Numerical Models Can Assist Choice of an Aortic Phantom for In Vitro Testing

(1) Background: The realization of appropriate aortic replicas for in vitro experiments requires a suitable choice of both the material and geometry. The matching between the grade of details of the geometry and the mechanical response of the materials is an open issue that deserves attention. (2) M...

Descripción completa

Detalles Bibliográficos
Autores principales: Comunale, Giulia, Di Micco, Luigi, Boso, Daniela Paola, Susin, Francesca Maria, Peruzzo, Paolo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8389249/
https://www.ncbi.nlm.nih.gov/pubmed/34436104
http://dx.doi.org/10.3390/bioengineering8080101
_version_ 1783742816559562752
author Comunale, Giulia
Di Micco, Luigi
Boso, Daniela Paola
Susin, Francesca Maria
Peruzzo, Paolo
author_facet Comunale, Giulia
Di Micco, Luigi
Boso, Daniela Paola
Susin, Francesca Maria
Peruzzo, Paolo
author_sort Comunale, Giulia
collection PubMed
description (1) Background: The realization of appropriate aortic replicas for in vitro experiments requires a suitable choice of both the material and geometry. The matching between the grade of details of the geometry and the mechanical response of the materials is an open issue that deserves attention. (2) Methods: To explore this issue, we performed a series of Fluid–Structure Interaction simulations, which compared the dynamics of three aortic models. Specifically, we reproduced a patient-specific geometry with a wall of biological tissue or silicone, and a parametric geometry based on in vivo data made in silicone. The biological tissue and the silicone were modeled with a fiber-oriented anisotropic and isotropic hyperelastic model, respectively. (3) Results: Clearly, both the aorta’s geometry and its constitutive material contribute to the determination of the aortic arch deformation; specifically, the parametric aorta exhibits a strain field similar to the patient-specific model with biological tissue. On the contrary, the local geometry affects the flow velocity distribution quite a lot, although it plays a minor role in the helicity along the arch. (4) Conclusions: The use of a patient-specific prototype in silicone does not a priori ensure a satisfactory reproducibility of the real aorta dynamics. Furthermore, the present simulations suggest that the realization of a simplified replica with the same compliance of the real aorta is able to mimic the overall behavior of the vessel.
format Online
Article
Text
id pubmed-8389249
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-83892492021-08-27 Numerical Models Can Assist Choice of an Aortic Phantom for In Vitro Testing Comunale, Giulia Di Micco, Luigi Boso, Daniela Paola Susin, Francesca Maria Peruzzo, Paolo Bioengineering (Basel) Article (1) Background: The realization of appropriate aortic replicas for in vitro experiments requires a suitable choice of both the material and geometry. The matching between the grade of details of the geometry and the mechanical response of the materials is an open issue that deserves attention. (2) Methods: To explore this issue, we performed a series of Fluid–Structure Interaction simulations, which compared the dynamics of three aortic models. Specifically, we reproduced a patient-specific geometry with a wall of biological tissue or silicone, and a parametric geometry based on in vivo data made in silicone. The biological tissue and the silicone were modeled with a fiber-oriented anisotropic and isotropic hyperelastic model, respectively. (3) Results: Clearly, both the aorta’s geometry and its constitutive material contribute to the determination of the aortic arch deformation; specifically, the parametric aorta exhibits a strain field similar to the patient-specific model with biological tissue. On the contrary, the local geometry affects the flow velocity distribution quite a lot, although it plays a minor role in the helicity along the arch. (4) Conclusions: The use of a patient-specific prototype in silicone does not a priori ensure a satisfactory reproducibility of the real aorta dynamics. Furthermore, the present simulations suggest that the realization of a simplified replica with the same compliance of the real aorta is able to mimic the overall behavior of the vessel. MDPI 2021-07-21 /pmc/articles/PMC8389249/ /pubmed/34436104 http://dx.doi.org/10.3390/bioengineering8080101 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Comunale, Giulia
Di Micco, Luigi
Boso, Daniela Paola
Susin, Francesca Maria
Peruzzo, Paolo
Numerical Models Can Assist Choice of an Aortic Phantom for In Vitro Testing
title Numerical Models Can Assist Choice of an Aortic Phantom for In Vitro Testing
title_full Numerical Models Can Assist Choice of an Aortic Phantom for In Vitro Testing
title_fullStr Numerical Models Can Assist Choice of an Aortic Phantom for In Vitro Testing
title_full_unstemmed Numerical Models Can Assist Choice of an Aortic Phantom for In Vitro Testing
title_short Numerical Models Can Assist Choice of an Aortic Phantom for In Vitro Testing
title_sort numerical models can assist choice of an aortic phantom for in vitro testing
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8389249/
https://www.ncbi.nlm.nih.gov/pubmed/34436104
http://dx.doi.org/10.3390/bioengineering8080101
work_keys_str_mv AT comunalegiulia numericalmodelscanassistchoiceofanaorticphantomforinvitrotesting
AT dimiccoluigi numericalmodelscanassistchoiceofanaorticphantomforinvitrotesting
AT bosodanielapaola numericalmodelscanassistchoiceofanaorticphantomforinvitrotesting
AT susinfrancescamaria numericalmodelscanassistchoiceofanaorticphantomforinvitrotesting
AT peruzzopaolo numericalmodelscanassistchoiceofanaorticphantomforinvitrotesting