Cargando…

Dosimetric impact of contrast-enhanced 4d computed tomography for stereotactic body radiation therapy of hepatocelluar carcinoma

BACKGROUND: A purpose of the study was to investigate the dosimetric impact of contrast media on dose calculation using average 4D contrast-enhanced computed tomography (4D-CECT) and delayed 4D-CT (d4D-CT) images caused by CT simulation contrast agents for stereotactic body radiation therapy (SBRT)...

Descripción completa

Detalles Bibliográficos
Autores principales: Kamal, Rose, Thaper, Deepak, Kumar, Rishabh, Singh, Gaganpreet, Yadav, Hanuman P., Oinam, Arun S., Kumar, Vivek, Sharma, Hitesh
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Via Medica 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8382070/
https://www.ncbi.nlm.nih.gov/pubmed/34434576
http://dx.doi.org/10.5603/RPOR.a2021.0075
_version_ 1783741480947417088
author Kamal, Rose
Thaper, Deepak
Kumar, Rishabh
Singh, Gaganpreet
Yadav, Hanuman P.
Oinam, Arun S.
Kumar, Vivek
Sharma, Hitesh
author_facet Kamal, Rose
Thaper, Deepak
Kumar, Rishabh
Singh, Gaganpreet
Yadav, Hanuman P.
Oinam, Arun S.
Kumar, Vivek
Sharma, Hitesh
author_sort Kamal, Rose
collection PubMed
description BACKGROUND: A purpose of the study was to investigate the dosimetric impact of contrast media on dose calculation using average 4D contrast-enhanced computed tomography (4D-CECT) and delayed 4D-CT (d4D-CT) images caused by CT simulation contrast agents for stereotactic body radiation therapy (SBRT) of liver cases. MATERIALS AND METHODS: Fifteen patients of liver SBRT treated using the volumetric modulated arc therapy (VMAT) technique were selected retrospectively. 4D-CECT, and d4D-CT were acquired with the Anzai gating system and GE CT. For all patients, gross target volume (GTV) was contoured on the ten phases after rigid registration of both the contrast and delayed scans and merged to generate internal target volume (ITV) on average CT images. Region of interest (ROI) was drawn on contrast images and then copied to the delayed images after rigid registration of two average CT datasets. The treatment plans were generated for contrast enhanced average CT, delayed average CT and contrast enhanced average CT with electron density of the heart overridden. RESULTS: No significant dosimetric difference was observed in plans parameters (mean HU value of the liver, total monitor units, total control points, degree of modulation and average segment area) except mean HU value of the aorta amongst the three arms. All the OARs were evaluated and resulted in statistically insignificant variation (p > 0.05) using one way ANOVA analysis. CONCLUSIONS: Contrast enhanced 4D-CT is advantageous in accurate delineation of tumors and assessing accurate ITV. The treatment plans generated on average 4D-CECT and average d4D-CT have a clinically insignificant effect on dosimetric parameters.
format Online
Article
Text
id pubmed-8382070
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Via Medica
record_format MEDLINE/PubMed
spelling pubmed-83820702021-08-24 Dosimetric impact of contrast-enhanced 4d computed tomography for stereotactic body radiation therapy of hepatocelluar carcinoma Kamal, Rose Thaper, Deepak Kumar, Rishabh Singh, Gaganpreet Yadav, Hanuman P. Oinam, Arun S. Kumar, Vivek Sharma, Hitesh Rep Pract Oncol Radiother Research Paper BACKGROUND: A purpose of the study was to investigate the dosimetric impact of contrast media on dose calculation using average 4D contrast-enhanced computed tomography (4D-CECT) and delayed 4D-CT (d4D-CT) images caused by CT simulation contrast agents for stereotactic body radiation therapy (SBRT) of liver cases. MATERIALS AND METHODS: Fifteen patients of liver SBRT treated using the volumetric modulated arc therapy (VMAT) technique were selected retrospectively. 