Cargando…
A New Technique for Seprafilm(®) That Can Be Practiced with a 5-mm Trocar
Seprafilm(®) is an adhesion barrier sheet. However, it is difficult to handle it through a 5-mm trocar. We have devised a method of applying Seprafilm(®) safely and reliably through a 5-mm trocar by using a holder that comes with the film. We practiced this method in three cases of total laparoscopi...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Wolters Kluwer - Medknow
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8384026/ https://www.ncbi.nlm.nih.gov/pubmed/34485062 http://dx.doi.org/10.4103/GMIT.GMIT_36_20 |
_version_ | 1783741841644978176 |
---|---|
author | Sano, Rikiya Ota, Yoshiaki Tanaka, Tamaki Suzuki, Soichiro Shimoya, Koichiro Shiota, Mitsuru |
author_facet | Sano, Rikiya Ota, Yoshiaki Tanaka, Tamaki Suzuki, Soichiro Shimoya, Koichiro Shiota, Mitsuru |
author_sort | Sano, Rikiya |
collection | PubMed |
description | Seprafilm(®) is an adhesion barrier sheet. However, it is difficult to handle it through a 5-mm trocar. We have devised a method of applying Seprafilm(®) safely and reliably through a 5-mm trocar by using a holder that comes with the film. We practiced this method in three cases of total laparoscopic hysterectomy for uterine leiomyoma. The quarter-pack is cut into three pieces. The film placed on the holder sheet was rolled up with forceps (or wrapped around forceps) and inserted into a 5 mm trocar. After application, the center of the short axis of the holder was pinched with a grasping forceps, and the holder was drawn out of the body through the trocar. Of the 36 pieces placed, Seprafilm(®) broke only in once. Insertion was successful in 100%, and the holder was successfully retrieved through the trocar in 92% (33/36) of the cases. The holder may be easily retrieved after application. This technique represents an extremely simple versatile application method in operations in which only 5-mm trocars can be used. |
format | Online Article Text |
id | pubmed-8384026 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Wolters Kluwer - Medknow |
record_format | MEDLINE/PubMed |
spelling | pubmed-83840262021-09-02 A New Technique for Seprafilm(®) That Can Be Practiced with a 5-mm Trocar Sano, Rikiya Ota, Yoshiaki Tanaka, Tamaki Suzuki, Soichiro Shimoya, Koichiro Shiota, Mitsuru Gynecol Minim Invasive Ther Short Communication Seprafilm(®) is an adhesion barrier sheet. However, it is difficult to handle it through a 5-mm trocar. We have devised a method of applying Seprafilm(®) safely and reliably through a 5-mm trocar by using a holder that comes with the film. We practiced this method in three cases of total laparoscopic hysterectomy for uterine leiomyoma. The quarter-pack is cut into three pieces. The film placed on the holder sheet was rolled up with forceps (or wrapped around forceps) and inserted into a 5 mm trocar. After application, the center of the short axis of the holder was pinched with a grasping forceps, and the holder was drawn out of the body through the trocar. Of the 36 pieces placed, Seprafilm(®) broke only in once. Insertion was successful in 100%, and the holder was successfully retrieved through the trocar in 92% (33/36) of the cases. The holder may be easily retrieved after application. This technique represents an extremely simple versatile application method in operations in which only 5-mm trocars can be used. Wolters Kluwer - Medknow 2021-08-03 /pmc/articles/PMC8384026/ /pubmed/34485062 http://dx.doi.org/10.4103/GMIT.GMIT_36_20 Text en Copyright: © 2021 Gynecology and Minimally Invasive Therapy https://creativecommons.org/licenses/by-nc-sa/4.0/This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms. |
spellingShingle | Short Communication Sano, Rikiya Ota, Yoshiaki Tanaka, Tamaki Suzuki, Soichiro Shimoya, Koichiro Shiota, Mitsuru A New Technique for Seprafilm(®) That Can Be Practiced with a 5-mm Trocar |
title | A New Technique for Seprafilm(®) That Can Be Practiced with a 5-mm Trocar |
title_full | A New Technique for Seprafilm(®) That Can Be Practiced with a 5-mm Trocar |
title_fullStr | A New Technique for Seprafilm(®) That Can Be Practiced with a 5-mm Trocar |
title_full_unstemmed | A New Technique for Seprafilm(®) That Can Be Practiced with a 5-mm Trocar |
title_short | A New Technique for Seprafilm(®) That Can Be Practiced with a 5-mm Trocar |
title_sort | new technique for seprafilm(®) that can be practiced with a 5-mm trocar |
topic | Short Communication |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8384026/ https://www.ncbi.nlm.nih.gov/pubmed/34485062 http://dx.doi.org/10.4103/GMIT.GMIT_36_20 |
work_keys_str_mv | AT sanorikiya anewtechniqueforseprafilmthatcanbepracticedwitha5mmtrocar AT otayoshiaki anewtechniqueforseprafilmthatcanbepracticedwitha5mmtrocar AT tanakatamaki anewtechniqueforseprafilmthatcanbepracticedwitha5mmtrocar AT suzukisoichiro anewtechniqueforseprafilmthatcanbepracticedwitha5mmtrocar AT shimoyakoichiro anewtechniqueforseprafilmthatcanbepracticedwitha5mmtrocar AT shiotamitsuru anewtechniqueforseprafilmthatcanbepracticedwitha5mmtrocar AT sanorikiya newtechniqueforseprafilmthatcanbepracticedwitha5mmtrocar AT otayoshiaki newtechniqueforseprafilmthatcanbepracticedwitha5mmtrocar AT tanakatamaki newtechniqueforseprafilmthatcanbepracticedwitha5mmtrocar AT suzukisoichiro newtechniqueforseprafilmthatcanbepracticedwitha5mmtrocar AT shimoyakoichiro newtechniqueforseprafilmthatcanbepracticedwitha5mmtrocar AT shiotamitsuru newtechniqueforseprafilmthatcanbepracticedwitha5mmtrocar |