Cargando…

Endovascular Stent-Graft Repair of the Ascending Aorta: Assessment of a Specific Novel Stent-Graft Design in Phantom, Cadaveric, and Clinical Application

PURPOSE: To test a stent-graft specifically designed for the ascending aorta in phantom, cadaver, and clinical application, and to measure deployment accuracy to overcome limitations of existing devices. METHODS: A stent-graft has been designed with support wires to fixate the apices toward the inne...

Descripción completa

Detalles Bibliográficos
Autores principales: Hauck, Sven R., Kupferthaler, Alexander, Stelzmüller, Marlies, Eilenberg, Wolf, Ehrlich, Marek, Neumayer, Christoph, Wolf, Florian, Loewe, Christian, Funovics, Martin A.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer US 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8382630/
https://www.ncbi.nlm.nih.gov/pubmed/34180002
http://dx.doi.org/10.1007/s00270-021-02859-5
_version_ 1783741573590155264
author Hauck, Sven R.
Kupferthaler, Alexander
Stelzmüller, Marlies
Eilenberg, Wolf
Ehrlich, Marek
Neumayer, Christoph
Wolf, Florian
Loewe, Christian
Funovics, Martin A.
author_facet Hauck, Sven R.
Kupferthaler, Alexander
Stelzmüller, Marlies
Eilenberg, Wolf
Ehrlich, Marek
Neumayer, Christoph
Wolf, Florian
Loewe, Christian
Funovics, Martin A.
author_sort Hauck, Sven R.
collection PubMed
description PURPOSE: To test a stent-graft specifically designed for the ascending aorta in phantom, cadaver, and clinical application, and to measure deployment accuracy to overcome limitations of existing devices. METHODS: A stent-graft has been designed with support wires to fixate the apices toward the inner curvature, thereby eliminating the forward movement of the proximal end which can happen with circumferential tip capture systems. The device was deployed in three aortic phantoms, and in four cadavers, deployment precision was measured. Subsequently, the device was implanted in a patient to exclude a pseudoaneurysm originating from the distal anastomosis after ascending aortic replacement. RESULTS: The stent-grafts were successfully deployed in all phantoms and cadavers. Deployment accuracy of the proximal end of the stent-graft was within 1 mm proximally and 14 mm distally to the intended landing zone on the inner curvature, and 2–8 mm distal to the intended landing zone on the outer curvature. In clinical application, the pseudoaneurysm could be successfully excluded without complications. CONCLUSION: The novel stent-graft design promises accurate placement in the ascending aorta. The differential deployment of the apices at the inner and outer curvatures allows deployment perpendicular to the aortic axis. LEVEL OF EVIDENCE: No level of evidence.
format Online
Article
Text
id pubmed-8382630
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Springer US
record_format MEDLINE/PubMed
spelling pubmed-83826302021-09-09 Endovascular Stent-Graft Repair of the Ascending Aorta: Assessment of a Specific Novel Stent-Graft Design in Phantom, Cadaveric, and Clinical Application Hauck, Sven R. Kupferthaler, Alexander Stelzmüller, Marlies Eilenberg, Wolf Ehrlich, Marek Neumayer, Christoph Wolf, Florian Loewe, Christian Funovics, Martin A. Cardiovasc Intervent Radiol Laboratory Investigation PURPOSE: To test a stent-graft specifically designed for the ascending aorta in phantom, cadaver, and clinical application, and to measure deployment accuracy to overcome limitations of existing devices. METHODS: A stent-graft has been designed with support wires to fixate the apices toward the inner curvature, thereby eliminating the forward movement of the proximal end which can happen with circumferential tip capture systems. The device was deployed in three aortic phantoms, and in four cadavers, deployment precision was measured. Subsequently, the device was implanted