Cargando…

Assessment of tissue oxygen tension: comparison of dynamic fluorescence quenching and polarographic electrode technique

INTRODUCTION AND METHODS: Dynamic fluorescence quenching is a technique that may overcome some of the limitations associated with measurement of tissue partial oxygen tension (PO(2)). We compared this technique with a polarographic Eppendorf needle electrode method using a saline tonometer in which...

Descripción completa

Detalles Bibliográficos
Autores principales: Shaw, Andrew D, Li, Zheng, Thomas, Zach, Stevens, Craig W
Formato: Texto
Lenguaje:English
Publicado: BioMed Central 2002
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC83850/
https://www.ncbi.nlm.nih.gov/pubmed/11940270
_version_ 1782120184704663552
author Shaw, Andrew D
Li, Zheng
Thomas, Zach
Stevens, Craig W
author_facet Shaw, Andrew D
Li, Zheng
Thomas, Zach
Stevens, Craig W
author_sort Shaw, Andrew D
collection PubMed
description INTRODUCTION AND METHODS: Dynamic fluorescence quenching is a technique that may overcome some of the limitations associated with measurement of tissue partial oxygen tension (PO(2)). We compared this technique with a polarographic Eppendorf needle electrode method using a saline tonometer in which the PO(2) could be controlled. We also tested the fluorescence quenching system in a rodent model of skeletal muscle ischemiahypoxia. RESULTS: Both systems measured PO(2) accurately in the tonometer, and there was excellent correlation between them (r(2) = 0.99). The polarographic system exhibited proportional bias that was not evident with the fluorescence method. In vivo, the fluorescence quenching technique provided a readily recordable signal that varied as expected. DISCUSSION: Measurement of tissue PO(2) using fluorescence quenching is at least as accurate as measurement using the Eppendorf needle electrode in vitro, and may prove useful in vivo for assessment of tissue oxygenation.
format Text
id pubmed-83850
institution National Center for Biotechnology Information
language English
publishDate 2002
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-838502002-03-15 Assessment of tissue oxygen tension: comparison of dynamic fluorescence quenching and polarographic electrode technique Shaw, Andrew D Li, Zheng Thomas, Zach Stevens, Craig W Crit Care Research INTRODUCTION AND METHODS: Dynamic fluorescence quenching is a technique that may overcome some of the limitations associated with measurement of tissue partial oxygen tension (PO(2)). We compared this technique with a polarographic Eppendorf needle electrode method using a saline tonometer in which the PO(2) could be controlled. We also tested the fluorescence quenching system in a rodent model of skeletal muscle ischemiahypoxia. RESULTS: Both systems measured PO(2) accurately in the tonometer, and there was excellent correlation between them (r(2) = 0.99). The polarographic system exhibited proportional bias that was not evident with the fluorescence method. In vivo, the fluorescence quenching technique provided a readily recordable signal that varied as expected. DISCUSSION: Measurement of tissue PO(2) using fluorescence quenching is at least as accurate as measurement using the Eppendorf needle electrode in vitro, and may prove useful in vivo for assessment of tissue oxygenation. BioMed Central 2002 2002-01-10 /pmc/articles/PMC83850/ /pubmed/11940270 Text en Copyright © 2002 BioMed Central Ltd
spellingShingle Research
Shaw, Andrew D
Li, Zheng
Thomas, Zach
Stevens, Craig W
Assessment of tissue oxygen tension: comparison of dynamic fluorescence quenching and polarographic electrode technique
title Assessment of tissue oxygen tension: comparison of dynamic fluorescence quenching and polarographic electrode technique
title_full Assessment of tissue oxygen tension: comparison of dynamic fluorescence quenching and polarographic electrode technique
title_fullStr Assessment of tissue oxygen tension: comparison of dynamic fluorescence quenching and polarographic electrode technique
title_full_unstemmed Assessment of tissue oxygen tension: comparison of dynamic fluorescence quenching and polarographic electrode technique
title_short Assessment of tissue oxygen tension: comparison of dynamic fluorescence quenching and polarographic electrode technique
title_sort assessment of tissue oxygen tension: comparison of dynamic fluorescence quenching and polarographic electrode technique
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC83850/
https://www.ncbi.nlm.nih.gov/pubmed/11940270
work_keys_str_mv AT shawandrewd assessmentoftissueoxygentensioncomparisonofdynamicfluorescencequenchingandpolarographicelectrodetechnique
AT lizheng assessmentoftissueoxygentensioncomparisonofdynamicfluorescencequenchingandpolarographicelectrodetechnique
AT thomaszach assessmentoftissueoxygentensioncomparisonofdynamicfluorescencequenchingandpolarographicelectrodetechnique
AT stevenscraigw assessmentoftissueoxygentensioncomparisonofdynamicfluorescencequenchingandpolarographicelectrodetechnique