Cargando…
Efficacy of the new β-D-glucan measurement kit for diagnosing invasive fungal infections, as compared with that of four conventional kits
BACKGROUND: Each of the currently available (1→3)-β-D-glucan (BDG) measurement kits follows a different measurement method and cut-off value. Comparisons of diagnostic performance for invasive fungal infections (IFIs) are desirable. Additionally, ecological considerations are becoming increasingly i...
Autores principales: | , , , , , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8389481/ https://www.ncbi.nlm.nih.gov/pubmed/34437556 http://dx.doi.org/10.1371/journal.pone.0255172 |
_version_ | 1783742868792279040 |
---|---|
author | Bamba, Yuuki Nagano, Kei Moro, Hiroshi Ogata, Hideyuki Hakamata, Mariko Shibata, Satoshi Koizumi, Takeshi Aoki, Nobumasa Ohshima, Yasuyoshi Watanabe, Satoshi Nakamura, Takeshi Kobayashi, Sugako Hoshiyama, Yoshiki Koya, Toshiyuki Takada, Toshinori Kikuchi, Toshiaki |
author_facet | Bamba, Yuuki Nagano, Kei Moro, Hiroshi Ogata, Hideyuki Hakamata, Mariko Shibata, Satoshi Koizumi, Takeshi Aoki, Nobumasa Ohshima, Yasuyoshi Watanabe, Satoshi Nakamura, Takeshi Kobayashi, Sugako Hoshiyama, Yoshiki Koya, Toshiyuki Takada, Toshinori Kikuchi, Toshiaki |
author_sort | Bamba, Yuuki |
collection | PubMed |
description | BACKGROUND: Each of the currently available (1→3)-β-D-glucan (BDG) measurement kits follows a different measurement method and cut-off value. Comparisons of diagnostic performance for invasive fungal infections (IFIs) are desirable. Additionally, ecological considerations are becoming increasingly important in the development of new measurement kits. METHODS: The plasma BDG levels in clinical samples were measured using the following currently available kits: the Fungitec G test MKII, the Fungitec G test ES, Fungitell, the β-Glucan test Wako, and the newly developed Wako kit (Wako-Eu). Wako-Eu uses a pre-treatment solution that conforms to European regulations for the registration, evaluation, authorisation, and restriction of chemicals. The values obtained for the samples using each kit were studied and compared. RESULTS: Of the 165 patients evaluated, 12 had IFIs, including pneumocystis pneumonia, aspergillosis, and candidiasis. BDG values obtained using the kits were moderately correlated with each other. Clinical diagnoses of the evaluated cases indicated that 21 false positives were diagnosed by at least one kit. The sensitivity of the Fungitell kit was relatively low, but those of the other four were over 90%. The specificity was above 90% for all kits. For positive predictive value, the Wako and the Wako-Eu methods were superior to the others owing to fewer false positive results. CONCLUSIONS: The newly developed Wako-Eu method, which considers ecological concerns, shows diagnostic performance equivalent to that of its predecessor. To improve the diagnostic accuracy of IFIs, it is necessary to interpret the results carefully, giving due consideration to the characteristics of each measurement kit. |
format | Online Article Text |
id | pubmed-8389481 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-83894812021-08-27 Efficacy of the new β-D-glucan measurement kit for diagnosing invasive fungal infections, as compared with that of four conventional kits Bamba, Yuuki Nagano, Kei Moro, Hiroshi Ogata, Hideyuki Hakamata, Mariko Shibata, Satoshi Koizumi, Takeshi Aoki, Nobumasa Ohshima, Yasuyoshi Watanabe, Satoshi Nakamura, Takeshi Kobayashi, Sugako Hoshiyama, Yoshiki Koya, Toshiyuki Takada, Toshinori Kikuchi, Toshiaki PLoS One Research Article BACKGROUND: Each of the currently available (1→3)-β-D-glucan (BDG) measurement kits follows a different measurement method and cut-off value. Comparisons of diagnostic performance for invasive fungal infections (IFIs) are desirable. Additionally, ecological considerations are becoming increasingly important in the development of new measurement kits. METHODS: The plasma BDG levels in clinical samples were measured using the following currently available kits: the Fungitec G test MKII, the Fungitec G test ES, Fungitell, the β-Glucan test Wako, and the newly developed Wako kit (Wako-Eu). Wako-Eu uses a pre-treatment solution that conforms to European regulations for the registration, evaluation, authorisation, and restriction of chemicals. The values obtained for the samples using each kit were studied and compared. RESULTS: Of the 165 patients evaluated, 12 had IFIs, including pneumocystis pneumonia, aspergillosis, and candidiasis. BDG values obtained using the kits were moderately correlated with each