Micro-CT yields high image quality in human fetal post-mortem imaging despite maceration
BACKGROUND: Current clinical post-mortem imaging techniques do not provide sufficiently high-resolution imaging for smaller fetuses after pregnancy loss. Post-mortem micro-CT is a non-invasive technique that can deliver high diagnostic accuracy for these smaller fetuses. The purpose of the study is...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8383392/ https://www.ncbi.nlm.nih.gov/pubmed/34429085 http://dx.doi.org/10.1186/s12880-021-00658-5 |
_version_ | 1783741729197785088 |
---|---|
author | Simcock, Ian Craig Shelmerdine, Susan Cheng Langan, Dean Anna, Guy Sebire, Neil James Arthurs, Owen John |
author_facet | Simcock, Ian Craig Shelmerdine, Susan Cheng Langan, Dean Anna, Guy Sebire, Neil James Arthurs, Owen John |
author_sort | Simcock, Ian Craig |
collection | PubMed |
description | BACKGROUND: Current clinical post-mortem imaging techniques do not provide sufficiently high-resolution imaging for smaller fetuses after pregnancy loss. Post-mortem micro-CT is a non-invasive technique that can deliver high diagnostic accuracy for these smaller fetuses. The purpose of the study is to identify the main predictors of image quality for human fetal post-mortem micro-CT imaging. METHODS: Human fetuses were imaged using micro-CT following potassium tri-iodide tissue preparation, and axial head and chest views were assessed for image quality on a Likert scale by two blinded radiologists. Simple and multivariable linear regression models were performed with demographic details, iodination, tissue maceration score and imaging parameters as predictor variables. RESULTS: 258 fetuses were assessed, with median weight 41.7 g (2.6–350 g) and mean gestational age 16 weeks (11–24 weeks). A high image quality score (> 6.5) was achieved in 95% of micro-CT studies, higher for the head (median = 9) than chest (median = 8.5) imaging. The strongest negative predictors of image quality were increasing maceration and body weight (p < 0.001), with number of projections being the best positive imaging predictor. CONCLUSIONS: High micro-CT image quality score is achievable following early pregnancy loss despite fetal maceration, particularly in smaller fetuses where conventional autopsy may be particularly challenging. These findings will help establish clinical micro-CT imaging services, addressing the need for less invasive fetal autopsy methods. |
format | Online Article Text |
id | pubmed-8383392 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-83833922021-08-25 Micro-CT yields high image quality in human fetal post-mortem imaging despite maceration Simcock, Ian Craig Shelmerdine, Susan Cheng Langan, Dean Anna, Guy Sebire, Neil James Arthurs, Owen John BMC Med Imaging Research BACKGROUND: Current clinical post-mortem imaging techniques do not provide sufficiently high-resolution imaging for smaller fetuses after pregnancy loss. Post-mortem micro-CT is a non-invasive technique that can deliver high diagnostic accuracy for these smaller fetuses. The purpose of the study is to identify the main predictors of image quality for human fetal post-mortem micro-CT imaging. METHODS: Human fetuses were imaged using micro-CT following potassium tri-iodide tissue preparation, and axial head and chest views were assessed for image quality on a Likert scale by two blinded radiologists. Simple and multivariable linear regression models were performed with demographic details, iodination, tissue maceration score and imaging parameters as predictor variables. RESULTS: 258 fetuses were assessed, with median weight 41.7 g (2.6–350 g) and mean gestational age 16 weeks (11–24 weeks). A high image quality score (> 6.5) was achieved in 95% of micro-CT studies, higher for the head (median = 9) than chest (median = 8.5) imaging. The strongest negative predictors of image quality were increasing maceration and body weight (p < 0.001), with number of projections being the best positive imaging predictor. CONCLUSIONS: High micro-CT image quality score is achievable following early pregnancy loss despite fetal maceration, particularly in smaller fetuses where conventional autopsy may be particularly challenging. These findings will help establish clinical micro-CT imaging services, addressing the need for less invasive fetal autopsy methods. BioMed Central 2021-08-24 /pmc/articles/PMC8383392/ /pubmed/34429085 http://dx.doi.org/10.1186/s12880-021-00658-5 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Simcock, Ian Craig Shelmerdine, Susan Cheng Langan, Dean Anna, Guy Sebire, Neil James Arthurs, Owen John Micro-CT yields high image quality in human fetal post-mortem imaging despite maceration |
title | Micro-CT yields high image quality in human fetal post-mortem imaging despite maceration |
title_full | Micro-CT yields high image quality in human fetal post-mortem imaging despite maceration |
title_fullStr | Micro-CT yields high image quality in human fetal post-mortem imaging despite maceration |
title_full_unstemmed | Micro-CT yields high image quality in human fetal post-mortem imaging despite maceration |
title_short | Micro-CT yields high image quality in human fetal post-mortem imaging despite maceration |
title_sort | micro-ct yields high image quality in human fetal post-mortem imaging despite maceration |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8383392/ https://www.ncbi.nlm.nih.gov/pubmed/34429085 http://dx.doi.org/10.1186/s12880-021-00658-5 |
work_keys_str_mv | AT simcockiancraig microctyieldshighimagequalityinhumanfetalpostmortemimagingdespitemaceration AT shelmerdinesusancheng microctyieldshighimagequalityinhumanfetalpostmortemimagingdespitemaceration AT langandean microctyieldshighimagequalityinhumanfetalpostmortemimagingdespitemaceration AT annaguy microctyieldshighimagequalityinhumanfetalpostmortemimagingdespitemaceration AT sebireneiljames microctyieldshighimagequalityinhumanfetalpostmortemimagingdespitemaceration AT arthursowenjohn microctyieldshighimagequalityinhumanfetalpostmortemimagingdespitemaceration |