Cargando…

Implementation of a zero fluoroscopic workflow using a simplified intracardiac echocardiography guided method for catheter ablation of atrial fibrillation, including repeat procedures

OBJECTIVE: Pulmonary vein isolation (PVI) is the cornerstone of the interventional treatment of atrial fibrillation (AF). Traditionally, during these procedures the catheters are guided by fluoroscopy, which poses a risk to the patient and staff by ionizing radiation. Our aim was to describe our exp...

Descripción completa

Detalles Bibliográficos
Autores principales: Tahin, Tamas, Riba, Adam, Nemeth, Barnabas, Arvai, Ferenc, Lupkovics, Geza, Szeplaki, Gabor, Geller, Laszlo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8390247/
https://www.ncbi.nlm.nih.gov/pubmed/34433424
http://dx.doi.org/10.1186/s12872-021-02219-8
_version_ 1783743051467849728
author Tahin, Tamas
Riba, Adam
Nemeth, Barnabas
Arvai, Ferenc
Lupkovics, Geza
Szeplaki, Gabor
Geller, Laszlo
author_facet Tahin, Tamas
Riba, Adam
Nemeth, Barnabas
Arvai, Ferenc
Lupkovics, Geza
Szeplaki, Gabor
Geller, Laszlo
author_sort Tahin, Tamas
collection PubMed
description OBJECTIVE: Pulmonary vein isolation (PVI) is the cornerstone of the interventional treatment of atrial fibrillation (AF). Traditionally, during these procedures the catheters are guided by fluoroscopy, which poses a risk to the patient and staff by ionizing radiation. Our aim was to describe our experience in the implementation of an intracardiac echocardiography (ICE) guided zero fluoroscopic (ZF) ablation approach to our routine clinical practice. METHODS: We developed a simplified ICE guided technique to perform ablation procedures for AF, with the aid of a 3D electroanatomical mapping system. The workflow was implemented in two phases: (1) the Introductory phase, where the first 16 ZF PVIs were compared with 16 cases performed with fluoroscopy and (2) the Extension phase, where 71 consecutive patients (including repeat procedures) with ZF approach were included. Standard PVI (and redoPVI) procedures were performed, data on feasibility of the ZF approach, complications, acute and 1-year success rates were collected. RESULTS: In the Introductory phase, 94% of the procedures could be performed with complete ZF with a median procedure time of 77.5 (73.5–83) minutes. In one case fluoroscopy was used to guide the ICE catheter to the atrium. There was no difference in the complication, acute and 1-year success rates, compared with fluoroscopy guided procedures. In the Extension phase, 97% of the procedures could be completed with complete ZF. In one case fluoroscopy was used to guide the transseptal puncture and in another to position the ICE catheter. Acute success of PVI was achieved in all cases, 64.4% patients were arrhythmia free at 1-year. Acute major complications were observed in 4 cases, all of these occurred in the redo PVI group and consisted of 2 tamponades, 1 transient ischemic attack and 1 pseudoaneurysm at the puncture site. The procedures were carried out by all members of the electrophysiology unit in the Extension phase, including less experienced operators and electrophysiology fellows (3 physicians) under the supervision of the senior electrophysiologist. Consequently, procedure times became longer [90 (75–105) vs 77.5 (73.5–85) min, p = 0.014]. CONCLUSIONS: According to our results, a ZF workflow of AF ablations can be successfully implemented into the routine practice of an electrophysiology laboratory, without compromising safety and effectivity.
format Online
Article
Text
id pubmed-8390247
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-83902472021-08-27 Implementation of a zero fluoroscopic workflow using a simplified intracardiac echocardiography guided method for catheter ablation of atrial fibrillation, including repeat procedures Tahin, Tamas Riba, Adam Nemeth, Barnabas Arvai, Ferenc Lupkovics, Geza Szeplaki, Gabor Geller, Laszlo BMC Cardiovasc Disord Research OBJECTIVE: Pulmonary vein isolation (PVI) is the cornerstone of the interventional treatment of atrial fibrillation (AF). Traditionally, during these procedures the catheters are guided by fluoroscopy, which poses a risk to the patient and staff by ionizing radiation. Our aim was to describe our experience in the implementation of an intracardiac echocardiography (ICE) guided zero fluoroscopic (ZF) ablation approach to our routine clinical practice. METHODS: We developed a simplified ICE guided technique to perform ablation procedures for AF, with the aid of a 3D electroanatomical mapping system. The workflow was implemented in two phases: (1) the Introductory phase, where the first 16 ZF PVIs were compared with 16 cases performed