other. Clinical diagnoses of the evaluated cases indicated that 21 false positives were diagnosed by at least one kit. The sensitivity of the Fungitell kit was relatively low, but those of the other four were over 90%. The specificity was above 90% for all kits. For positive predictive value, the Wako and the Wako-Eu methods were superior to the others owing to fewer false positive results. CONCLUSIONS: The newly developed Wako-Eu method, which considers ecological concerns, shows diagnostic performance equivalent to that of its predecessor. To improve the diagnostic accuracy of IFIs, it is necessary to interpret the results carefully, giving due consideration to the characteristics of each measurement kit. Public Library of Science 2021-08-26 /pmc/articles/PMC8389481/ /pubmed/34437556 http://dx.doi.org/10.1371/journal.pone.0255172 Text en © 2021 Bamba et al https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. |
spellingShingle | Research Article Bamba, Yuuki Nagano, Kei Moro, Hiroshi Ogata, Hideyuki Hakamata, Mariko Shibata, Satoshi Koizumi, Takeshi Aoki, Nobumasa Ohshima, Yasuyoshi Watanabe, Satoshi Nakamura, Takeshi Kobayashi, Sugako Hoshiyama, Yoshiki Koya, Toshiyuki Takada, Toshinori Kikuchi, Toshiaki Efficacy of the new β-D-glucan measurement kit for diagnosing invasive fungal infections, as compared with that of four conventional kits |
title | Efficacy of the new β-D-glucan measurement kit for diagnosing invasive fungal infections, as compared with that of four conventional kits |
title_full | Efficacy of the new β-D-glucan measurement kit for diagnosing invasive fungal infections, as compared with that of four conventional kits |
title_fullStr | Efficacy of the new β-D-glucan measurement kit for diagnosing invasive fungal infections, as compared with that of four conventional kits |
title_full_unstemmed | Efficacy of the new β-D-glucan measurement kit for diagnosing invasive fungal infections, as compared with that of four conventional kits |
title_short | Efficacy of the new β-D-glucan measurement kit for diagnosing invasive fungal infections, as compared with that of four conventional kits |
title_sort | efficacy of the new β-d-glucan measurement kit for diagnosing invasive fungal infections, as compared with that of four conventional kits |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8389481/ https://www.ncbi.nlm.nih.gov/pubmed/34437556 http://dx.doi.org/10.1371/journal.pone.0255172 |
work_keys_str_mv | AT bambayuuki efficacyofthenewbdglucanmeasurementkitfordiagnosinginvasivefungalinfectionsascomparedwiththatoffourconventionalkits AT naganokei efficacyofthenewbdglucanmeasurementkitfordiagnosinginvasivefungalinfectionsascomparedwiththatoffourconventionalkits AT morohiroshi efficacyofthenewbdglucanmeasurementkitfordiagnosinginvasivefungalinfectionsascomparedwiththatoffourconventionalkits AT ogatahideyuki efficacyofthenewbdglucanmeasurementkitfordiagnosinginvasivefungalinfectionsascomparedwiththatoffourconventionalkits AT hakamatamariko efficacyofthenewbdglucanmeasurementkitfordiagnosinginvasivefungalinfectionsascomparedwiththatoffourconventionalkits AT shibatasatoshi efficacyofthenewbdglucanmeasurementkitfordiagnosinginvasivefungalinfectionsascomparedwiththatoffourconventionalkits AT koizumitakeshi efficacyofthenewbdglucanmeasurementkitfordiagnosinginvasivefungalinfectionsascomparedwiththatoffourconventionalkits AT aokinobumasa efficacyofthenewbdglucanmeasurementkitfordiagnosinginvasivefungalinfectionsascomparedwiththatoffourconventionalkits AT ohshimayasuyoshi efficacyofthenewbdglucanmeasurementkitfordiagnosinginvasivefungalinfectionsascomparedwiththatoffourconventionalkits AT watanabesatoshi efficacyofthenewbdglucanmeasurementkitfordiagnosinginvasivefungalinfectionsascomparedwiththatoffourconventionalkits AT nakamuratakeshi efficacyofthenewbdglucanmeasurementkitfordiagnosinginvasivefungalinfectionsascomparedwiththatoffourconventionalkits AT kobayashisugako efficacyofthenewbdglucanmeasurementkitfordiagnosinginvasivefungalinfectionsascomparedwiththatoffourconventionalkits AT hoshiyamayoshiki efficacyofthenewbdglucanmeasurementkitfordiagnosinginvasivefungalinfectionsascomparedwiththatoffourconventionalkits AT koyatoshiyuki efficacyofthenewbdglucanmeasurementkitfordiagnosinginvasivefungalinfectionsascomparedwiththatoffourconventionalkits AT takadatoshinori efficacyofthenewbdglucanmeasurementkitfordiagnosinginvasivefungalinfectionsascomparedwiththatoffourconventionalkits AT kikuchitoshiaki efficacyofthenewbdglucanmeasurementkitfordiagnosinginvasivefungalinfectionsascomparedwiththatoffourconventionalkits |