in a patient to exclude a pseudoaneurysm originating from the distal anastomosis after ascending aortic replacement. RESULTS: The stent-grafts were successfully deployed in all phantoms and cadavers. Deployment accuracy of the proximal end of the stent-graft was within 1 mm proximally and 14 mm distally to the intended landing zone on the inner curvature, and 2–8 mm distal to the intended landing zone on the outer curvature. In clinical application, the pseudoaneurysm could be successfully excluded without complications. CONCLUSION: The novel stent-graft design promises accurate placement in the ascending aorta. The differential deployment of the apices at the inner and outer curvatures allows deployment perpendicular to the aortic axis. LEVEL OF EVIDENCE: No level of evidence. Springer US 2021-06-27 2021 /pmc/articles/PMC8382630/ /pubmed/34180002 http://dx.doi.org/10.1007/s00270-021-02859-5 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Laboratory Investigation
Hauck, Sven R.
Kupferthaler, Alexander
Stelzmüller, Marlies
Eilenberg, Wolf
Ehrlich, Marek
Neumayer, Christoph
Wolf, Florian
Loewe, Christian
Funovics, Martin A.
Endovascular Stent-Graft Repair of the Ascending Aorta: Assessment of a Specific Novel Stent-Graft Design in Phantom, Cadaveric, and Clinical Application
title Endovascular Stent-Graft Repair of the Ascending Aorta: Assessment of a Specific Novel Stent-Graft Design in Phantom, Cadaveric, and Clinical Application
title_full Endovascular Stent-Graft Repair of the Ascending Aorta: Assessment of a Specific Novel Stent-Graft Design in Phantom, Cadaveric, and Clinical Application
title_fullStr Endovascular Stent-Graft Repair of the Ascending Aorta: Assessment of a Specific Novel Stent-Graft Design in Phantom, Cadaveric, and Clinical Application
title_full_unstemmed Endovascular Stent-Graft Repair of the Ascending Aorta: Assessment of a Specific Novel Stent-Graft Design in Phantom, Cadaveric, and Clinical Application
title_short Endovascular Stent-Graft Repair of the Ascending Aorta: Assessment of a Specific Novel Stent-Graft Design in Phantom, Cadaveric, and Clinical Application
title_sort endovascular stent-graft repair of the ascending aorta: assessment of a specific novel stent-graft design in phantom, cadaveric, and clinical application
topic Laboratory Investigation
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8382630/
https://www.ncbi.nlm.nih.gov/pubmed/34180002
http://dx.doi.org/10.1007/s00270-021-02859-5
work_keys_str_mv AT haucksvenr endovascularstentgraftrepairoftheascendingaortaassessmentofaspecificnovelstentgraftdesigninphantomcadavericandclinicalapplication
AT kupferthaleralexander endovascularstentgraftrepairoftheascendingaortaassessmentofaspecificnovelstentgraftdesigninphantomcadavericandclinicalapplication
AT stelzmullermarlies endovascularstentgraftrepairoftheascendingaortaassessmentofaspecificnovelstentgraftdesigninphantomcadavericandclinicalapplication
AT eilenbergwolf endovascularstentgraftrepairoftheascendingaortaassessmentofaspecificnovelstentgraftdesigninphantomcadavericandclinicalapplication
AT ehrlichmarek endovascularstentgraftrepairoftheascendingaortaassessmentofaspecificnovelstentgraftdesigninphantomcadavericandclinicalapplication
AT neumayerchristoph endovascularstentgraftrepairoftheascendingaortaassessmentofaspecificnovelstentgraftdesigninphantomcadavericandclinicalapplication
AT wolfflorian endovascularstentgraftrepairoftheascendingaortaassessmentofaspecificnovelstentgraftdesigninphantomcadavericandclinicalapplication
AT loewechristian endovascularstentgraftrepairoftheascendingaortaassessmentofaspecificnovelstentgraftdesigninphantomcadavericandclinicalapplication
AT funovicsmartina endovascularstentgraftrepairoftheascendingaortaassessmentofaspecificnovelstentgraftdesigninphantomcadavericandclinicalapplication