Cargando…

Acoustic and flow data of fluidic and piezoelectric ultrasonic transducers

This data article presents characteristic acoustic and flow data of a fluidic ultrasonic transducer as well as acoustic data of a commercial piezoelectric ultrasonic transducer used in non-destructive testing for civil engineering. The flow data has been acquired using hot-wire anemometry and a Pito...

Descripción completa

Detalles Bibliográficos
Autores principales: Bühling, Benjamin, Maack, Stefan, Schönsee, Eric, Schweitzer, Thorge, Strangfeld, Christoph
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8379259/
https://www.ncbi.nlm.nih.gov/pubmed/34458514
http://dx.doi.org/10.1016/j.dib.2021.107280
_version_ 1783740972891373568
author Bühling, Benjamin
Maack, Stefan
Schönsee, Eric
Schweitzer, Thorge
Strangfeld, Christoph
author_facet Bühling, Benjamin
Maack, Stefan
Schönsee, Eric
Schweitzer, Thorge
Strangfeld, Christoph
author_sort Bühling, Benjamin
collection PubMed
description This data article presents characteristic acoustic and flow data of a fluidic ultrasonic transducer as well as acoustic data of a commercial piezoelectric ultrasonic transducer used in non-destructive testing for civil engineering. The flow data has been acquired using hot-wire anemometry and a Pitot tube. The three-dimensional acoustic data of both devices has been acquired using a calibrated microphone. The distribution of characteristic acoustic properties of both transducers are extracted and given in addition to the raw data. The data presented in the article will be a valuable source for reference and validation, both for developing fluidic and alternate ultrasound generation technologies. Furthermore, they will give additional insight into the acoustic-flow interaction phenomena of high speed switching devices. This article is accompanying the paper Experimental Analysis of the Acoustic Field of an Ultrasonic Pulse Induced by a Fluidic Switch (Bühling et al., 2021) published in The Journal of the Acoustical Society of America, where the data is interpreted in detail and the rationale for characteristic sound properties of the fluidic transducer are given.
format Online
Article
Text
id pubmed-8379259
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-83792592021-08-26 Acoustic and flow data of fluidic and piezoelectric ultrasonic transducers Bühling, Benjamin Maack, Stefan Schönsee, Eric Schweitzer, Thorge Strangfeld, Christoph Data Brief Data Article This data article presents characteristic acoustic and flow data of a fluidic ultrasonic transducer as well as acoustic data of a commercial piezoelectric ultrasonic transducer used in non-destructive testing for civil engineering. The flow data has been acquired using hot-wire anemometry and a Pitot tube. The three-dimensional acoustic data of both devices has been acquired using a calibrated microphone. The distribution of characteristic acoustic properties of both transducers are extracted and given in addition to the raw data. The data presented in the article will be a valuable source for reference and validation, both for developing fluidic and alternate ultrasound generation technologies. Furthermore, they will give additional insight into the acoustic-flow interaction phenomena of high speed switching devices. This article is accompanying the paper Experimental Analysis of the Acoustic Field of an Ultrasonic Pulse Induced by a Fluidic Switch (Bühling et al., 2021) published in The Journal of the Acoustical Society of America, where the data is interpreted in detail and the rationale for characteristic sound properties of the fluidic transducer are given. Elsevier 2021-08-13 /pmc/articles/PMC8379259/ /pubmed/34458514 http://dx.doi.org/10.1016/j.dib.2021.107280 Text en © 2021 The Author(s) https://creativecommons.org/licenses/by/4.0/This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Data Article
Bühling, Benjamin
Maack, Stefan
Schönsee, Eric
Schweitzer, Thorge
Strangfeld, Christoph
Acoustic and flow data of fluidic and piezoelectric ultrasonic transducers
title Acoustic and flow data of fluidic and piezoelectric ultrasonic transducers
title_full Acoustic and flow data of fluidic and piezoelectric ultrasonic transducers
title_fullStr Acoustic and flow data of fluidic and piezoelectric ultrasonic transducers
title_full_unstemmed Acoustic and flow data of fluidic and piezoelectric ultrasonic transducers
title_short Acoustic and flow data of fluidic and piezoelectric ultrasonic transducers
title_sort acoustic and flow data of fluidic and piezoelectric ultrasonic transducers
topic Data Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8379259/
https://www.ncbi.nlm.nih.gov/pubmed/34458514
http://dx.doi.org/10.1016/j.dib.2021.107280
work_keys_str_mv AT buhlingbenjamin acousticandflowdataoffluidicandpiezoelectricultrasonictransducers
AT maackstefan acousticandflowdataoffluidicandpiezoelectricultrasonictransducers
AT schonseeeric acousticandflowdataoffluidicandpiezoelectricultrasonictransducers
AT schweitzerthorge acousticandflowdataoffluidicandpiezoelectricultrasonictransducers
AT strangfeldchristoph acousticandflowdataoffluidicandpiezoelectricultrasonictransducers