with fluoroscopy and (2) the Extension phase, where 71 consecutive patients (including repeat procedures) with ZF approach were included. Standard PVI (and redoPVI) procedures were performed, data on feasibility of the ZF approach, complications, acute and 1-year success rates were collected. RESULTS: In the Introductory phase, 94% of the procedures could be performed with complete ZF with a median procedure time of 77.5 (73.5–83) minutes. In one case fluoroscopy was used to guide the ICE catheter to the atrium. There was no difference in the complication, acute and 1-year success rates, compared with fluoroscopy guided procedures. In the Extension phase, 97% of the procedures could be completed with complete ZF. In one case fluoroscopy was used to guide the transseptal puncture and in another to position the ICE catheter. Acute success of PVI was achieved in all cases, 64.4% patients were arrhythmia free at 1-year. Acute major complications were observed in 4 cases, all of these occurred in the redo PVI group and consisted of 2 tamponades, 1 transient ischemic attack and 1 pseudoaneurysm at the puncture site. The procedures were carried out by all members of the electrophysiology unit in the Extension phase, including less experienced operators and electrophysiology fellows (3 physicians) under the supervision of the senior electrophysiologist. Consequently, procedure times became longer [90 (75–105) vs 77.5 (73.5–85) min, p = 0.014]. CONCLUSIONS: According to our results, a ZF workflow of AF ablations can be successfully implemented into the routine practice of an electrophysiology laboratory, without compromising safety and effectivity. BioMed Central 2021-08-26 /pmc/articles/PMC8390247/ /pubmed/34433424 http://dx.doi.org/10.1186/s12872-021-02219-8 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research
Tahin, Tamas
Riba, Adam
Nemeth, Barnabas
Arvai, Ferenc
Lupkovics, Geza
Szeplaki, Gabor
Geller, Laszlo
Implementation of a zero fluoroscopic workflow using a simplified intracardiac echocardiography guided method for catheter ablation of atrial fibrillation, including repeat procedures
title Implementation of a zero fluoroscopic workflow using a simplified intracardiac echocardiography guided method for catheter ablation of atrial fibrillation, including repeat procedures
title_full Implementation of a zero fluoroscopic workflow using a simplified intracardiac echocardiography guided method for catheter ablation of atrial fibrillation, including repeat procedures
title_fullStr Implementation of a zero fluoroscopic workflow using a simplified intracardiac echocardiography guided method for catheter ablation of atrial fibrillation, including repeat procedures
title_full_unstemmed Implementation of a zero fluoroscopic workflow using a simplified intracardiac echocardiography guided method for catheter ablation of atrial fibrillation, including repeat procedures
title_short Implementation of a zero fluoroscopic workflow using a simplified intracardiac echocardiography guided method for catheter ablation of atrial fibrillation, including repeat procedures
title_sort implementation of a zero fluoroscopic workflow using a simplified intracardiac echocardiography guided method for catheter ablation of atrial fibrillation, including repeat procedures
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8390247/
https://www.ncbi.nlm.nih.gov/pubmed/34433424
http://dx.doi.org/10.1186/s12872-021-02219-8
work_keys_str_mv AT tahintamas implementationofazerofluoroscopicworkflowusingasimplifiedintracardiacechocardiographyguidedmethodforcatheterablationofatrialfibrillationincludingrepeatprocedures
AT ribaadam implementationofazerofluoroscopicworkflowusingasimplifiedintracardiacechocardiographyguidedmethodforcatheterablationofatrialfibrillationincludingrepeatprocedures
AT nemethbarnabas implementationofazerofluoroscopicworkflowusingasimplifiedintracardiacechocardiographyguidedmethodforcatheterablationofatrialfibrillationincludingrepeatprocedures
AT arvaiferenc implementationofazerofluoroscopicworkflowusingasimplifiedintracardiacechocardiographyguidedmethodforcatheterablationofatrialfibrillationincludingrepeatprocedures
AT lupkovicsgeza implementationofazerofluoroscopicworkflowusingasimplifiedintracardiacechocardiographyguidedmethodforcatheterablationofatrialfibrillationincludingrepeatprocedures
AT szeplakigabor implementationofazerofluoroscopicworkflowusingasimplifiedintracardiacechocardiographyguidedmethodforcatheterablationofatrialfibrillationincludingrepeatprocedures
AT gellerlaszlo implementationofazerofluoroscopicworkflowusingasimplifiedintracardiacechocardiographyguidedmethodforcatheterablationofatrialfibrillationincludingrepeatprocedures