area segmentation. In vivo, low-keV VMI allows for a 40% iodine dose and injection rate reduction while maintaining diagnostic image quality and improves the CNR between lumen versus fat and muscle. KEY POINTS: • Dual-energy coronary CT angiography is becoming increasingly available and might help improve patient management. • Compared with regular-iodine-dose coronary CT angiography, reduced-iodine-dose dual-energy CT with low-keV monochromatic image reconstructions performed better in phantom-based vessel cross-sectional segmentation and proved to be noninferior in vivo. • Patients receiving reduced-iodine-dose dual-energy coronary CT angiography often had the venous catheter placed on the forearm or wrist without compromising image quality. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s00330-021-07809-w. |
format | Online Article Text |
id | pubmed-8379124 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Springer Berlin Heidelberg |
record_format | MEDLINE/PubMed |
spelling | pubmed-83791242021-09-02 Reduced-iodine-dose dual-energy coronary CT angiography: qualitative and quantitative comparison between virtual monochromatic and polychromatic CT images Rotzinger, David C. Si-Mohamed, Salim A. Yerly, Jérôme Boccalini, Sara Becce, Fabio Boussel, Loïc Meuli, Reto A. Qanadli, Salah D. Douek, Philippe C. Eur Radiol Cardiac OBJECTIVES: To quantitatively evaluate the impact of virtual monochromatic images (VMI) on reduced-iodine-dose dual-energy coronary computed tomography angiography (CCTA) in terms of coronary lumen segmentation in vitro, and secondly to assess the image quality in vivo, compared with conventional CT obtained with regular iodine dose. MATERIALS AND METHODS: A phantom simulating regular and reduced iodine injection was used to determine the accuracy and precision of lumen area segmentation for various VMI energy levels. We retrospectively included 203 patients from December 2017 to August 2018 (mean age, 51.7 ± 16.8 years) who underwent CCTA using either standard (group A, n = 103) or reduced (group B, n = 100) iodine doses. Conventional images (group A) were qualitatively and quantitatively compared with 55-keV VMI (group B). We recorded the location of venous catheters. RESULTS: In vitro, VMI outperformed conventional CT, with a segmentation accuracy of 0.998 vs. 1.684 mm(2), respectively (p < 0.001), and a precision of 0.982 vs. 1.229 mm(2), respectively (p < 0.001), in simulated overweight adult subjects. In vivo, the rate of diagnostic CCTA in groups A and B was 88.4% (n = 91/103) vs. 89% (n = 89/100), respectively, and noninferiority of protocol B was inferred. Contrast-to-noise ratios (CNR) of lumen versus fat and muscle were higher in group B (p < 0.001) and comparable for lumen versus calcium (p = 0.423). Venous catheters were more often placed on the forearm or hand in group B (p < 0.001). CONCLUSION: In vitro, low-keV VMI improve vessel area segmentation. In vivo, low-keV VMI allows for a 40% iodine dose and injection rate reduction while maintaining diagnostic image quality and improves the CNR between lumen versus fat and muscle. KEY POINTS: • Dual-energy coronary CT angiography is becoming increasingly available and might help improve patient management. • Compared with regular-iodine-dose coronary CT angiography, reduced-iodine-dose dual-energy CT with low-keV monochromatic image reconstructions performed better in phantom-based vessel cross-sectional segmentation and proved to be noninferior in vivo. • Patients receiving reduced-iodine-dose dual-energy coronary CT angiography often had the venous catheter placed on the forearm or wrist without compromising image quality. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s00330-021-07809-w. Springer Berlin Heidelberg 2021-03-19 2021 /pmc/articles/PMC8379124/ /pubmed/33740093 http://dx.doi.org/10.1007/s00330-021-07809-w Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . |
spellingShingle | Cardiac Rotzinger, David C. Si-Mohamed, Salim A. Yerly, Jérôme Boccalini, Sara Becce, Fabio Boussel, Loïc Meuli, Reto A. Qanadli, Salah D. Douek, Philippe C. Reduced-iodine-dose dual-energy coronary CT angiography: qualitative and quantitative comparison between virtual monochromatic and polychromatic CT images |
title | Reduced-iodine-dose dual-energy coronary CT angiography: qualitative and quantitative comparison between virtual monochromatic and polychromatic CT images |
title_full | Reduced-iodine-dose dual-energy coronary CT angiography: qualitative and quantitative comparison between virtual monochromatic and polychromatic CT images |
title_fullStr | Reduced-iodine-dose dual-energy coronary CT angiography: qualitative and quantitative comparison between virtual monochromatic and polychromatic CT images |
title_full_unstemmed | Reduced-iodine-dose dual-energy coronary CT angiography: qualitative and quantitative comparison between virtual monochromatic and polychromatic CT images |
title_short | Reduced-iodine-dose dual-energy coronary CT angiography: qualitative and quantitative comparison between virtual monochromatic and polychromatic CT images |
title_sort | reduced-iodine-dose dual-energy coronary ct angiography: qualitative and quantitative comparison between virtual monochromatic and polychromatic ct images |
topic | Cardiac |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8379124/ https://www.ncbi.nlm.nih.gov/pubmed/33740093 http://dx.doi.org/10.1007/s00330-021-07809-w |
work_keys_str_mv | AT rotzingerdavidc reducediodinedosedualenergycoronaryctangiographyqualitativeandquantitativecomparisonbetweenvirtualmonochromaticandpolychromaticctimages AT simohamedsalima reducediodinedosedualenergycoronaryctangiographyqualitativeandquantitativecomparisonbetweenvirtualmonochromaticandpolychromaticctimages AT yerlyjerome reducediodinedosedualenergycoronaryctangiographyqualitativeandquantitativecomparisonbetweenvirtualmonochromaticandpolychromaticctimages AT boccalinisara reducediodinedosedualenergycoronaryctangiographyqualitativeandquantitativecomparisonbetweenvirtualmonochromaticandpolychromaticctimages AT beccefabio reducediodinedosedualenergycoronaryctangiographyqualitativeandquantitativecomparisonbetweenvirtualmonochromaticandpolychromaticctimages AT bousselloic reducediodinedosedualenergycoronaryctangiographyqualitativeandquantitativecomparisonbetweenvirtualmonochromaticandpolychromaticctimages AT meuliretoa reducediodinedosedualenergycoronaryctangiographyqualitativeandquantitativecomparisonbetweenvirtualmonochromaticandpolychromaticctimages AT qanadlisalahd reducediodinedosedualenergycoronaryctangiographyqualitativeandquantitativecomparisonbetweenvirtualmonochromaticandpolychromaticctimages AT douekphilippec reducediodinedosedualenergycoronaryctangiographyqualitativeandquantitativecomparisonbetweenvirtualmonochromaticandpolychromaticctimages |