4D-CECT, and d4D-CT were acquired with the Anzai gating system and GE CT. For all patients, gross target volume (GTV) was contoured on the ten phases after rigid registration of both the contrast and delayed scans and merged to generate internal target volume (ITV) on average CT images. Region of interest (ROI) was drawn on contrast images and then copied to the delayed images after rigid registration of two average CT datasets. The treatment plans were generated for contrast enhanced average CT, delayed average CT and contrast enhanced average CT with electron density of the heart overridden. RESULTS: No significant dosimetric difference was observed in plans parameters (mean HU value of the liver, total monitor units, total control points, degree of modulation and average segment area) except mean HU value of the aorta amongst the three arms. All the OARs were evaluated and resulted in statistically insignificant variation (p > 0.05) using one way ANOVA analysis. CONCLUSIONS: Contrast enhanced 4D-CT is advantageous in accurate delineation of tumors and assessing accurate ITV. The treatment plans generated on average 4D-CECT and average d4D-CT have a clinically insignificant effect on dosimetric parameters. Via Medica 2021-08-12 /pmc/articles/PMC8382070/ /pubmed/34434576 http://dx.doi.org/10.5603/RPOR.a2021.0075 Text en © 2021 Greater Poland Cancer Centre https://creativecommons.org/licenses/by-nc-nd/4.0/This article is available in open access under Creative Common Attribution-Non-Commercial-No Derivatives 4.0 International (CC BY-NC-ND 4.0) license, allowing to download articles and share them with others as long as they credit the authors and the publisher, but without permission to change them in any way or use them commercially
spellingShingle Research Paper
Kamal, Rose
Thaper, Deepak
Kumar, Rishabh
Singh, Gaganpreet
Yadav, Hanuman P.
Oinam, Arun S.
Kumar, Vivek
Sharma, Hitesh
Dosimetric impact of contrast-enhanced 4d computed tomography for stereotactic body radiation therapy of hepatocelluar carcinoma
title Dosimetric impact of contrast-enhanced 4d computed tomography for stereotactic body radiation therapy of hepatocelluar carcinoma
title_full Dosimetric impact of contrast-enhanced 4d computed tomography for stereotactic body radiation therapy of hepatocelluar carcinoma
title_fullStr Dosimetric impact of contrast-enhanced 4d computed tomography for stereotactic body radiation therapy of hepatocelluar carcinoma
title_full_unstemmed Dosimetric impact of contrast-enhanced 4d computed tomography for stereotactic body radiation therapy of hepatocelluar carcinoma
title_short Dosimetric impact of contrast-enhanced 4d computed tomography for stereotactic body radiation therapy of hepatocelluar carcinoma
title_sort dosimetric impact of contrast-enhanced 4d computed tomography for stereotactic body radiation therapy of hepatocelluar carcinoma
topic Research Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8382070/
https://www.ncbi.nlm.nih.gov/pubmed/34434576
http://dx.doi.org/10.5603/RPOR.a2021.0075
work_keys_str_mv AT kamalrose dosimetricimpactofcontrastenhanced4dcomputedtomographyforstereotacticbodyradiationtherapyofhepatocelluarcarcinoma
AT thaperdeepak dosimetricimpactofcontrastenhanced4dcomputedtomographyforstereotacticbodyradiationtherapyofhepatocelluarcarcinoma
AT kumarrishabh dosimetricimpactofcontrastenhanced4dcomputedtomographyforstereotacticbodyradiationtherapyofhepatocelluarcarcinoma
AT singhgaganpreet dosimetricimpactofcontrastenhanced4dcomputedtomographyforstereotacticbodyradiationtherapyofhepatocelluarcarcinoma
AT yadavhanumanp dosimetricimpactofcontrastenhanced4dcomputedtomographyforstereotacticbodyradiationtherapyofhepatocelluarcarcinoma
AT oinamaruns dosimetricimpactofcontrastenhanced4dcomputedtomographyforstereotacticbodyradiationtherapyofhepatocelluarcarcinoma
AT kumarvivek dosimetricimpactofcontrastenhanced4dcomputedtomographyforstereotacticbodyradiationtherapyofhepatocelluarcarcinoma
AT sharmahitesh dosimetricimpactofcontrastenhanced4dcomputedtomographyforstereotacticbodyradiationtherapyofhepatocelluarcarcinoma