Cargando…

A New Technique for Seprafilm(®) That Can Be Practiced with a 5-mm Trocar

Seprafilm(®) is an adhesion barrier sheet. However, it is difficult to handle it through a 5-mm trocar. We have devised a method of applying Seprafilm(®) safely and reliably through a 5-mm trocar by using a holder that comes with the film. We practiced this method in three cases of total laparoscopi...

Descripción completa

Detalles Bibliográficos
Autores principales: Sano, Rikiya, Ota, Yoshiaki, Tanaka, Tamaki, Suzuki, Soichiro, Shimoya, Koichiro, Shiota, Mitsuru
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer - Medknow 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8384026/
https://www.ncbi.nlm.nih.gov/pubmed/34485062
http://dx.doi.org/10.4103/GMIT.GMIT_36_20
_version_ 1783741841644978176
author Sano, Rikiya
Ota, Yoshiaki
Tanaka, Tamaki
Suzuki, Soichiro
Shimoya, Koichiro
Shiota, Mitsuru
author_facet Sano, Rikiya
Ota, Yoshiaki
Tanaka, Tamaki
Suzuki, Soichiro
Shimoya, Koichiro
Shiota, Mitsuru
author_sort Sano, Rikiya
collection PubMed
description Seprafilm(®) is an adhesion barrier sheet. However, it is difficult to handle it through a 5-mm trocar. We have devised a method of applying Seprafilm(®) safely and reliably through a 5-mm trocar by using a holder that comes with the film. We practiced this method in three cases of total laparoscopic hysterectomy for uterine leiomyoma. The quarter-pack is cut into three pieces. The film placed on the holder sheet was rolled up with forceps (or wrapped around forceps) and inserted into a 5 mm trocar. After application, the center of the short axis of the holder was pinched with a grasping forceps, and the holder was drawn out of the body through the trocar. Of the 36 pieces placed, Seprafilm(®) broke only in once. Insertion was successful in 100%, and the holder was successfully retrieved through the trocar in 92% (33/36) of the cases. The holder may be easily retrieved after application. This technique represents an extremely simple versatile application method in operations in which only 5-mm trocars can be used.
format Online
Article
Text
id pubmed-8384026
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Wolters Kluwer - Medknow
record_format MEDLINE/PubMed
spelling pubmed-83840262021-09-02 A New Technique for Seprafilm(®) That Can Be Practiced with a 5-mm Trocar Sano, Rikiya Ota, Yoshiaki Tanaka, Tamaki Suzuki, Soichiro Shimoya, Koichiro Shiota, Mitsuru Gynecol Minim Invasive Ther Short Communication Seprafilm(®) is an adhesion barrier sheet. However, it is difficult to handle it through a 5-mm trocar. We have devised a method of applying Seprafilm(®) safely and reliably through a 5-mm trocar by using a holder that comes with the film. We practiced this method in three cases of total laparoscopic hysterectomy for uterine leiomyoma. The quarter-pack is cut into three pieces. The film placed on the holder sheet was rolled up with forceps (or wrapped around forceps) and inserted into a 5 mm trocar. After application, the center of the short axis of the holder was pinched with a grasping forceps, and the holder was drawn out of the body through the trocar. Of the 36 pieces placed, Seprafilm(®) broke only in once. Insertion was successful in 100%, and the holder was successfully retrieved through the trocar in 92% (33/36) of the cases. The holder may be easily retrieved after application. This technique represents an extremely simple versatile application method in operations in which only 5-mm trocars can be used. Wolters Kluwer - Medknow 2021-08-03 /pmc/articles/PMC8384026/ /pubmed/34485062 http://dx.doi.org/10.4103/GMIT.GMIT_36_20 Text en Copyright: © 2021 Gynecology and Minimally Invasive Therapy https://creativecommons.org/licenses/by-nc-sa/4.0/This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
spellingShingle Short Communication
Sano, Rikiya
Ota, Yoshiaki
Tanaka, Tamaki
Suzuki, Soichiro
Shimoya, Koichiro
Shiota, Mitsuru
A New Technique for Seprafilm(®) That Can Be Practiced with a 5-mm Trocar
title A New Technique for Seprafilm(®) That Can Be Practiced with a 5-mm Trocar
title_full A New Technique for Seprafilm(®) That Can Be Practiced with a 5-mm Trocar
title_fullStr A New Technique for Seprafilm(®) That Can Be Practiced with a 5-mm Trocar
title_full_unstemmed A New Technique for Seprafilm(®) That Can Be Practiced with a 5-mm Trocar
title_short A New Technique for Seprafilm(®) That Can Be Practiced with a 5-mm Trocar
title_sort new technique for seprafilm(®) that can be practiced with a 5-mm trocar
topic Short Communication
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8384026/
https://www.ncbi.nlm.nih.gov/pubmed/34485062
http://dx.doi.org/10.4103/GMIT.GMIT_36_20
work_keys_str_mv AT sanorikiya anewtechniqueforseprafilmthatcanbepracticedwitha5mmtrocar
AT otayoshiaki anewtechniqueforseprafilmthatcanbepracticedwitha5mmtrocar
AT tanakatamaki anewtechniqueforseprafilmthatcanbepracticedwitha5mmtrocar
AT suzukisoichiro anewtechniqueforseprafilmthatcanbepracticedwitha5mmtrocar
AT shimoyakoichiro anewtechniqueforseprafilmthatcanbepracticedwitha5mmtrocar
AT shiotamitsuru anewtechniqueforseprafilmthatcanbepracticedwitha5mmtrocar
AT sanorikiya newtechniqueforseprafilmthatcanbepracticedwitha5mmtrocar
AT otayoshiaki newtechniqueforseprafilmthatcanbepracticedwitha5mmtrocar
AT tanakatamaki newtechniqueforseprafilmthatcanbepracticedwitha5mmtrocar
AT suzukisoichiro newtechniqueforseprafilmthatcanbepracticedwitha5mmtrocar
AT shimoyakoichiro newtechniqueforseprafilmthatcanbepracticedwitha5mmtrocar
AT shiotamitsuru newtechniqueforseprafilmthatcanbepracticedwitha5mmtrocar