Cargando…

Assessment of Patient Satisfaction with On-Site Point-of-Care Hemoglobin A1c Testing: An Observational Study

INTRODUCTION: Poor glycemic control is a serious challenge in successful diabetes management. Given the low adherence and compliance with HbA1c testing frequency and the corresponding delay in the appropriate medication adjustment, point-of-care testing (POCT) for HbA1c provides an opportunity for b...

Descripción completa

Detalles Bibliográficos
Autores principales: Al Hayek, Ayman A., Al-Saeed, Abdulghani H., Alzahrani, Wael M., Al Dawish, Mohamed A.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Healthcare 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8384983/
https://www.ncbi.nlm.nih.gov/pubmed/34363602
http://dx.doi.org/10.1007/s13300-021-01126-7
_version_ 1783742005067644928
author Al Hayek, Ayman A.
Al-Saeed, Abdulghani H.
Alzahrani, Wael M.
Al Dawish, Mohamed A.
author_facet Al Hayek, Ayman A.
Al-Saeed, Abdulghani H.
Alzahrani, Wael M.
Al Dawish, Mohamed A.
author_sort Al Hayek, Ayman A.
collection PubMed
description INTRODUCTION: Poor glycemic control is a serious challenge in successful diabetes management. Given the low adherence and compliance with HbA1c testing frequency and the corresponding delay in the appropriate medication adjustment, point-of-care testing (POCT) for HbA1c provides an opportunity for better control of diabetes and higher patient satisfaction. The data with this regard are limited in Saudi Arabia. Therefore, we aimed to assess the level of patient satisfaction associated with the POCT service implementation for HbA1c and evaluate the differences between the number of requested and conducted HbA1c tests before and after POCT implementation and its effect on glycemic control in Saudi clinical practice. METHODS: We conducted a single-center ambispective descriptive cohort study in Riyadh, Saudi Arabia. This study had two phases: the retrospective phase (January 2017 to December 2017) and the prospective phase (January 2018 to December 2018). Patient satisfaction was assessed using the patient satisfaction questionnaire short form (PSQ-18) and on-site HbA1c point-of-care testing (HbA1c-POCT) satisfaction questionnaire. RESULTS: This study included 75 patients with diabetes (37% type 1, 63% type 2) with a mean age of 44.35 (± 17.97) years. The adherence to physician recommendations for HbA1c testing frequency increased from 24% to 85% (before and after POCT implementation, respectively). High levels of satisfaction across seven dimensions of PSQ-18 (77–88%) were reported towards the provided healthcare service after POCT implementation. Furthermore, a high level of agreement on the statements of the on-site HbA1c-POCT satisfaction questionnaire was also observed. Finally, the mean HbA1c level has significantly improved after POCT implementation compared to the traditional HbA1c laboratory testing before POCT implementation [8.34 ± 0.67 and 8.06 ± 0.62, respectively, p < 0.001). CONCLUSION: HbA1c testing at POCT improved adherence to recommendations for HbA1c testing frequency for better glycemic control and higher patient satisfaction. POCT reduces turnaround time, improves glycemic control, and facilitates the decision-making process. HbA1c measurement with POC devices is recommended to be implemented in diabetes treatment centers. All of the described benefits of POCT come together to make HbA1c testing the most common procedure for diabetes management at the point of care. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s13300-021-01126-7.
format Online
Article
Text
id pubmed-8384983
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Springer Healthcare
record_format MEDLINE/PubMed
