Cargando…
Use of Continuous Positive Airway Pressure (CPAP) to Limit Diaphragm Motion—A Novel Approach for Definitive Radiation Therapy for Inoperable Pleural Mesothelioma: A Pilot Study
SIMPLE SUMMARY: Radiotherapy is an important part of the multimodality approach to treating malignant pleural mesothelioma. In recent studies there is a new trend to treat patients with intact lungs instead of following surgery. This treatment creates significant concerns regarding lung toxicity. We...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8389276/ https://www.ncbi.nlm.nih.gov/pubmed/34439944 http://dx.doi.org/10.3390/biology10080711 |
Sumario: | SIMPLE SUMMARY: Radiotherapy is an important part of the multimodality approach to treating malignant pleural mesothelioma. In recent studies there is a new trend to treat patients with intact lungs instead of following surgery. This treatment creates significant concerns regarding lung toxicity. We describe two methods to reduce that toxicity. One is the use of constant pulmonary airway pressure (CPAP) to inflate the lungs during treatment. The second is utilizing a novel method of planning and delivering radiotherapy called volumetric modulated arc therapy (VMAT). ABSTRACT: Malignant pleural mesothelioma (MPM) is a deadly disease and radiotherapy (RT) plays an important role in its management. Recent developments in technique have made it is possible to deliver RT to MPM in the intact lung. However, it is imperative to reduce normal lung doses. We present a pilot study examining the use of CPAP and VMAT radiotherapy to reduce toxicity when treating MPM, involving three consecutive patients with MPM, not amenable to surgery, who were treated according to Helsinki committee approval. Patients were simulated using four-dimentional CT simulation with the assistance of CPAP lung inflation, then were treated using both IMRT and VMAT techniques. Radiation lung dose was optimized based on accepted lung dose constraints. Patients were followed for toxicity as well as local control and survival. Results: Three patients were treated with CPAP-based IMRT treatment. These patients tolerated the treatment and DVH constraints were able to be met. The comparison plans among the four VMAT arcs and the IMRT static field treatment were able to accomplish the treatment planning objectives without significant advantages with either technique. The treatment combined with CPAP reduced the normal lung dose in MPM patients with intact lungs. This technique is worthy of further investigation. |
---|