spelling pubmed-83849832021-09-09 Assessment of Patient Satisfaction with On-Site Point-of-Care Hemoglobin A1c Testing: An Observational Study Al Hayek, Ayman A. Al-Saeed, Abdulghani H. Alzahrani, Wael M. Al Dawish, Mohamed A. Diabetes Ther Original Research INTRODUCTION: Poor glycemic control is a serious challenge in successful diabetes management. Given the low adherence and compliance with HbA1c testing frequency and the corresponding delay in the appropriate medication adjustment, point-of-care testing (POCT) for HbA1c provides an opportunity for better control of diabetes and higher patient satisfaction. The data with this regard are limited in Saudi Arabia. Therefore, we aimed to assess the level of patient satisfaction associated with the POCT service implementation for HbA1c and evaluate the differences between the number of requested and conducted HbA1c tests before and after POCT implementation and its effect on glycemic control in Saudi clinical practice. METHODS: We conducted a single-center ambispective descriptive cohort study in Riyadh, Saudi Arabia. This study had two phases: the retrospective phase (January 2017 to December 2017) and the prospective phase (January 2018 to December 2018). Patient satisfaction was assessed using the patient satisfaction questionnaire short form (PSQ-18) and on-site HbA1c point-of-care testing (HbA1c-POCT) satisfaction questionnaire. RESULTS: This study included 75 patients with diabetes (37% type 1, 63% type 2) with a mean age of 44.35 (± 17.97) years. The adherence to physician recommendations for HbA1c testing frequency increased from 24% to 85% (before and after POCT implementation, respectively). High levels of satisfaction across seven dimensions of PSQ-18 (77–88%) were reported towards the provided healthcare service after POCT implementation. Furthermore, a high level of agreement on the statements of the on-site HbA1c-POCT satisfaction questionnaire was also observed. Finally, the mean HbA1c level has significantly improved after POCT implementation compared to the traditional HbA1c laboratory testing before POCT implementation [8.34 ± 0.67 and 8.06 ± 0.62, respectively, p < 0.001). CONCLUSION: HbA1c testing at POCT improved adherence to recommendations for HbA1c testing frequency for better glycemic control and higher patient satisfaction. POCT reduces turnaround time, improves glycemic control, and facilitates the decision-making process. HbA1c measurement with POC devices is recommended to be implemented in diabetes treatment centers. All of the described benefits of POCT come together to make HbA1c testing the most common procedure for diabetes management at the point of care. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s13300-021-01126-7. Springer Healthcare 2021-08-07 2021-09 /pmc/articles/PMC8384983/ /pubmed/34363602 http://dx.doi.org/10.1007/s13300-021-01126-7 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by-nc/4.0/Open Access This article is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License, which permits any non-commercial use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by-nc/4.0/ (https://creativecommons.org/licenses/by-nc/4.0/) .
spellingShingle Original Research
Al Hayek, Ayman A.
Al-Saeed, Abdulghani H.
Alzahrani, Wael M.
Al Dawish, Mohamed A.
Assessment of Patient Satisfaction with On-Site Point-of-Care Hemoglobin A1c Testing: An Observational Study
title Assessment of Patient Satisfaction with On-Site Point-of-Care Hemoglobin A1c Testing: An Observational Study
title_full Assessment of Patient Satisfaction with On-Site Point-of-Care Hemoglobin A1c Testing: An Observational Study
title_fullStr Assessment of Patient Satisfaction with On-Site Point-of-Care Hemoglobin A1c Testing: An Observational Study
title_full_unstemmed Assessment of Patient Satisfaction with On-Site Point-of-Care Hemoglobin A1c Testing: An Observational Study
title_short Assessment of Patient Satisfaction with On-Site Point-of-Care Hemoglobin A1c Testing: An Observational Study
title_sort assessment of patient satisfaction with on-site point-of-care hemoglobin a1c testing: an observational study
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8384983/
https://www.ncbi.nlm.nih.gov/pubmed/34363602
http://dx.doi.org/10.1007/s13300-021-01126-7
work_keys_str_mv AT alhayekaymana assessmentofpatientsatisfactionwithonsitepointofcarehemoglobina1ctestinganobservationalstudy
AT alsaeedabdulghanih assessmentofpatientsatisfactionwithonsitepointofcarehemoglobina1ctestinganobservationalstudy
AT alzahraniwaelm assessmentofpatientsatisfactionwithonsitepointofcarehemoglobina1ctestinganobservationalstudy
AT aldawishmohameda assessmentofpatientsatisfactionwithonsitepointofcarehemoglobina1ctestinganobservationalstudy